<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-8116238656716228153</id><updated>2011-12-30T16:40:09.189+03:30</updated><title type='text'>ايمني وبهداشت در برق</title><subtitle type='html'>ايمني وبهداشت در برق</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><link rel='next' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default?start-index=101&amp;max-results=100'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>1094</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5000916112206617298</id><published>2011-12-30T16:39:00.000+03:30</published><updated>2011-12-30T16:40:09.197+03:30</updated><title type='text'>برق گرفتگی هنگام استفاده از ماشین لباسشویی</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;p style="text-align: center;"&gt;&lt;img src="http://www.sansovan.com/UserFiles/Uploads/55-21S.jpg" /&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:100%;"&gt;چند روز پیش در جریان اجرای ممیزی داخلی بود که  اعلام گردید، برای یکی ساکنین منازل کارگری یک کوره آجر پزی حادثه برق  گرفتگی رویداده که بلافاصله به طرف محل حادثه که اطراف شهر بود حرکت کرده ،  وقتی به محل رسیدم فرد برق گرفته در محل نبود، گویا وی را بلافاصله با  خودروی شخصی به بیمارستان منتقل می کنند که متاسفانه این خانم بدشانس در  اثر این برق گرفتگی جانش را از دست می دهد. &lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:100%;"&gt;از  قرار این خانم با یک دستگاه ماشین لباسشویی در رختشوی خانه مشغول شستشوی  لباس بوده که دچار برق گرفتگی می شود. بنا به اظهار خانم های همسایه، ایشان  در رختشوی خانه تنها بوده و هنگام وقوع حادثه فقط صدای جیغ متوفی، آنها را  متوجه موضوع می نماید.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:100%;"&gt;پس از شنیدن اظهارات  همسایه ها و شاهدین به معاینه تاسیسات و تابلوی برق محل پرداخته و سپس  ماشین لباسشویی را بررسی کرده و در شرایط خشک و مرطوب آن را آزمایش نموده و  در نهایت مشخص گردید قسمت های فلزی در دسترس بدنه این ماشین لباسشویی  ولتاژی حدود 105 ولت دارد. بدیهی است که این ولتاژ در شرایط مرطوب رخشتشوی  خانه، بستر مناسبی برای برق گرفتگی می باشد.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:100%;"&gt;  به هر صورت عدم استفاده از سیستم ارتینگ استاندارد و عدم انجام سرویس دوره  ای تجهیزات الکتریکی و از همه مهمتر عدم آگاهی کاربران از مخاطرات برق و  نکات حفاظتی آن، از آن از جمله عوامل بروز این حادثه می باشد.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:100%;"&gt;البته  استفاده از پریز در داخل محیط مرطوب (لزوم استفاده از تجهیزات الکتریکی با  آی پی حفاظتی مناسب ) نیز از موارد مشاهده شده نقص ایمنی بود.&lt;/span&gt;&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5000916112206617298?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5000916112206617298/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5000916112206617298&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5000916112206617298'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5000916112206617298'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/blog-post_30.html' title='برق گرفتگی هنگام استفاده از ماشین لباسشویی'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-224241634111153102</id><published>2011-12-13T13:36:00.003+03:30</published><updated>2011-12-30T16:38:18.411+03:30</updated><title type='text'>موفقیت درخشان صنعت برق در امحاء آلاینده های پایدار</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;p align="center"&gt;&lt;strong&gt;&lt;span style="font-size:100%;color:#0000ff;"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/PCBS/pcbs2.jpg" width="225" align="bottom" border="0" height="284" hspace="0" /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt; &lt;p&gt;&lt;strong&gt;&lt;span style="font-size:100%;color:#0000ff;"&gt;در مدیریت و امحاء زیست محیطی روغن آسکارل ( PCBs )&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;  &lt;p&gt;&lt;span style="font-size:100%;"&gt;پس از سال ها تلاش و مطالعه در زمینه مدیریت و امحاء  زیست محیطی روغن آسکارل ( PCBs ) در حوزه صنعت برق کشور ، جمهوری اسلامی  ایران در ردیف کشورهای توانمند در اجرای مفاد کنوانسیون های بین المللی  آلاینده های پایدار قرار گرفت.&lt;/span&gt;&lt;/p&gt; &lt;p align="center"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/PCBS/pcb-labels.png" width="271" align="bottom" border="0" height="278" hspace="0" /&gt;&lt;/p&gt; &lt;div style="text-align: center;"&gt;&lt;span style="font-size:100%;"&gt;&lt;u&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/u&gt;&lt;/span&gt;&lt;span style="font-size:100%;"&gt;&lt;u&gt;&lt;strong&gt;&lt;a href="http://electricalsafety.blogfa.com/post-562.aspx"&gt;لینک مشاهده کامل خبر &lt;/a&gt;&lt;/strong&gt;&lt;/u&gt;&lt;/span&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-224241634111153102?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/224241634111153102/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=224241634111153102&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/224241634111153102'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/224241634111153102'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/blog-post_1814.html' title='موفقیت درخشان صنعت برق در امحاء آلاینده های پایدار'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1651577597660597539</id><published>2011-12-13T13:34:00.000+03:30</published><updated>2011-12-13T13:35:35.656+03:30</updated><title type='text'>لوزی درجات خطر مواد یا NFPA Chemical Hazard Labels</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;p align="baseline"&gt; &lt;strong style="color: rgb(255, 0, 0);"&gt;&lt;span style="font-size:85%;"&gt;لوزی درجات خطر مواد&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p style="text-align: right;"&gt;&lt;span style="font-size:85%;"&gt;جهت  پیش بینی خطرات مواد و نحوه برخورد هنگام خطر ، شامل حریق و مخاطرات  شیمیایی و حتی بهداشتی ، کدهای بین المللی پیش بینی شده است که باید علامت  های مربوطه بر روی ظروف و بسته بندی های مواد درج گردد. کلیه کدها در یک  لوزی که به چهاربخش تقسیم شده است و به آن لوزی خطر گفته می شود درج می  گردد.&lt;/span&gt;&lt;/p&gt;&lt;p style="text-align: right;"&gt;&lt;span style="font-size:85%;"&gt;نمونه این لوزی در شکل زیر آمده است :&lt;/span&gt;&lt;/p&gt;&lt;p style="text-align: right;"&gt;&lt;br /&gt;&lt;/p&gt;&lt;p style="text-align: center;"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Chemical%20Hazard%20Labels/Chemicalhazard2.jpg" /&gt;&lt;/p&gt;&lt;p style="text-align: center;"&gt;&lt;br /&gt;&lt;/p&gt;&lt;p style="text-align: right; color: rgb(255, 0, 0);"&gt;&lt;span style="font-size:85%;"&gt;&lt;strong&gt;مشخصات جدول :&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style="text-align: center;"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Chemical%20Hazard%20Labels/Chemicalhazard1.jpg" /&gt;&lt;/p&gt;&lt;p style="text-align: left;"&gt;&lt;br /&gt;&lt;/p&gt;&lt;p style="text-align: right; color: rgb(255, 0, 0);" align="baseline"&gt;&lt;strong&gt;&lt;span style="font-size:85%;"&gt;مثال :&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p style="text-align: center;"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Chemical%20Hazard%20Labels/Chemical%20Hazard%20Labels.jpg" /&gt;&lt;/p&gt;&lt;p&gt;  &lt;/p&gt; &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1651577597660597539?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1651577597660597539/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1651577597660597539&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1651577597660597539'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1651577597660597539'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/nfpa-chemical-hazard-labels.html' title='لوزی درجات خطر مواد یا NFPA Chemical Hazard Labels'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4709245422406876835</id><published>2011-12-13T13:33:00.000+03:30</published><updated>2011-12-13T13:34:09.114+03:30</updated><title type='text'>Product Safety Labels Compliant with ISO 3864-2002</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;div style="text-align: left; direction: ltr;"&gt;&lt;span style="font-size:100%;"&gt;&lt;p style="text-align: left;"&gt;ISO recommends that in order  to increase the understanding of the safety labels and its components,  product manufacturers should incorporate hazardous warnings into their  collateral materials such as: operator manuals, safety manuals,  maintenance manuals.&lt;/p&gt;&lt;strong&gt; &lt;p&gt;HAZARD SEVERITY PANELS (Signal Words):&lt;/p&gt;&lt;/strong&gt; &lt;p&gt;For products there are 3 hazard severity panels which are denoted by  the signal words: DANGER, WARNING &amp;amp; CAUTION. The 3 signal words are  reserved for personal injury hazards. Choice of the signal word is based  upon an estimate of the likelihood of exposure to the hazard and of the  probable consequences of exposure to the hazard.&lt;/p&gt;&lt;em&gt; &lt;p&gt;DANGER: Indicates an imminently hazardous situation which, if not  avoided, will result in death or serious injury. Safety Signs identified  by the signal word DANGER should be used sparingly and only for those  situations presenting the most serious hazards&lt;/p&gt; &lt;/em&gt; &lt;p style="text-align: center;"&gt;&lt;a style="display: inline;" href="http://brimar.typepad.com/.a/6a01156eb7a65c970c01156fcf495c970b-pi"&gt;&lt;img title="DangerYellow" src="http://electricalsafety.persiangig.com/image/Chemical%20Hazard%20Labels/safety%20labels2.png" class="at-xid-6a01156eb7a65c970c01156fcf495c970b " alt="DangerYellow" border="0" vspace="0" hspace="0" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;em&gt; &lt;p&gt;WARNING: Indicates a potentially hazardous situation which, if not  avoided, will result in death or serious injury. Hazards identified by  the signal word WARNING present a lesser degree of risk of injury or  death than those identified by the signal word DANGER.&lt;/p&gt;&lt;/em&gt;  &lt;/span&gt; &lt;p style="text-align: center;"&gt;&lt;span style="font-size:100%;"&gt;&lt;a style="display: inline;" href="http://brimar.typepad.com/.a/6a01156eb7a65c970c01156ed745bb970c-pi"&gt;&lt;img title="WarningYellow" src="http://electricalsafety.persiangig.com/image/Chemical%20Hazard%20Labels/safety%20labels3.png" class="at-xid-6a01156eb7a65c970c01156ed745bb970c " alt="WarningYellow" border="0" vspace="0" hspace="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-size:100%;"&gt;&lt;em&gt; &lt;/em&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:100%;"&gt;&lt;em&gt;CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;  &lt;p style="text-align: center;"&gt;&lt;a style="display: inline;" href="http://brimar.typepad.com/.a/6a01156eb7a65c970c01156fcf4cb5970b-pi"&gt;&lt;img title="CautionYellow" src="http://electricalsafety.persiangig.com/image/Chemical%20Hazard%20Labels/safety%20labels1.png" class="at-xid-6a01156eb7a65c970c01156fcf4cb5970b " alt="CautionYellow" border="0" vspace="0" hspace="0" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4709245422406876835?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4709245422406876835/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4709245422406876835&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4709245422406876835'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4709245422406876835'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/product-safety-labels-compliant-with.html' title='Product Safety Labels Compliant with ISO 3864-2002'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6314082341149591053</id><published>2011-12-13T13:30:00.000+03:30</published><updated>2011-12-13T13:31:45.541+03:30</updated><title type='text'>عدم توجه به هشدارهاي ايمني در هنگام عزاداري سالار شهيدان حادثه آفرید</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;شنبه نوزدهم آذر 1390  &lt;p&gt;&lt;strong&gt;&lt;span style="color:#0000ff;"&gt;عدم رعايت موارد ايمني و توجه ناکافي به هشدارهاي ارائه شده در جرايد و رسانه ها باز هم حادثه آفريد. &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt; &lt;p&gt;رئيس گروه ايمني شرکت توزيع نيروي برق خراسان شمالي گفت:علیرغم اطلاع  رسانی در خصوص رعايت موارد ايمني و صرفه جويي انرژي در زمان عزاداري سالار  شهيدان ، پنجشنبه شب گذشته يک مورد برق گرفتگي در يکي از کاروانهاي عزاداري  شهرستان شيروان به وقوع پیوست .&lt;br /&gt;جواد حسینی در توضيح اين مطلب اظهار  داشت: جواني 19 ساله به هنگام از تير ميدان عشايري شيروان براي گشودن پرچم  هاي عزاداري متاسفانه از چند ناحيه دچار برق گرفتگي شد و براي مداوا به  بيمارستان اين شهرستان انتقال يافت.&lt;br /&gt;وي با بيان اینکه به دليل شدت  جراحات وارده از ناحيه دست و پا و همچنين آرک زدگي صورت، مصدوم براي تکميل  مراحل مداوا به مشهد مقدس منتقل شد گفت: متاسفانه تا اين لحظه آثار چنداني  از بهبودي در وي مشاهده نشده است.&lt;br /&gt;اين مسئول با بيان اين موضوع که  تيرهاي برق، به خصوص در حوالي ترانس ها محلي مناسب براي نصب پرچم و اعلاميه  نيست اظهار داشت: هرگونه صعود غيرمجاز از تيرهاي شبکه هاي برق مي تواند  حادثه آفرين باشد. بنابراين شهروندان دقت بيشتري را در اين رابطه مبذول  دارند.&lt;/p&gt; &lt;p&gt;&lt;span style="font-size:78%;"&gt;برگرفته از سایت نسیم&lt;/span&gt;&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6314082341149591053?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6314082341149591053/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6314082341149591053&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6314082341149591053'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6314082341149591053'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/blog-post_6276.html' title='عدم توجه به هشدارهاي ايمني در هنگام عزاداري سالار شهيدان حادثه آفرید'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2625134604279133974</id><published>2011-12-13T13:28:00.000+03:30</published><updated>2011-12-13T13:30:14.321+03:30</updated><title type='text'>رضا دیگر نمی‌خندند، یاری‌اش کنیم</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;p style="TEXT-ALIGN: center"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Accident/Electrocution20/01.jpg" width="409" height="383" /&gt;&lt;/p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;رضا  39 سال سن دارد. دو سال قبل بر اثر سانحه برق گرفتگی (فشار قوی ) به  مصیبتی گرفتار آمد كه در عكس می بینید ... همه چیز از آخرین روز از اولین  ماه سال 88 شروع شد، رضا کیکاج نژاد، کارگر شرکت سامان محیط که کار تولید  آسفالت و اجرای رویه جاده‌ها را به کارفرمایی سینا گلزاری برعهده داشت.  هنگامی که در حال تخلیه آسفالت‌ها در محل مورد نظر بود ، اتاقک کامیون به  خطوط هوايي برق فشار قوی کنار جاده ( سیم‌های برق 33 هزار ولت )  برخورد  می‌کند، لرزشی سخت او را در بر می‌گیرد و بر اثر شدت فشار برق گرفتگی به  میان جاده پرتاب می‌شود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;p align="center"&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;&lt;img style="WIDTH: 401px; HEIGHT: 498px" src="http://electricalsafety.persiangig.com/image/Accident/Electrocution20/02.jpg" width="401" height="534" /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;چشمانش  را در بیمارستان اندیمشک باز می‌کند، آنجا ماندگار نمی‌شود و به بیمارستان  طالقانی اهواز منتقلش می‌کنند و بعد از سه روز او را با پزشک و پرستار و  با هواپیما به بیمارستان سوانح سوختگی امام موسی کاظم(ع) اصفهان منتقل  می‌شود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;رضا  کیکاج نژاد بارها و بارها در بیمارستان تحت عمل‌های مختلف جراحی قرار  گرفت، در این اعمال جراحی که برای قطع اندام‌ها و ترمیم حفره‌های عمیقی که  درست به شکل قرینه در زیر بغل‌ها، پهلوها، زیر زانوها و سمت کلیه‌ها او  ایجاد شده بود حداقل ده بار بیهوشی عمومی را تجربه کرد و بعد از آن نیز  برای شتسشو و کنترل عفونت اندام‌های تحتانی یک بیهوشی دیگر را نیز تجربه  کرد، ساعد دستان راست و چپش و پای راست و چپ او قطع شد تا او زنده بماند. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center"&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;&lt;span style="FONT-FAMILY: Tahoma"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Accident/Electrocution20/03.jpg" align="bottom" border="0" width="351" height="263" hspace="0" /&gt;&lt;/span&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;در این دو سال چه بر خانواده رضا رفت ؟... وقتی كه 11 عمل جراحی را شاهد بودند ... بخدا سوختند. همه شان سوختند ... مثل رضا&lt;br /&gt;پدرش  كه كارگر بازنشسته راه آهن است تنها مایملك اش از این دنیا كه در یك خانه  دو اطاقه خلاصه شده بود را فروخت و خرج فرزندش كرد و خودش به مصیبتی باور  نكردنی به اجاره نشینی در دورترین نقطه شهر رفت. پیرمرد، حالا مجبور است در  خیابان های شاهین شهر و با اتومبیلی كه همشهریان از سر دلسوزی در اختیارش  می گذارند بدنبال مسافر بدود بلكه از پس مخارج درمان دردهای فرزندش كه زیر  گوشش ناله های جگرخراش می كند برآید ... اما نمی آید.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="FONT-FAMILY: Tahoma"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Accident/Electrocution20/04.jpg" align="bottom" border="0" width="364" height="273" hspace="0" /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;كلیه  های (رضا) دارد عفونت می كند. عروق اش تاب گردش خون از دست می دهند.  استخوانهایش مرتب رشد می كنند و از زیر پوست بیرون می زنند ...&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#000066;"&gt;دانشكده  توانبخشی تهران برای پروتز دست و پای رضا فاكتور صد میلیونی صادر كرده و  مدیر بهزیستی قول داده اگر مسئولان بالاتر قبول كنند 2 میلیون تومان به او  كمك نماید.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#006600;"&gt;دوستان عزیزی که مایل به کمک هستند میتوانند &lt;span lang="fa"&gt;کمک های نقدی خود را &lt;/span&gt;به شماره کارت 5894631203295555 بانک رفاه به نام رضا کیکاج نژاد &lt;span lang="fa"&gt;واریز&lt;/span&gt; کنند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="color:#006600;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center; COLOR: rgb(255,0,0)"&gt;&lt;strong&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-size:-0;"&gt;دوستانی که قصد کمک دارند بهتر است قبل از &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center; COLOR: rgb(255,0,0)"&gt;&lt;strong&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-size:-0;"&gt;هر اقدامی ابتدا با بهزیستی تماس گرفته و&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center; COLOR: rgb(255,0,0)"&gt;&lt;strong&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-size:-0;"&gt;از صحت این خبر و معلولیت شخص&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center; COLOR: rgb(255,0,0)"&gt;&lt;strong&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-size:-0;"&gt;آقای رضا کیکاچ نژاد و راه های &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center; COLOR: rgb(255,0,0)"&gt;&lt;span style="font-family:Tahoma;font-size:100%;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-family:Tahoma;"&gt;&lt;span style="font-size:-0;"&gt;&lt;strong&gt;تماس مستقیم با ایشان اطمینان حاصل نمایند.&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2625134604279133974?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2625134604279133974/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2625134604279133974&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2625134604279133974'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2625134604279133974'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/blog-post_13.html' title='رضا دیگر نمی‌خندند، یاری‌اش کنیم'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1752811674102581787</id><published>2011-12-13T13:27:00.000+03:30</published><updated>2011-12-13T13:28:50.809+03:30</updated><title type='text'>حریق در فروشگاه مواد غذایی به دلیل بروز اتصالی در سیم های برق</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;span id="dnn_ctr437_ContentPane" class="DNNAlignright"&gt;&lt;span class="Normal"&gt;&lt;span style="font-size:85%;"&gt;21 آذرماه 1390&lt;/span&gt;&lt;strong&gt;&lt;span style="font-size:85%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;  &lt;p&gt;&lt;span id="dnn_ctr437_ContentPane" class="DNNAlignright"&gt;&lt;span class="Normal"&gt;&lt;strong&gt;&lt;span style="font-size:85%;"&gt;بروز اتصالی در سیم های برق فروشگاه مواد غذایی عامل آتش سوزی و برجای ماندن خسارت مالی شد.&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p style="TEXT-ALIGN: center"&gt;&lt;span id="dnn_ctr437_ContentPane" class="DNNAlignright"&gt;&lt;span class="Normal"&gt;&lt;span style="font-size:85%;"&gt;&lt;img src="http://www.125.ir/Portals/0/Image/1390/atashsoozi/forooshgah/forooshgah%20%2811%29.JPG" align="bottom" border="0" hspace="0" /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;span id="dnn_ctr437_ContentPane" class="DNNAlignright"&gt;&lt;span class="Normal"&gt;&lt;span style="font-size:85%;"&gt;به  گزارش خبرنگار پایگاه خبری 125 ستاد فرماندهی آتش نشانی تهران ساعت 19:30  دقیقه شامگاه دیروز با دریافت خبر رخداد این آتش سوزی بلافاصله آتش نشانان  ایستگاه 69 را به محل حادثه در دهکده المپیک، خیابان ورزش شرقی اعزام كرد.&lt;br /&gt;به  گفته منوچهر رهی فرمانده آتش نشانان، دود بسیار زیادی از این فروشگاه  بیرون می آمد و آتش نشانان بی درنگ پس از ایمن سازی محل و قطع کردن جریان  برق فروشگاه با بکارگیری تجهیزات خاموش کننده شعله های آتش که بالکن  فروشگاه را در بر گرفته بود مهار و با خاموش کردن کامل آتش سوزی از افزایش  خسارت مالی جلوگیری کردند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1752811674102581787?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1752811674102581787/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1752811674102581787&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1752811674102581787'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1752811674102581787'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/blog-post.html' title='حریق در فروشگاه مواد غذایی به دلیل بروز اتصالی در سیم های برق'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4878077214688499714</id><published>2011-12-13T13:25:00.000+03:30</published><updated>2011-12-13T13:27:35.600+03:30</updated><title type='text'>Scafftag چیست و به چه منظور استفاده می شود؟</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;p style="text-align: center;"&gt;&lt;span style="font-size:130%;"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Scafftag/Scafftag1.jpg" width="393" height="135" /&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt; &lt;/span&gt;&lt;span style="font-family: Tahoma;"&gt;scafftag&lt;/span&gt;&lt;span style="font-family: 'B Nazanin';"&gt; &lt;span&gt; در  واقع یک کارت پلاستکی است به رنگ های قرمز، زرد و سبز که بمنظور تامین  امنیت پرسنل جهت کار بر روی دار بست از آن استفاده می گردد. &lt;/span&gt;&lt;/span&gt;&lt;span style="font-family: 'B Nazanin';"&gt; زمانیکه برروی داربست هیچگونه کارتی زده نشده باشد بمعنی قرمز بوده و استفاده از آن ممنوع است. &lt;/span&gt;&lt;span style="font-family: 'B Nazanin';"&gt; این  کارت بایستی در مسیر های ورودی داربست یعنی جلو نردبان و پله نصب می گردد  تا پرسنل براحتی بتوانند آنرا رویت نموده وبرابر مقررات این کارت عمل  نمایند.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style="text-align: center;"&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Scafftag/Scafftag8.jpg" align="bottom" border="0" vspace="0" width="387" height="234" hspace="0" /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir="rtl"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;span style="color: red;"&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir="rtl"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;span style="color: red;"&gt;&lt;strong&gt;کارت قرمز&lt;/strong&gt;&lt;/span&gt;: بمعنی ساخت و پایان کار داربست بوده و استفاده از داربست ممنوع می باشد. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir="rtl" style="text-align: center;"&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="color: rgb(255, 204, 0); font-family: 'B Nazanin';"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Scafftag/Scafftag7.jpg" align="bottom" border="0" vspace="0" hspace="0" /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir="rtl"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="color: rgb(255, 204, 0); font-family: 'B Nazanin';"&gt;&lt;strong&gt;کارت زرد&lt;/strong&gt;&lt;/span&gt;&lt;span style="font-family: 'B Nazanin';"&gt;:  بمعنی پایان انجام بازدید از داربست می باشد و مشخصات داربست از قبیل  ظرفیت و تاریخ ساخت داربست بانضمام موقعیت شغلی و امضا بازدید کننده برروی  آن دیده می شود.  &lt;/span&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir="rtl" style="text-align: center;"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;span style="color: rgb(51, 153, 102);"&gt;&lt;strong&gt;&lt;span style="font-family: verdana,tahoma,arial,helvetica,sans-serif;"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Scafftag/scafftag.jpg" align="bottom" border="0" vspace="0" hspace="0" /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir="rtl"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;span style="color: rgb(51, 153, 102);"&gt;&lt;strong&gt;کارت سبز&lt;/strong&gt;&lt;/span&gt;:  بمعنی داربست آماده و تائید شده پس از بازدید جهت استفاده آزاد از دار بست  است که بعد از کارت زرد زده می شود که برروی آن کلیه اطلاعات دار بست  به انضمام مشخصات فرد بازدید کننده داربست دیده میشود . &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style="text-align: center;" dir="rtl"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Scafftag/Scafftag2.PNG" /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style="text-align: center;" dir="rtl"&gt;&lt;br /&gt;&lt;/p&gt;&lt;p style="text-align: center;" dir="rtl"&gt;&lt;img src="http://electricalsafety.persiangig.com/image/Scafftag/Scafftag10.jpg" width="343" height="227" /&gt;&lt;/p&gt;&lt;p dir="rtl"&gt;&lt;span style="font-family:verdana,tahoma,arial,helvetica,sans-serif;font-size:130%;"&gt;&lt;span style="font-family: 'B Nazanin';"&gt; &lt;/span&gt;&lt;span style="color: red; font-family: 'B Nazanin';"&gt; &lt;strong&gt;توجه: فقط یک داربست بند کاردان می تواند کارت را از روی داربست برداشته ویا آن را تعویض نماید. &lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;span style="color: red; font-family: 'B Nazanin';"&gt; فقط درصورت نصب شدن کارت سبز آن داربست قابل استفاده می باشد.   &lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4878077214688499714?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4878077214688499714/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4878077214688499714&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4878077214688499714'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4878077214688499714'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/scafftag.html' title='Scafftag چیست و به چه منظور استفاده می شود؟'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7753297289140190108</id><published>2011-12-13T13:23:00.000+03:30</published><updated>2011-12-13T13:25:02.027+03:30</updated><title type='text'>بازی زندگی در کارگاه‎های ساختمانی!/ 778 نفر در 6 ماه کشته شدند</title><content type='html'>&lt;div dir="rtl" style="text-align: right;"&gt;&lt;p dir="rtl"&gt;20 آذر 1390&lt;/p&gt; &lt;div&gt; &lt;table&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;خبرگزاری مهر-گروه اقتصادی: مرگ هر نفر در  محیط کار حدود 7 هزار روز کاری را از بین می‎برد، با این حال بی‌توجهی به  آموزش و آماده‎سازی نیروی کار برای مقابله با حوادث ناشی از کار، باعث  تکرار حوادث تلخ مرگ و میر کارگران می‌شود.&lt;/span&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt; &lt;tr&gt; &lt;td&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;به گزارش خبرنگار مهر، در 6 ماهه نخست امسال  778 نفر در حوادث ناشی از کار جان خود را از دست داده اند که در مقایسه با  سال گذشته 18.8درصد افزایش یافته است. تعداد جان باختگان 6 ماهه حوادث ناشی  از کار سال گذشته، 655 نفر بوده است.&lt;/span&gt;&lt;/p&gt; &lt;p dir="rtl" align="center"&gt;&lt;img alt="" src="http://electricalsafety.persiangig.com/image/SAFETY/535035_orig.jpg" align="bottom" border="0" width="420" height="278" hspace="0" /&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;از کل افراد فوت‌ شده در حوادث ناشی از کار نیمه او&lt;/span&gt;&lt;span style="font-size:85%;"&gt;ل  امسال 770 نفر مرد و مابقی نیز زن هستند و استانهای تهران و اصفهان به  ترتیب با 107 و 101نفر فوتی در رتبه‌های اول و دوم مرگ و میر ناشی از حوادث  کار قرار دارند.&lt;/span&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;&lt;strong&gt;مرگ 1290 نفر در 89&lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;همچنین تعداد کل فوت‌ شدگان حوادث ناشی از کار  سال گذشته در کشور هزار و 290 نفر بوده است که هزار و 271 نفر از این  تعداد مرد و 19 نفر نیز زن بودند.&lt;/span&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;این آمار جدیدترین گزارش سازمان پزشکی قانونی  کشور است که به تازگی منتشر شده و بر این مهم تاکید دارد که لازم است تا به  صورت جدی به مقوله آموزش در محیط های کاری و بنگاه ها و به ویژه بخش های  خطرزا مانند کارهای ساختمانی پرداخته شود.&lt;/span&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;span style="font-size:85%;"&gt;همچنین موید این مطلب است که ضرورت دارد تا  بنگاه ها بخشی از هزینه های مربوط به آموزش نیروی انسانی خود را به امر  "اول ایمنی، بعد کار" اختصاص دهند چرا که هرچه توجه نیروی کار شاغل در  بنگاه ها به مقوله های ایمنی و اقدامات احتیاطی در محیط کار جلب شود، از  آنسو شاهد نزول آمار مرگ و میر افراد در حین کار خواهیم بود.&lt;/span&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/div&gt; &lt;p dir="rtl"&gt;&lt;strong&gt;آموزش ایمنی؛ هزینه اضافی&lt;/strong&gt;&lt;strong&gt;!&lt;/strong&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;با اینکه موضوع ایمنی و جلوگیری از حوادث ناشی از کار در  بنگاه ها و محیط های کاری بسیار حائز اهمیت است اما باید به این حقیقت تلخ  هم اشاره کرد که امروز بسیاری از واحدها به ویژه آنهایی که با لحاظ ماهیت  بیشتر در معرض خطرات ناشی از کار هستند، هزینه آموزش و ارتقاء سطح ایمنی در  کار را صرفا یک هزینه سربار و اضافه می پندارند و توجه چندانی به آن  ندارند.&lt;/p&gt; &lt;p dir="rtl"&gt;البته در سالهای گذشته در پاره ای از موارد مطرح شد که لازم  است تا در بنگاه ها واحدهایی برای پیگیری امور ایمنی و بهداشت کار ایجاد  شود اما آنچنان که باید در این راه گام برداشته نشد و نشانه آن هم اینکه هر  چند وقت یکبار شاهد انتشار آمارهای جدید حوادث ناشی از کار و در بدترین  حالت آن مرگ و میر افراد هستیم.&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;strong&gt;35درصد کل مرگ و میر در ساختمان&lt;/strong&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;ساختمان و کارگاه های مربوط به آن به عنوان یکی از مهم ترین  بخش هایی که نیازمند جدی ترین آموزش ها و رعایت نکات ایمنی در کار است  بالاترین آمار حوادث ناشی از کار را در اختیار دارند و با رکورد 35 درصد از  کل حوادث پیشتاز است.&lt;/p&gt; &lt;p dir="rtl"&gt;با این حال هنوز هم هزاران کارگاه ساختمان سازی در کوچه ها و  خیابان ها هستند که بدون رعایت کوچکترین ایمنی و اقدامات پیشگیرانه مشغول  به کار هستند.&lt;/p&gt; &lt;p dir="rtl"&gt;از سویی با عدم آموزش و آشنایی نیروی کار شاغل در این بخش به  نکات ایمنی و مهارت در اشتغال به کار در بخش های مختلف ساختمانی و همچنین  عدم استفاده از پوشش های حمایتی مانند بیمه، ساختمان رکوردار مرگ و میر و  حوادث ناشی از کار در کشور است.&lt;/p&gt; &lt;p dir="rtl"&gt;محمد اصابتی در گفتگو با مهر با بیان اینکه به منظور نظارت بر  حسن اجرای قانون در 8 ماهه ابتدای امسال 180هزار بازرسی ادواری از واحدهای  مشمول قانون کار انجام شد، گفت: این میزان نسبت به مدت مشابه سال قبل  12درصد رشد یافته است.&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;strong&gt;تدوین آئین نامه‌های پیشگیرانه&lt;/strong&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;مدیرکل بازرسی کار وزارت تعاون، کار و رفاه اجتماعی از تلاش  برای تهیه آئین نامه ها و دستورالعمل های مربوط به تقویت ایمنی و بهداشت  کار خبر داد و اظهار داشت: از 52 آئین نامه تهیه شده از سال 38 تاکنون،  16مورد مربوط به دولت دهم است.&lt;/p&gt; &lt;p dir="rtl"&gt;اصابتی ادامه داد: البته با توجه به خطرپذیری، گستردگی و تنوع  کار در بخش ساختمان که به صورت متوسط بیش از 35 درصد حوادث ناشی از کار را  به خود اختصاص می دهد، 2 آئین نامه ایمنی بخش ساختمان در شورای عالی حفاظت  فنی در این زمینه تصویب شد.&lt;/p&gt; &lt;p dir="rtl"&gt;وی از تلاش بخش بازرسی وزارت تعاون، کار و رفاه اجتماعی برای  عقد تفاهم‌نامه با شهرداری‌ها به منظور ارتقای سطح ایمنی در کارگاه های  ساختمانی بزرگ خبر داد و گفت: در این راستا برای استقرار مسئول ایمنی مقیم  در کارگاه های ساختمانی بزرگ در تلاش برای مذاکره و عقد تفاهم نامه با  شهرداری ها هستیم.&lt;/p&gt; &lt;p dir="rtl"&gt;&lt;strong&gt;مرگ 2.3میلیون نفر در جهان&lt;/strong&gt;&lt;/p&gt; &lt;p dir="rtl"&gt;این مقام مسئول در وزارت تعاون، کار و رفاه افزود: طبق اعلام  سازمان بین المللی کار در سال 2008، 2 میلیون و 340 هزار نفر در جهان بر  اثر حوادث ناشی از کار جان خود را از دست دادند که 75درصد از آنان به خاطر  بروز بیماری ها و آلایندگی در محیط کار بوده است.&lt;/p&gt; &lt;p dir="rtl"&gt;اصابتی با اشاره به اینکه حوادث ناشی از کار حداقل 4 درصد از  تولید ناخالص هر کشور را به خود اختصاص می دهد، افزود: هر حادثه منجر به  فوت در محیط‌های کاری بین 6 تا 7 هزار روز کاری را از بین می‌برد.&lt;/p&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7753297289140190108?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7753297289140190108/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7753297289140190108&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7753297289140190108'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7753297289140190108'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/12/778-6.html' title='بازی زندگی در کارگاه‎های ساختمانی!/ 778 نفر در 6 ماه کشته شدند'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7947777816426615490</id><published>2011-11-05T23:50:00.000+03:30</published><updated>2011-11-05T23:53:02.440+03:30</updated><title type='text'>Why Understanding Annex F and FMECA Is Important</title><content type='html'>&lt;div dir="rtl" align="left"&gt;&lt;/div&gt;&lt;br /&gt;&lt;p dir="ltr" align="left"&gt;In accordance with NFPA 70E® Section 110.3(F), an electrical safety program should include a hazard identification and risk assessment procedure. This procedure is to be used before work is started within the limited approach boundary or within the arc flash boundary under certain conditions. The conditions are that there are energized electrical conductors and circuit parts operating at 50 volts or more, or that an electrical hazard exists. From the pertinent definition of exposed and of limited approach boundary in Article 100, there is no limited approach boundary if the energized conductors or circuit parts operating at 50 volts or more are suitably guarded, isolated or insulated. The determination of the arc flash boundary is independent of the determination of the shock hazard boundaries. Finally, the electrical safety plan is to identify the process by which an employee can identify hazards and assess risks before work is started, including potential risk mitigation strategies.&lt;br /&gt;&lt;br /&gt;Informational Note 2 to 110.3(F) refers to Informative Annex F, Hazard Analysis, Risk Estimation, and Risk Evaluation Procedure. Informative Annex F provides guidance on a qualitative approach to risk assessment – including risk estimation and risk evaluation. This procedure can be seen as being related to the failure mode, effects, and criticality analysis (FMECA) method, which was developed by the U.S. military, described in 1949 in the U.S. Armed Forces Military Procedures document MIL-P-1629[1],and revised in 1980 as MIL-STD-1629A[2]. Having a basic understanding of some of the terms used in FMECA may be helpful in understanding Informative Annex F and the procedures and processes described in that annex. Hazard identification can be seen as a form of failure mode identification, determining the severity of the harm can be seen as a form of effects analysis, and risk determination can be seen as a form of criticality analysis. Following are some terms from FMECA that have been modified or adapted for electrical safety:&lt;br /&gt;&lt;br /&gt;Failure (Electrical Safety). For our purposes, a failure is the loss of an intended safety function of the electrical system equipment or components or a failure in the electrical safety procedures or a human error that, under stated conditions, resulted in an electrical safety incident or near miss of an electrical safety incident.&lt;br /&gt;&lt;br /&gt;Failure Mode (Electrical Safety). Failure mode is the manner by which the electrical safety failure occurred. (It generally describes the way the safety failure occurred.)&lt;br /&gt;&lt;br /&gt;Failure Effect (Electrical Safety). Failure effect is the immediate consequences of an electrical safety failure. It is the result of an electrical safety failure mode on the function of the electrical safety system as perceived by the user.&lt;br /&gt;&lt;br /&gt;Failure Cause. The defect or defects which are the underlying cause of the electrical safety failure or which started a process that led to the electrical safety failure.&lt;br /&gt;&lt;br /&gt;Severity. Severity is the consequences of a failure mode. Severity considers the worst potential consequences of a failure, determined by the degree of injury, property damage, or system damage that can ultimately occur. For purposes of electrical safety, we are mainly concerned with the degree of injury.&lt;br /&gt;&lt;br /&gt;The qualitative determination of risk under the procedures and process described in Informative Annex F uses ordinal numbers, just as under FMECA as modified by the automobile industry[3]. Since ordinal numbers are used to determine risk, the effect or limitations of the use of ordinal numbers in determining risk should be understood. See the related article on necplus, Some Limitations of Using a Qualitative Method to Determine Risk (Risk Priority Number or Risk Priority Ranking), for more information on this subject. Under FMECA as modified by the automotive industry[3] risk is prioritized based on the Risk Priority Number (RPN) determined, which takes into consideration how serious the consequences are, how frequently they occur, and how easily they can be detected. The RPN evaluation approach may be seen as a qualitative method of criticality analysis or as an alternative evaluation approach to criticality analysis. The use of risk priority number evaluation under FMECA as modified by the automotive industry[3] is determined by the following equation:&lt;br /&gt;&lt;br /&gt;RPN = SN x ON x DN&lt;br /&gt;&lt;br /&gt;Where:&lt;br /&gt;&lt;br /&gt;SN = Severity number&lt;br /&gt;&lt;br /&gt;ON = Occurrence number&lt;br /&gt;&lt;br /&gt;DN = Detection number&lt;br /&gt;&lt;br /&gt;The RPN technique can be tailored to other types of applications. Under the procedures and processes of Informative Annex F, risk can be determined using the following equation:&lt;br /&gt;&lt;br /&gt;Risk = Se x Po&lt;br /&gt;&lt;br /&gt;Where:&lt;br /&gt;&lt;br /&gt;Risk = Risk related to identified hazard/task pair&lt;br /&gt;&lt;br /&gt;Se = Severity of the possible harm&lt;br /&gt;&lt;br /&gt;Po = Probability of occurrence of that harm&lt;br /&gt;&lt;br /&gt;The similarity between FMECA and this RPN technique can be seen by comparing the above equations. The difference is that in RPN, a DN is not considered. The determination of risk under Informative Annex F can be seen as a modification of the RPN technique or criticality analysis.&lt;br /&gt;&lt;br /&gt;The purpose of determining risk is the same as the purpose of determining a RPN: to determine a ranking order for taking corrective action. A failure mode and effects analysis documents the current state of knowledge and actions taken regarding the risk of failures.&lt;br /&gt;&lt;br /&gt;The results of FMECA and hazard identification and risk assessment should be the same to develop actions to prevent or reduce the severity or likelihood of failures, starting with the highest-priority ones.&lt;br /&gt;&lt;br /&gt;Both RPN and FMECA may be used to evaluate risk management priorities (to mitigate known vulnerabilities), and both help select remedial actions to reduce the cumulative impacts of risks (life-cycle consequences) from a fault (system failure). Therefore, one may want to consider using the term risk priority number rather than risk. Regardless of the resulting determined risk or RPN, special attention should be given when a high severity has been determined. The related article on necplus, Risk Assessment (Risk or Risk Priority Number Assessment), will help explain how to determine a risk score or rather a risk priority number for an electrical hazard/task pair.&lt;br /&gt;&lt;br /&gt;FMECA and hazard identification and risk assessment are not intended for top-down analysis, since they might only identify the major failure modes in the electrical safety system. Other techniques are available to accomplish those goals. However, FMECA and hazard identification and risk assessment can be used as a bottom-up tool to complement and augment other methods, to identify many more causes and failure modes resulting in top-level symptoms and as a method to evaluate risk.&lt;br /&gt;&lt;br /&gt;[1] MIL-P-1629 – Procedures for performing a failure mode and effect and critical analysis. Department of Defense (US). November 9, 1949.&lt;br /&gt;&lt;br /&gt;[2] MIL-STD-1629A – Procedures for performing a failure mode and effect and criticality analysis. Department of Defense (USA). November 24, 1980.&lt;br /&gt;&lt;br /&gt;[3] SAEJ-1739 – Surface Vehicle Recommended Practice: Potential Failure Mode and Effects Analysis in Design (Design FMEA) and Potential Failure Mode and Effects Analysis in Manufacturing (Process FMEA) Reference Manual, July 1994.&lt;br /&gt;&lt;br /&gt;Michael Fontaine currently is a Senior Electrical Engineer with the NFPA. He is a Registered Professional Electrical Engineer and also has licenses in several other areas. He has over thirty five years of electrical experience including over thirty years as a Registered Professional Electrical Engineer. His experience includes engineering, designing, drafting, purchasing, testing and inspecting, writing about, developing training programs, and teaching about electrical systems and electrical safety issues. He is well versed in the requirements of NFPA 70, the National Electrical Code®, and NFPA 70E®, the Standard for Electrical Safety in the Workplace. &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7947777816426615490?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7947777816426615490/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7947777816426615490&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7947777816426615490'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7947777816426615490'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/11/why-understanding-annex-f-and-fmeca-is.html' title='Why Understanding Annex F and FMECA Is Important'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6538916757775710738</id><published>2011-11-05T23:47:00.001+03:30</published><updated>2011-11-05T23:50:16.808+03:30</updated><title type='text'>برق کولر دانشگاه جان دانشجویی را گرفت</title><content type='html'>۱۲ آبان ۱۳۹۰&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;رئیس دانشکده پرستاری و مامایی ایرانشهر گفت: یکی از دانشجویان ساکن در خوابگاهی در ایرانشهر بر اثر برق گرفتگی توسط کولر آبی جان باخت. &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;br /&gt;&lt;div align="right"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 267px; DISPLAY: block; HEIGHT: 266px; CURSOR: hand" border="0" alt="" src="http://damatajhiz.com/media/images/products/p-259(0).jpg" /&gt;&lt;/strong&gt;محمدعلی رضایی اظهار داشت: محمد جفاله دانشجوی 22 ساله ترم سه رشته پرستاری در این دانشکده بود که شب هنگام بر اثر برق گرفتگی توسط کولر آبی درگذشت. وی گفت: تمام وسائل برقی خوابگاه همزمان با شروع سال تحصیلی کنترل و از صحت عملکرد آنها اطمینان حاصل شده است و بروز هرگونه مشکل در عملکرد این دستگاه ها قبل از موعد کنترل بعدی باید توسط دانشجویان ساکن در خوابگاه به سرپرستی گزارش شود. وی افزود: بی احتیاطی دانشجو در تماس با وسیله برقی به هنگام روشن بودن، موجب بروز این حادثه شده است.&lt;br /&gt;عزیزالله امیریان رئیس بیمارستان خاتم الانبیاء (ع) ایرانشهر نیز در این زمینه بیان داشت: مرحوم محمد جفاله پس از انتقال توسط مرکز مدیریت حوادث و فوریت های پزشکی به این بیمارستان، به مدت 45 دقیقه مورد احیاء قلبی ریوی قرار گرفت که متاسفانه موفقیت آمیز نبود. همچنین به گزارش اداره هواشناسی دمای هوای ایرانشهر در شب حادثه 20 درجه سانتیگراد بالای صفر بوده است.&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6538916757775710738?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6538916757775710738/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6538916757775710738&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6538916757775710738'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6538916757775710738'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/11/blog-post_05.html' title='برق کولر دانشگاه جان دانشجویی را گرفت'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4969509138201702328</id><published>2011-11-05T23:41:00.003+03:30</published><updated>2011-11-05T23:58:52.290+03:30</updated><title type='text'>دریل کاری و خطر برق گرفتگی</title><content type='html'>&lt;a href="http://electricalsafety.persiangig.com/image/Electrical%20Safety%20Pictures/man_drilling_wall_ie270-024.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 360px; DISPLAY: block; HEIGHT: 228px; CURSOR: hand" border="0" alt="" src="http://electricalsafety.persiangig.com/image/Electrical%20Safety%20Pictures/man_drilling_wall_ie270-024.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;br /&gt;&lt;div dir="rtl" align="center"&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="color:#ff0000;"&gt;توصیه ایمنی !&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;قبل از دریل کاری روی دیوارها ،&lt;br /&gt;&lt;br /&gt;از عدم وجود سیم ها و کابل های برق&lt;br /&gt;&lt;br /&gt;در زیر کار ، اطمینان حاصل نمایید.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 230px; DISPLAY: block; HEIGHT: 147px; CURSOR: hand" border="0" alt="" src="http://electricalsafety.persiangig.com/image/Electrical%20Safety%20Pictures/Safetytipunamarkedelectrical.jpg" /&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4969509138201702328?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4969509138201702328/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4969509138201702328&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4969509138201702328'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4969509138201702328'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/11/blog-post.html' title='دریل کاری و خطر برق گرفتگی'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8645459204175679954</id><published>2011-08-21T01:33:00.000+04:30</published><updated>2011-08-21T01:34:30.514+04:30</updated><title type='text'>شرایط یک اتصال زمین خوب</title><content type='html'>1- پایین بودن مقاومت اتصال زمین در حد استاندارد&lt;br /&gt;&lt;br /&gt;2- مقاوم در برابر فساد تدریجی و عوامل مخرب زمین. ( اثر مواد شیمیایی خاک بر روی هادی زمین یا خوردگی شیمیایی )&lt;br /&gt;&lt;br /&gt;3- قابلیت تحمل جریان های زیاد و تکراری&lt;br /&gt;&lt;br /&gt;4- دوام و طول عمر بیشتر&lt;br /&gt;&lt;br /&gt;5- جلوگیری از خوردگی الکتروشیمیایی ( تشکیل پیل به وسیله فلزات ناهمگون در زمین )&lt;br /&gt;&lt;br /&gt;6- مقاوم در برابر نیروهای مکانیکی که ممکن است سبب پارگی هادی زمین شوند.&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8645459204175679954?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8645459204175679954/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8645459204175679954&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8645459204175679954'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8645459204175679954'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/08/blog-post_9618.html' title='شرایط یک اتصال زمین خوب'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4470962084861719055</id><published>2011-08-21T01:31:00.000+04:30</published><updated>2011-08-21T01:33:30.639+04:30</updated><title type='text'>نکته مهم در ارتباط با اتصال زمین</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;نکته ای که در خصوص اتصال زمین ضروری است عرض کنم این است که براي تأسيسات و تجهیزات برقی نمي‌توان از لوله هاي آبرساني عمومي، لوله‌هاي گاز، نفت، هواي فشرده و فاضلاب به عنوان تنها وسيله اتصال به زمين استفاده كرد.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;بارها دیده شده به همین دلیل، لوله های آب تعداد زیادی از منازل در یک منطقه برق دار شده است و همکارانم با زحمت زیادی منزل به منزل بررسی کرده و در نهایت متوجه همین نکته شده اند که یک مصرف کننده از لوله آب به عنوان اتصال زمین استفاده کرده و نشتی جریان ناشی از مشکل عایقی وسیله برقی وارد لوله های آب شده است.&lt;br /&gt;&lt;br /&gt;توجه داشته باشید، در چنین شرایطی نه تنها این نوع اتصال زمین مؤثر نمی باشد ( باعث قطع فیوز حفاظتی نمی شود ) ، بلکه با این اقدام لوله های آب بسیاری از منازل اطراف برق دار شده و چه بسا این مسئله عامل بروز پیامدهای ناگواری در محل شود ( بدترین شرایط مربوط به افرادی است که در همان لحظه زیر دوش آب باشند ) که طبیعی است در صورت بروز حادثه ، فرد یا سازمانی که اقدام به اینکار نموده، باید به مراجع قضایی پاسخگو باشد &lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4470962084861719055?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4470962084861719055/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4470962084861719055&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4470962084861719055'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4470962084861719055'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/08/blog-post_21.html' title='نکته مهم در ارتباط با اتصال زمین'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4601736074789237285</id><published>2011-08-17T01:17:00.000+04:30</published><updated>2011-08-17T01:19:35.053+04:30</updated><title type='text'>قانون كار با هدف پايداري مشاغل اصلاح می شود</title><content type='html'>&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;معاون روابط كار وزارت تعاون ، كار و رفاه اجتماعي :&lt;br /&gt;&lt;br /&gt;قانون كار با هدف پايداري مشاغل اصلاح می شود&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;معاون روابط كار وزارت تعاون ، كار و رفاه اجتماعي رويكرد اصلاح قانون كار را ايجاد انعطاف پذيري در روابط كار با هدف پايداري مشاغل دانست .&lt;br /&gt;&lt;br /&gt;مهندس ابراهيم نظري جلالي كه در دومين جلسه شوراي عالي كار پيرامون بازنگري قانون كار سخن مي گفت ، خاطر نشان كرد : با حفظ اشتغال و پايداري توليد مي توان اصل صيانت از نيروي كار را محقق كرد .&lt;br /&gt;&lt;br /&gt;در اين جلسه كه با حضور نمايندگان كارگران و كارفرمايان تشكيل شد ، موادي از قانون كار جهت بازنگري به بحث گذاشته شد كه مهندس نظري جلالي پيشنهادات مطروحه را حاصل کار كارشناسي با مشاركت تشكل هاي كارگري و كارفرمايي از سال 85 عنوان كرد و افزود : علاوه بر نظر خواهي از جمع كثيري از تشكل ها و كارشناسان و صاحب نظران در دولت دهم ، فقط هزار فقره نظر خواهي براي بازنگري قانون كار در دولت نهم صورت گرفته است .&lt;br /&gt;&lt;br /&gt;مهندس نظري جلالي رويكرد اصلاح قانون كاررا انعطاف پذيري بيشتر در روابط كار ، رونق فضاي كسب و كار ، تشويق سرمايه گذاري ، حفظ اشتغال و مزد منعطف دانست و با اشاره به اين كه امروزه بايد امنيت شغلي را در توانمندي نيروي كار جستجو كرد افزود : با حفظ اشتغال و توليد مي توان از نيرو كار صيانت كرد .&lt;br /&gt;&lt;br /&gt;وي اصلاح و بازنگري قانون كار را الزام برنامه پنجم توسعه دانست و افزود : تجارب 20 ساله اجراي قانون و مشكلات ناشي از برخي مواد ، بازنگري در آن را ضروري ساخته است . به طوري كه هنوز برخي مواد بدليل نداشتن جنبه هاي اجرايي ، هنوز فاقد آيين نامه هستند .&lt;br /&gt;&lt;br /&gt;معاون وزير تعاون ، كار و رفاه اصلاحات پيشنهادي را حاصل جمع نظرات جامعه كارگري و كارفرمايي دانست و افزود : در اصلاح قانون به جنبه هاي اجرايي ، تامين حقوق شركاي اجتماعي و توسعه سرمايه گذاري توجه شده است .&lt;br /&gt;&lt;br /&gt;وي پاره اي از مسايل حوزه روابط كار را ناشي از مشكلات موجود در بازار كار دانست و با اشاره به محدوديت زماني در مدت فعاليت مجلس شوراي اسلامي ، خواستار اهتمام بيشتر نمايندگان جامعه كارگري و كارفرمايي به اين موضوع شد .&lt;br /&gt;&lt;br /&gt;در اين جلسه مفاد مطرح براي اصلاح به بحث و تبادل نظر گذاشته شد و نمايندگان جامعه كارگري و كارفرمايي هريك نظرات خود را مطرح كرد .&lt;br /&gt;&lt;br /&gt;نمايندگان كارگران ، تامين نظر شركاي اجتماعي و توجه به اصل امنيت شغلي را از مولفه هاي مهم در اصلاح قانون كار دانستند و افزودند : امروزه ديگر هيچ تضادي بين منافع كارگر و كارفرما وجود ندارد . چون با حفظ اصل توليد ، كارگر مي تواند ادامه فعاليت دهد از سوي ديگر نيز اگر كارگر نباشد ، توليدي محقق نمي شود .&lt;br /&gt;&lt;br /&gt;نمايندگان كارگران همچنين پيمانهاي دسته جمعي را يك ظرفيت مهم قانون كار دانسته و خواستار توجه به اجراي بيشتر آن شد .&lt;br /&gt;نمايندگان كارفرمايان نيز در اين جلسه با استقبال از شيوه اصلاح قانون كار ، بازنگري در آن را ضروري دانسته و توجه به نظر شركاي اجتماعي و حصول اجماع در اصلاح قانون مزبور را مورد تاكيد قرار دادند.&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4601736074789237285?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4601736074789237285/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4601736074789237285&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4601736074789237285'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4601736074789237285'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/08/blog-post_17.html' title='قانون كار با هدف پايداري مشاغل اصلاح می شود'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1810754158326461574</id><published>2011-08-17T01:04:00.003+04:30</published><updated>2011-08-17T01:14:31.905+04:30</updated><title type='text'>هشدار ایمنی در خصوص بالارفتن از تیرهای برق , برق گرفتگی و سقوط</title><content type='html'>&lt;p align="right"&gt;متاسفانه اخیراً حوادث زیادی از برق گرفتگی و سقوط ناشی از بالا رفتن غیر مجاز افراد ناآگاه از تیرهای برق و نزدیک شدن به متعلقات ترانسفورماتورهای هوایی برق گزارش شده است.&lt;br /&gt;افرادی که بعضاً به منظور دستکاری و سرقت از تیرهای برق صعود می کنند و حتی افرادی که نظر خیر دارند و به منظور نصب پارچه نوشته و پرچم در مراسم های جشن و یا عزاداری از این تیرها بالا می روند و قصد دارند این اشیاء را در بالاترین ارتفاع نصب کنند و از خطری که آنان را تهدید می کند اطلاعی ندارند.&lt;br /&gt;&lt;br /&gt;همه این افراد از این موضوع غافل هستند که خطوط و تجهیزات برق دارای ولتاژ بیست هزار ولت دارای حوزه الکتریکی هستند و قبل از تماس مستقیم با آنها و حتی با فاصله از ترانسفورماتور ، می توانند دچار برق گرفتگی شوند و طبیعی است که در این شرایط اگر فرد از این موضوع جان سالم به در ببرد , از پیامد دوم یعنی سقوط ،بعید است دوباره شانس بیاورد و آسیبی نبیند.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;جهت اطلاع عرض کنم برق گرفتگی های ولتاژ بالا ( بیست هزار ولت ) پیامدهای بسیار ناگواری در پی داشته و معمولاً جریان برق ، بیشتر ارگان های داخلی بدن را ( در مسیری که جریان برق از بدن عبور می کند ) از بین می برد و احتمال اینکه فرد زنده بماند خیلی کم است و در صورت زنده ماندن در اکثر موارد همراه با قطع اعضاء بدن ( مثل یک دست , دو دست و حتی پا ) همراه خواهد بود.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;در آمارها کمتر مشاهده شده که در این خصوص کسی دچار حادثه شود و مشکل جدی برایش پیش نیامده باشد. کسی که تا حالا شانس آورده، در حوادث اخیر یک نفر بوده که پس از برق گرفتگی و سقوط از تیر برق 12 متری ( که قصد نصب پرچم هیئت را داشته )، دست خود را به دلیل برق گرفتگی ولتاژ بالا ( بیست هزار ولت ) از دست داده است.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;لذا مجدد تاکید می گردد , به هر دلیل از بالا رفتن از تیرهای برق و نزدیک شدن به ترانسفورماتورهای برق ، که دارای ولتاژ قوی هستند پرهیز نموده و در صورت مشاهده، از این اقدام جلوگیری نمایید و یا مراتب را سریعاً قبل از اینکه حادثه ای روی دهد، به شماره تلفن فوریت های برق یعنی 121 اطلاع دهند. &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1810754158326461574?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1810754158326461574/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1810754158326461574&amp;isPopup=true' title='1 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1810754158326461574'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1810754158326461574'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/08/blog-post.html' title='هشدار ایمنی در خصوص بالارفتن از تیرهای برق , برق گرفتگی و سقوط'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-382022811020893127</id><published>2011-07-22T12:49:00.002+04:30</published><updated>2011-07-22T12:52:46.303+04:30</updated><title type='text'>A Book about Electrical Safety Equipment</title><content type='html'>&lt;a href="http://1.bp.blogspot.com/-EPR9AKw_da4/Tiky0pu__MI/AAAAAAAAFVY/6IDedwwpcFI/s1600/12web.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 334px; DISPLAY: block; HEIGHT: 229px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5632088689141087426" border="0" alt="" src="http://1.bp.blogspot.com/-EPR9AKw_da4/Tiky0pu__MI/AAAAAAAAFVY/6IDedwwpcFI/s320/12web.jpg" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-382022811020893127?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/382022811020893127/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=382022811020893127&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/382022811020893127'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/382022811020893127'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/07/electrical-safety-equipment-book.html' title='A Book about Electrical Safety Equipment'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/-EPR9AKw_da4/Tiky0pu__MI/AAAAAAAAFVY/6IDedwwpcFI/s72-c/12web.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8243115052710616990</id><published>2011-07-22T12:39:00.002+04:30</published><updated>2011-07-22T12:44:17.343+04:30</updated><title type='text'>Process of Achieving an Electrically Safe Work Condition</title><content type='html'>&lt;div dir="ltr" align="left"&gt;&lt;strong&gt;1-Identify all possible sources of electric supply.&lt;br /&gt;&lt;/strong&gt;Care should be taken to identify the possible presence of secondary sources.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;2-Properly interrupt the load current(s) and open the disconnecting device(s).&lt;br /&gt;&lt;/strong&gt;Not all disconnecting devices are rated to interrupt load currents; this should only be done with a properly rated device.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;2-Verify deenergization through visual inspection of the disconnect contacts.&lt;br /&gt;&lt;/strong&gt;Disconnecting means may sometimes fail to open all phase conductors when the handle is operated,&lt;br /&gt;so it is necessary to verify physical contact separation. If this requires removing the disconnect&lt;br /&gt;door or cover, appropriate PPE must be used.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;3-Apply lockout/tagout devices.&lt;br /&gt;&lt;/strong&gt;This should be done in accordance with a formally established company policy.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;4-Use a voltage detector to test each conductor to which the worker may be exposed in order to verify deenergization.&lt;br /&gt;&lt;/strong&gt;The voltage detecting device must be functionally tested both before and after taking the measurements in order to ensure that it is working satisfactorily.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;5-Circuit parts with induced voltages or stored electrical energy must be grounded.&lt;br /&gt;&lt;/strong&gt;If the conductors being deenergized could contact other energized conductors or circuit parts, grounding devices rated for the available fault duty should be applied. &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8243115052710616990?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8243115052710616990/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8243115052710616990&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8243115052710616990'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8243115052710616990'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/07/process-of-achieving-electrically-safe.html' title='Process of Achieving an Electrically Safe Work Condition'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6169096149865706500</id><published>2011-07-22T12:36:00.000+04:30</published><updated>2011-07-22T12:39:08.813+04:30</updated><title type='text'>Training Requirements for Electrical Safety-Related Work Practices</title><content type='html'>&lt;div dir="ltr" align="left"&gt;&lt;/div&gt;&lt;br /&gt;&lt;p dir="ltr" align="left"&gt;Employees who may be exposed to electrical hazards must be specifically trained to understand the&lt;br /&gt;hazards associated with electrical energy as well as the safety-related work practices and procedures required to provide protection from them. The level of training provided determines the tasks that an employee is qualified to perform.&lt;br /&gt;&lt;br /&gt;Only specially ‘Qualified Persons’ may perform work on or near exposed and energized electrical conductors or circuit parts. The training requirements include:&lt;br /&gt;&lt;br /&gt;How to recognize the potential hazards that exist&lt;br /&gt;How to distinguish energized from non-energized parts&lt;br /&gt;How to determine the voltage of exposed energized electrical conductors&lt;br /&gt;The relationship between the hazard and potential injury&lt;br /&gt;How to avoid exposure to the hazards&lt;br /&gt;How to select appropriate personal protective equipment&lt;br /&gt;Specific work practices and procedures to be followed&lt;br /&gt;Emergency procedures for assisting victims of electrical incidents&lt;br /&gt;How to perform a hazard/risk analysis&lt;br /&gt;How to determine approach and flash protection boundaries&lt;br /&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6169096149865706500?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6169096149865706500/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6169096149865706500&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6169096149865706500'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6169096149865706500'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/07/training-requirements-for-electrical.html' title='Training Requirements for Electrical Safety-Related Work Practices'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8570911147547262265</id><published>2011-07-15T14:06:00.000+04:30</published><updated>2011-07-15T14:07:13.878+04:30</updated><title type='text'>مرگ ۲۶۶۶ ایرانی به وسیله آب، گاز و برق</title><content type='html'>روزنامه شرق نوشت:&lt;br /&gt;&lt;br /&gt;بر اساس آخرین آمارهای اعلام شده از سوی سازمان پزشکی قانونی کشور در سال ۸۹ ، ۷۵۰ نفر بر اثر برق گرفتگی، ۷۶۹ نفر بر اثر گاز گرفتگی و یک هزار و ۱۳۴ نفر نیز به علت غرق شدن جان خود را از دست داده اند.&lt;br /&gt;&lt;br /&gt;غیر از بالا بودن این آمار نسبت به میانگین جهانی آنچه مسئله را به مراتب عجیب تر می کند این است که بدانیم آمار کشته شدگان برق گرفتگی سال ۸۹ نسبت به سال ۸۸ با رشد ۶،۴ درصدی، مرگ ناشي از گازگرفتگي با افزايش ‌۷.۱ درصدي و آمار مرگ ناشي از غرق‌شدگي در مقايسه با مدت مشابه سال قبل رشد ۱۲.۶ درصدی داشته است.&lt;br /&gt;&lt;br /&gt;برق در دهه هشتاد ۵۸۹۸ ایرانی را کشت&lt;br /&gt;&lt;br /&gt;البته سال ۸۹ در زمینه تلفات برق گرفتگی رکورد دار همه ی سال های دهه ۸۰ است به شکلی که این آمار نسبت به یک دهه قبل ۸۰ درصد افزایش پیدا کرده است. سال ۸۸ آمار کشته شدگان برق گرفتگی ۷۰۵ بود و تهران با ۱۶۶ کشته، خوزستان با ۹۹ کشته و فارس با ۵۸ کشته در رتبه‌های اول تا سوم استان‌های پر حادثه خیز در برق گرفتگی در کشور بوده اند.&lt;br /&gt;&lt;br /&gt;۱۳۱ سال پس از آنکه توماس ادیسون در سال ۱۸۸۰ نخستین نیروگاه مولد برق را در نیویورک، راه اندازی کرد جریان برق همچنان در ایران تلفات جانی به بار می آورد، آنطور که آمارهای سازمان پزشکی قانونی نشان می دهد در سال ۸۹ هر ۳۰ استان کشور از این تلفات بی بهره نبوده اند. آمار کشته‌های برق گرفتگی استان‌های کشور علاوه بر تهران، خوزستان و فارس در دیگر استان ها اینگونه بود؛ اصفهان ۴۹، خراسان رضوی ۳۵، کرمان۲۸، مازندران ۲۷، آذربایجان شرقی ۲۵، سیستان و بلوچستان ۲۴، هرمزگان ۲۰، گلستان ۱۸، کرمانشاه ۱۷، بوشهر ۱۶، قزوین ۱۵، قم ۱۵، همدان ۱۵، آذربایجان غربی۱۴، لرستان ۱۴، یزد ۱۴، گیلان ۱۳، سمنان ۱۲، زنجان ۹، کهگیلویه و بویر احمد ۹، خراسان شمالی ۸، چهارمحال بختیاری ۷، اردبیل ۶، مرکزی ۶، کردستان ۵، ایلام ۳ و خراسان جنوبی ۳ نفر کشته است. بر اساس اعلام سازمان پزشکی قانونی کشور آمار کشته‌های برق گرفتگی کشور به ترتیب ۴۲۳ کشته در سال ۸۰ ، ۴۲۷ کشته در سال ۸۱، ۴۷۴ کشته در سال ۸۲، ۵۵۴ کشته در سال ۸۳ ، ۵۸۹ کشته در سال ۸۴ ، ۶۷۵ کشته در سال ۸۵، ۶۵۱ کشته در سال ۸۶، ۶۵۰ کشته در سال ۸۷ ، ۷۰۵ کشته در سال ۸۸ و در نهایت ۷۵۰ کشته در سال ۸۹ بوده است که مجموع این کشته ها ۵۸۹۸ است.&lt;br /&gt;&lt;br /&gt;قاتل خاموش&lt;br /&gt;&lt;br /&gt;تلفات گاز گرفتگی هم مانند آمار فوت شدگان برق گرفتگی که در سال ۸۸ به ۷۶۹ نفر می رسید در سال ۸۹ با افزایش ‌۷.۱ درصدي به ۷۸۲ نفر در سال ۸۹ رسید. در این سال بيشترين رقم مرگ ناشي از گازگرفتگي ۲۰۹ نفر در استان تهران بود. اصفهان با ۸۲ نفر، استان آذربايجان شرقي با ۵۸ نفر و استان فارس با ۵۱ نفر کشته شده بيشترين آمار گازگرفتگي را داشته اند. همچنین استانهاي هرمزگان با مرگ يك نفر، بوشهر با دو نفر، ايلام با ۴ نفر و استان‌هاي قم و كهگيلويه و بويراحمد مشتركا با ۵ نفر كمترين تلفات ناشي از گازگرفتگي را در اين سال به خود اختصاص داده‌اند. در دهه ۸۰ بيشترين مرگ ناشي از گازگرفتگي مربوط به سال ۱۳۸۶ با آمار مرگ يك هزار و ۲۴ نفر بوده است.&lt;br /&gt;&lt;br /&gt;قاتل: مایع حیات&lt;br /&gt;&lt;br /&gt;اگر چه در میان کشورهای کره زمین ایران از سرزمین های خشک و بیابانی محسوب می شود اما علاوه بر گاز و برق، آب هم قاتل ایرانیان است، آمارهای پزشکی قانونی نشان می دهد در سال ۱۳۸۹ يكهزار و ۱۳۴ نفر بر اثر غرق‌شدگي در آب جان خود را از دست دادند، این در حالی است که در سال ۱۳۸۸ بر اثر غرق‌شدگي يكهزار و ۷ نفر در كشور جان خود را از دست داده بودند، آمار مرگ ناشي از غرق‌شدگي در سال گذشته در مقايسه با مدت مشابه سال قبل ۱۲.۶ درصد افزايش و در مقايسه با سال ۸۷ با كاهش ۳.۱۳ درصدي مواجه بوده است. در سال ۸۹ كمترين رقم مرگ ناشي از غرق‌شدگي با مرگ ۳نفر به استان‌هاي خراسان شمالي و خراسان جنوبي مربوط است و بيشترين رقم غرق‌شدگي در سال گذشته نیز به ترتيب با مرگ ۲۰۴نفر مربوط به استان خوزستان و پس از آن با مرگ ۱۹۴ نفر به استان مازندران می رسد.&lt;br /&gt;&lt;br /&gt;سال خشن ۸۹&lt;br /&gt;&lt;br /&gt;البته مورد عجیب ۸۹ تنها به افزایش درصد کشته شدگان آب و برق و گاز خلاصه نمی شود، چرا که در زمینه تلفات تصادفات رانندگی نیز با افزایش ۲.۱ درصدی ۲۳ هزار و ۲۴۹ نفر جان خود را در جاده های کشور از دست دادند. همچنین تعداد مراجعین نزاع در سال ۱۳۸۹ نیز با افزایش ۷.۶ درصدی نسبت به سال قبل از آن به رقم ۶۲۹ هزار و ۳۶ نفر در این سال رسید. این در حالی بود که در سال ۱۳۸۸ تعداد مراجعین نزاع به مراکز پزشکی قانونی سراسر کشور ۵۸۵ هزار و ۵۰۹ نفر بود، آمار کشته شدگان ناشی از سلاح سرد که در سال هشتاد و هشت ۹۷۶ نفر بود نیز با رشدی ۱۰ درصدی در سال ۸۹ به یک هزار و ۹۳ نفر رسید. عجیب تر آنکه سال پایانی دهه ۸۰ حتی رکورد بیشترین تعداد مراجعین نزاع را با رقم ۶۲۹ هزار و ۳۶ نفر نسبت به همه سال های پیشین به نام خود ثبت کرده است.&lt;br /&gt;&lt;br /&gt;با در کنار هم گذاشتن این امار باید گفت ایرانیان سال پایانی دهه هشتاد را به خونین ترین شکل ممکن پشت سر گذاشته اند، حالا تنها سه ماه از آغاز دهه ۹۰ خورشیدی می گذرد و تاکنون آماری در زمینه تلفات آب ، برق ، گاز ، تصادف و نزاع منتشر نشده است، خدا دهه ۹۰ را به خیر بگذراند!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8570911147547262265?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8570911147547262265/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8570911147547262265&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8570911147547262265'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8570911147547262265'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/07/blog-post_10.html' title='مرگ ۲۶۶۶ ایرانی به وسیله آب، گاز و برق'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3056194020024125472</id><published>2011-07-15T14:04:00.001+04:30</published><updated>2011-07-15T14:04:52.617+04:30</updated><title type='text'>راهکارهاي کليدي براي کاهش خطر امواج تلفن هاي همراه و بي سيم</title><content type='html'>يک کارشناس مخابراتي با تاکيد بر مضرات گوشي ‌هاي همراه براي سلامتي انسان، درباره تلفن‌هاي بي‌سيم خانگي هم مدعي شد: مشکلات ناشي از استفاده از تلفن‌هاي خانگي بي‌سيم از گوشي‌هاي تلفن همراه بيشتر است؛ پس بهتر است در خانه از گوشي‌هاي سيمي استفاده کنيم.مهدي موسويان انارکي در گفت‌وگو با ايسنا، گفت : در حالت کلي گوشي تلفن همراه در حالت روشن - حين مکالمه و غير از آن - در حال ارسال و دريافت اطلاعات از طريق امواج الکترومغناطيس با ايستگاه BTS است که با راهکارهاي ساده مي‌توان از مضرات آن کاست. يکي از اين راهکارها استفاده از بعضي تجهيزات مانند هندزفري و بلندگو هنگام مکالمه است.اين استاد دانشگاه در ادامه اظهار داشت: در کشورهاي مختلف دنيا با تدوين قوانين خاص براي توليد و واردات گوشي‌هاي تلفن همراه و هم‌چنين نظارت بر نحوه پياده‌سازي و طراحي شبکه‌هاي تلفن همراه سعي مي‌شود از عوارض اين دستگاه‌ها بر سلامت جامعه کاسته شود. به دليل پيچيدگي و فني بودن اين موضوع نمي‌توان از استفاده کننده عادي انتظار داشت تا در موقع خريد گوشي تلفن همراه بعضي پارامترهاي مربوط به تاثير گوشي بر سلامت شخص را در نظر بگيرد؛ در اين راستا مي‌توان آگاهي افراد را بالا برد و يا واردات گوشي‌هاي غيراستاندارد را به داخل کشور ممنوع کرد. اين کارشناس مخابراتي بيان کرد: در خريد گوشي تلفن همراه بايد دقت شود و گوشي با ( SAR (Specific Absorption Rateکمتر انتخاب شود، استفاده از تلفن ثابت و يا پيام کوتاه به جاي زنگ زدن با تلفن همراه و کاهش تعداد و دوره مکالمات تا حد مطلوب کمتر از 3 دقيقه مي تواند به کاهش مضرات کمک کند. دور کردن 2 تا 3 سانتي متري گوشي تلفن همراه حين مکالمه و يا استفاده از بلندگو و هندز فري مي تواند در اين زمينه کارساز باشد. همچنين گوشي تلفن همراه را در هنگام خواب کنار خود قرار ندهيد زيرا اين دستگاه‌ها دائم با ايستگاه بي تي اس، در حال رد و بدل پيام‌هاي کنترلي و در نتيجه انتشار امواج هستند.به گفته وي افراد نبايد در اماکني که سيگنال ضعيف است از گوشي همراه خود استفاده کنند زيرا اغلب گوشي‌هاي تلفن همراه در اين مکان‌ها توان بيشتري براي ارتباط با BTS به کار مي‌گيرند.همچنين بايد از گذاشتن گوشي در جيب پيراهن، نزديک قلب و يا بستن آن به کمربند و نزديک کليه‌ها خودداري کرد و بهترين مکان براي حمل گوشي تلفن همراه درون کيف دستي و استفاده از هندزفري بلوتوث است.وي هم‌چنين مدعي شد که مضرات استفاده از تلفن‌هاي خانگي بي‌سيم از گوشي‌هاي تلفن همراه بيشتر است؛ پس بهتر است در خانه از گوشي‌هاي سيمي استفاده کنيد. به گفته وي، در گوشي‌هاي تلفن همراه که جک هندز فري سيمي آن نزديک آنتن گوشي است مضرات استفاده از هندزفري سيمي بيشتر از مضرات خود گوشي تلفن همراه است.موسويان درباره استانداردهاي لازم براي ايمني‌سازي امواج پراکنده در محيط براي برقراري ارتباطات سيستمي، اظهار کرد: به طور کلي ميزان جذب امواج الکترومغناطيس در بدن که نتيجه آن بالا رفتن حرارت نقطه‌اي بافت‌هاي بدن و آسيب رسيدن به اين بافت‌هاست، بايد از حد معيني کمتر باشد و با فاصله گرفتن از فرستنده مي‌توان اين مقدار جذب انرژي را کم کرد. وي گفت: درباره BTSهاي تلفن همراه نيز براساس توصيه‌هاي ارائه شده توسط مراکز تحقيقاتي و در بعضي موارد شرکت‌هاي سازنده دستگاه‌ها، بهتر است بي تي اس‌هاي با توان بالا (بي تي اس ماکرو) در مجتمع‌هاي مسکوني با جمعيت زياد و يا در مدارس و يا در مکان‌هاي شلوغ نصب نشود و يا با دقت خاصي طراحي آن انجام شود؛ به طوري که سطح سيگنال دريافتي در مکان‌هايي که مردم در رفت و آمدند و يا زندگي مي‌کنند از مقدار مشخصي بيشتر نباشد.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3056194020024125472?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3056194020024125472/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3056194020024125472&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3056194020024125472'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3056194020024125472'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/07/blog-post_15.html' title='راهکارهاي کليدي براي کاهش خطر امواج تلفن هاي همراه و بي سيم'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7478385159010574952</id><published>2011-07-15T14:01:00.001+04:30</published><updated>2011-07-15T14:03:29.244+04:30</updated><title type='text'>علل حادثه برق گرفتگی پالایشگاه تهران بررسی می‌شود</title><content type='html'>معاون وزیر نفت در امور پالایش و پخش علیرضا ضیغمی از بررسی علل حادثه برق گرفتگی پالایشگاه تهران خبر داد و گفت: با خاطیان این حادثه برخورد جدی خواهد شد.&lt;br /&gt;          &lt;br /&gt;&lt;br /&gt;به گزارش خبرنگار شانا، مدیرعامل شرکت ملی پالایش و پخش فرآورده های نفتی ایران در دستوری خطاب به مدیریت اچ‌اس‌یی این شرکت ضمن تاکید بر ضرورت رعایت کامل مسائل ایمنی در بخش های مختلف شرکت ملی پالایش و پخش، بر برخورد سریع با خاطیان حادثه برق گرفتگی پالایشگاه شهید تندگویان تهران تاکید کرد.&lt;br /&gt;&lt;br /&gt;علیرضا ضیغمی در این نامه، رعایت نکات ایمنی را یکی از مهمترین سرفصل های فعالیت در واحدهای عملیاتی این شرکت اعلام و تصریح کرد: نظارت بر روند اجرای اصول ایمنی در پالایشگاه ها و پروژه های در حال اجرای این شرکت باید با دقت بیشتری انجام شود تا شاهد تکرار حوادث این چنینی در صنعت نفت نباشیم.&lt;br /&gt;&lt;br /&gt;بر پایه این گزارش، پیش ازظهر روز چهارشنبه (22تیر) در حین انجام تعمیرات در سوئیچ برق یکی از واحدهای پالایشگاه نفت تهران، سه نفر از کارکنان این مجموعه پالایشی به نام های مصطفی رستگاری، صادق امیری و مهدی بابایی دچار سوختگی از 10 تا 50 درصد شدند.&lt;br /&gt;&lt;br /&gt;بر اساس اطلاعات منتشر شده از سوی روابط عمومی پالایشگاه تهران، این حادثه منجر به فوت هیچ کدام از کارکنان پالایشگاه تهران نشده است و هم اکنون وضع عمومی حادثه دیدگان پالایشگاه تهران مطلوب است و این افراد برای مداوا به بیمارستان منتقل شده اند.&lt;br /&gt;&lt;br /&gt;این تعمیرات به صورت روزانه در واحدهای مختلف پالایشگاه انجام می شود ولی در جریان عملیات روز چهارشنبه تعمیرات در سویچ برق پالایشگاه، جرقه ایجاد و با توجه به بالا بودن فشار ولتاژ برق منجر به سوختگی کارکنان این پالایشگاه شد.&lt;br /&gt;بر پایه این گزارش، این حادثه هیچ خللی در عملیات پالایشگاه ایجاد نکرده است و این پالایشگاه با توان عملیاتی پالایش روزانه 240 تا 250 هزار بشکه نفت خام در مدار فعالیت قرار دارد.&lt;br /&gt;&lt;br /&gt;شبکه اطلاع رسانی نفت و انرژی&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7478385159010574952?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7478385159010574952/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7478385159010574952&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7478385159010574952'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7478385159010574952'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/07/blog-post.html' title='علل حادثه برق گرفتگی پالایشگاه تهران بررسی می‌شود'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7888119174075479873</id><published>2011-06-09T13:00:00.000+04:30</published><updated>2011-06-09T13:01:32.859+04:30</updated><title type='text'>برق گرفتگي و ۳ حادثه تاسف بار هنگام سرويس کولر آبي</title><content type='html'>هنگام سرويس کولر آبي بايد ابتدا جريان برق را با اطلاع همه ساکنان ساختمان از کنتور قطع کنيم.&lt;br /&gt;&lt;br /&gt;هموطن آنلاين _غلامرضا تديني راد _گرماي هوا بي رحمانه به صورت آسمان سيلي مي زد و آفتاب سوزان با نسيمي داغ و طاقت فرسا ترانه خواني مي کرد. با گرم شدن هوا شهروندان زيادي دست به کار شده اند تا کولر خانه خود را به راه بيندازند و در سايه اي سرد و دلچسب پناه گيرند.&lt;br /&gt;اما افسوس که شبح مرگ در ظهر يکي از روزهاي گرم ارديبهشت ماه ۳ تن را به طرز وحشتناکي به آغوش سايه سرد مرگ کشاند و خانواده هاي اين افراد را داغدار کرد.&lt;br /&gt;اين ۳ حادثه تاسف بار در کمتر از يک ساعت و در ۳ شهرستان خراسان رضوي اتفاق افتاد. در حادثه اول جوان ۲۵ ساله اي به نام محسن در شهرستان بجستان براي سرويس کولر آبي خانه به بالاي پشت بام رفت اما او هنگام کار، دچار برق گرفتگي شديدي شد و به طرز دلخراشي دچار سوختگي شد و جان خود را از دست داد. پس از گذشت چند دقيقه پيرمرد ۷۱ ساله اي در شهرستان گناباد هنگام انجام سرويس کاري کولر دچار برق گرفتگي شد و او نيز جان باخت. اما در سومين حادثه غم انگيز، جوان ۲۴ ساله اي به نام محسن که در شهرستان تربت حيدريه زندگي مي کرد دچار برق گرفتگي شد. محسن تنها پسر خانواده بود و پس از مرگ پدرش، سرپرستي خانه را به دوش مي کشيد. او نيز هنگام سرويس کولر آبي دچار برق گرفتگي و سوختگي شديد شد و در برابر چشمان بهت زده خانواده اش جان خود را از دست داد. اطرافيان محسن با آه و ناله جسد او را به آغوش خاک سرد سپردند.&lt;br /&gt;مسئول آموزش هاي تخصصي و رئيس ايستگاه ۶ سازمان آتش نشاني مشهد با ابراز تاسف از اين ۳ حادثه غم بار گفت: هنگام سرويس کولر آبي بايد ابتدا جريان برق را با اطلاع همه ساکنان ساختمان از کنتور قطع کنيم و اگر در منزل تنها هستيم با نصب برگه يادداشت بر روي کنتور علت قطع برق را به اطلاع افرادي که ممکن است وارد ساختمان شوند برسانيم.&lt;br /&gt;سرآتشيار محمدجواد قائمي افزود: در اتصالات کولر به طور حتم بايد از ترمينال استفاده شود و نسبت به عايق بندي کامل اقدام کنيم. امتحان بدنه کولر با فازمتر بعد از اتمام کار و در زمان برقراري مجدد جريان برق نيز ضروري است. قائمي خاطرنشان کرد: گاهي در زمان استفاده از کولر متوجه مي شويم که دستگاه برودت لازم را ندارد در اين زمان نيز بايد ابتدا بدنه کولر را با فازمتر کنترل و سپس دريچه آن را باز کنيم.&lt;br /&gt;وي تاکيد کرد: در صورتي که نسبت به مهارت برق اطلاعات لازم را نداريم بايد از سرويس کار متخصص براي سرويس کاري کولر استفاده کنيم و پيشنهاد آخر به شهروندان نصب «فيوز محافظ جان» در تابلوي برق خانه است چرا که اين فيوز، در صورت نشتي جريان برق، در کمتر از ۲ صدم ثانيه جريان برق را به طور خودکار قطع و از برق گرفتگي پيشگيري مي کند.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7888119174075479873?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7888119174075479873/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7888119174075479873&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7888119174075479873'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7888119174075479873'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/06/blog-post_09.html' title='برق گرفتگي و ۳ حادثه تاسف بار هنگام سرويس کولر آبي'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1460242104709625017</id><published>2011-06-09T12:58:00.001+04:30</published><updated>2011-06-09T13:00:05.696+04:30</updated><title type='text'>يك نوجوان 17 ساله مشهدي به علت اصابت صاعقه جان باخت.</title><content type='html'>&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;رييس اورژانس 115 مشهد گفت : يك نوجوان 17 ساله مشهدي جمعه شب به علت اصابت صاعقه جان باخت.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;دكتر محمدرضا مهري روز شنبه در گفت و گو با ايرنا افزود : اين نوجوان به همراه تعدادي از دوستانش، مشغول بازي فوتبال بود كه دچار صاعقه زدگي شد.وي گفت : اگر چه پس از اعلام اين حادثه بلافاصله آمبولانس اورژانس 115 در محل حادثه حاضر شد ، اما نوجوان مشهدي بر اثر صاعقه زدگي در دم جان باخته بود.&lt;br /&gt;&lt;br /&gt;او با اشاره به وجود آثار ورود و خروج صاعقه بر روي جسد نوجوان ، افزود : صاعقه از پشت سر اين نوجوان وارد و از پشت پاي او خارج شده بود ، به طوري كه آثار سوختگي در موهاي پشت سر جان باخته و پاي او مشهود بود.&lt;br /&gt;رييس پليس اورژانس 115 مشهد گفت : صاعقه‌ يك‌ جريان‌ الكتريكي‌ ناگهاني‌ طبيعي‌ است‌ كه‌ از جو تخليه‌ مي‌شود و در مسير خود، مقادير زيادي‌ از حرارت‌ و نور را منتقل‌ مي‌كند.&lt;br /&gt;&lt;br /&gt;وي با بيان اينكه صاعقه 125 ميليون ولت برق دارد، افزود: اين مقدار برق براي روشن كردن يك لامپ 100 وات به مدت بيش از سه ماه يا براي مصدوميت جدي يا كشتن يك نفر كافي است.&lt;br /&gt;&lt;br /&gt;او به راهكارهاي پيشگيري از اصابت صاعقه اشاره كرد و گفت: نبايد در هواي ابري - باراني كه صداي صاعقه نيز به گوش مي رسد از منزل بيرون رفت و يا در مكان هاي روباز قرار گرفت.&lt;br /&gt;&lt;br /&gt;دكتر مهري گفت : افراد براي در امان ماندن از صاعقه زدگي بايد به دنبال سرپناه باشند و چنانچه هنگام صاعقه در آب هستند بايد فوري از آن خارج شوند.اگر افراد هنگام رعد و برق ، بار الكتريكي را حس كردند به طوري كه موهاي سرشان سيخ سيخ شد يا در پوست خود احساس مور مور كردند، ممكن است دچار صاعقه زدگي شوند و بهترين راه اين است كه فوري روي زمين دراز بكشند.&lt;br /&gt;&lt;br /&gt;www.NiceNews.IR&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1460242104709625017?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1460242104709625017/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1460242104709625017&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1460242104709625017'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1460242104709625017'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/06/17.html' title='يك نوجوان 17 ساله مشهدي به علت اصابت صاعقه جان باخت.'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7658013096461567504</id><published>2011-06-09T12:56:00.000+04:30</published><updated>2011-06-09T12:58:12.333+04:30</updated><title type='text'>Top causes of electrical fires</title><content type='html'>&lt;div dir="ltr" align="left"&gt;There are several ways you can assess your risk and make simple changes to reduce the hazards that may be present in an electrical system. By ensuring that your home undergoes a thorough electrical inspection completed by a qualified electrician before buying, selling, or remodeling a home, you can help make certain your home's electrical system operates at the highest level of safety possible.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Electrical system&lt;br /&gt;&lt;/strong&gt;According to NFPA, every year, fires that start in electrical systems or lighting equipment result in 320 civilian deaths and 830 civilian (non-firefighter) injuries, with damage to more than 24,000 homes.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Lamps, light fixtures, and light bulbs&lt;br /&gt;&lt;/strong&gt;According to the National Fire Protection Association, lamps, light fixtures, and light bulbs (28%) and fixed wiring (22%) accounted for the largest share of fires among major types of electrical distribution equipment. Cords and plugs (39%) accounted for the largest share of civilian deaths. Lamps, light fixtures, and light bulbs (30%) accounted for the largest share of civilian injuries.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Extension cords&lt;br /&gt;&lt;/strong&gt;According to NFPA, extension cord fires outnumbered fires beginning with permanent or detached (cords that can be detached from appliances) by more than two-to-one. For civilian deaths, the ratio is more than three-to-one. For civilian injuries, the ratio is more than four-to-one.&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7658013096461567504?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7658013096461567504/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7658013096461567504&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7658013096461567504'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7658013096461567504'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/06/top-causes-of-electrical-fires.html' title='Top causes of electrical fires'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3072886433145679584</id><published>2011-06-09T12:55:00.000+04:30</published><updated>2011-06-09T12:56:47.063+04:30</updated><title type='text'>برق گرفتگي سال گذشته جان 750 نفر را در كشور گرفت.</title><content type='html'>&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;سازمان پزشكي قانوني اعلام كرد:&lt;br /&gt;برق گرفتگي سال گذشته جان 750 نفر را در كشور گرفت.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;خبرگزاري فارس: بر اساس آخرين آمار سازمان پزشكي قانوني كشور 750 نفر بر اثر برق گرفتگي در سال 89 كشته شدند كه نسبت به يك دهه قبل 80 درصد افزايش يافته است.&lt;br /&gt;&lt;br /&gt;به گزارش خبرنگار بهداشت و درمان فارس، بر اساس گزارش سازمان پزشكي قانوني كشور در سال 89 بالغ بر 750 نفر بر اثر برق گرفتگي در كشور جان خود را از دست داده‌اند كه نسبت به آمار 705 كشته برق گرفتگي در سال 88 آمار كشته شدگان برق گرفتگي با رشد 6،4 درصدي مواجه شده است و تهران با 166 كشته، خوزستان با 99 كشته و فارس با 58 كشته در رتبه‌هاي اول تا سوم استان‌هاي پر حادثه خيز در برق گرفتگي در كشور به حساب مي‌آيند.&lt;br /&gt;&lt;br /&gt;آمار كشته‌هاي برق گرفتگي استان‌هاي كشور نيز به ترتيب تهران 166، خوزستان 99، فارس 58، اصفهان 49، خراسان رضوي 35، كرمان28، مازندران 27، آذربايجان شرقي 25، سيستان و بلوچستان 24، هرمزگان 20، گلستان 18، كرمانشاه 17، بوشهر 16، قزوين 15، قم 15، همدان 15، آذربايجان غربي14، لرستان 14، يزد 14، گيلان 13، سمنان 12، زنجان 9، كهگيلويه و بوير احمد 9، خراسان شمالي 8، چهارمحال بختياري 7، اردبيل 6، مركزي 6، كردستان 5، ايلام 3 و خراسان جنوبي 3 نفر كشته كه در مجموع بالغ بر 750 نفر متوفي بر اثر برق گرفتگي گزارش شده است.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;* مرگ بر اثر برق گرفتگي نيمه اول هر سال بيشتر است&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;همچنين كشته‌هاي برق گرفتگي استان‌هاي كشور در 6 ماهه نخست سال 89 با رقم 436 نفر بيشتر از كشته‌هاي برق گرفتگي در 6 ماهه دوم سال با رقم 314 نفر گزارش شده است كه بر اساس ميزان متوفيان بر حسب جمعيت به ازاي هر 100هزار نفر استان‌هاي كردستان و مركزي و خراسان جنوبي شاهد كمترين كشته‌هاي برق گرفتگي در سال 89 و استان‌هاي خوزستان، سمنان و بوشهر بيشترين آمار متوفيان را به خود اختصاص دادند.&lt;br /&gt;&lt;br /&gt;سازمان پزشكي قانوني كشور نيز اعلام كرده است كه استان‌هاي كهگيلويه و بوير احمد، هرمزگان، كرمان، قم، اصفهان، خراسان جنوبي، اصفهان و چهارمحال بختياري به ترتيب بيشترين درصد رشد متوفيان بر اثر برق گرفتگي را به نسبت مقايسه سال 89 و 88 را به خود اختصاص دادند.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;* سال 89 بيشترين متوفيان برق گرفتگي در 9 سال اخير با 750 كشته&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;بر اساس اعلام سازمان پزشكي قانوني كشور آمار كشته‌هاي برق گرفتگي كشور نيز به ترتيب سال 80 بالغ بر 423 كشته، سال 81 بالغ بر 427 كشته، سال 82 بالغ بر 474 كشته، سال 83 بالغ بر 554 كشته، سال 84 بالغ بر 589 كشته، سال 85 بالغ بر 675 كشته، سال 86 بالغ بر 651 كشته، سال 87 بالغ بر 650 كشته، سال 88 بالغ بر 705 كشته و در نهايت سال 89 نيز بالغ بر 750 نفر جان خود را بر اثر برق گرفتگي در كشور از دست دادند.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3072886433145679584?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3072886433145679584/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3072886433145679584&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3072886433145679584'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3072886433145679584'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/06/750.html' title='برق گرفتگي سال گذشته جان 750 نفر را در كشور گرفت.'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4645454774814196229</id><published>2011-06-09T12:54:00.000+04:30</published><updated>2011-06-09T12:55:00.860+04:30</updated><title type='text'>ملوان يك شناور براثر برق گرفتگي دربندر نخل تقي شهرستان کنگان جان باخت</title><content type='html'>کنگان نیوز: يك ملوان اهل بندرنخل تقي بخش عسلويه روزسه شنبه درحين كار روي شناور باري در ساحل اين بندر بر اثر برق گرفتگي جان خود را از دست داد.&lt;br /&gt;' به گزارش کنگان نیوز و به نقل از ایرنا؛ هاشم پرو' ملوان 40 ساله ای كه روي شناور باري که براي تعميرات دركنار ساحل پهلو گرفته بود، مشغول كار بود، به علت برخورد با سيم برقي كه براي استفاده به كنار اين شناور كشيده شده بود ، دچار حادثه شد.&lt;br /&gt;پزشك كشيك درمانگاه صنعت نفت منطقه ويژه اقتصادي انرژي پارس در باره این فرد حادثه دیده که به آنجا منتقل شده بود،گفت: مصدوم دچار ايست قلبي و تنفس، ناشي از شوك الكتريكي شده بود و با توجه به تلاش دو ساعته كادرپزشكي اين درمانگاه براي احياي قلب، متاسفانه بيمار فوت شد .&lt;br /&gt;دكتر قهرمان افزود: چنانچه امداد هاي اوليه احياي قلب و عروق توسط اطرافيان در مورد اين فرد حادثه ديده انجام مي شد احتمال زنده ماندن بيمار وجود داشت.&lt;br /&gt;وي بيان كرد: در اين منطقه كه احتمال خطر و حوادث بالاست ، افراد مي توانند با بهره گيري از كمك هاي اوليه امداد و نجات در حوادث مختلف به جاي ابراز هيجانات جانبي جان افراد مصدوم را نجات دهند .&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4645454774814196229?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4645454774814196229/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4645454774814196229&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4645454774814196229'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4645454774814196229'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/06/blog-post.html' title='ملوان يك شناور براثر برق گرفتگي دربندر نخل تقي شهرستان کنگان جان باخت'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1621124582943704487</id><published>2011-04-14T16:29:00.000+04:30</published><updated>2011-04-14T16:30:18.905+04:30</updated><title type='text'>مانور مشترک آتش‌نشاني و شرکت برق شرق تهران</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;خبرگزاري آريا- براي ايجاد هماهنگي هر چه بيشتر ميان سازمان‌هاي ذيربط در اجراي عمليات نجات افراد ي که در آتش‌سوزي‌ها دچار برق گرفتگي مي‌شوند، مانور مشترکي اجرا شد.&lt;br /&gt;به گزارش آريا، اين مانورکه در آن آتش‌نشانان ايستگاه‌هاي 57، 56 و 92 منطقه 3 عمليات سازمان آتش‌نشاني تهران، ماموران شرکت برق منطقه شرق تهران و ستاد بحران منطقه 4 شهرداري تهران شرکت داشتند در منطقه تهران پارس و خيابان اتحاد برگذار شد.&lt;br /&gt;امير مهدياني معاون منطقه 3 عمليات سازمان آتش‌نشاني گفت: اين مانوربراي افزايش توان عملياتي آتش‌نشانان و ايجاد هماهنگي بيشتر همچنين آشنايي با حوادث ناشي ازبرق طبق سناريوي از پيش تعيين شده با موفقيت انجام شد.&lt;br /&gt;وي افزود: آتش‌نشانان دراين مانور عمليات امداد و نجات را در آتش‌سوزي فرضي در مورد يکي از ماموران شرکت برق که هنگام کار بر روي بالابر در ارتفاع 5متري از سطح زمين دچار برق گرفتگي شده بود با موفقيت اجرا کردند.&lt;br /&gt;آتش‌نشانان با بکارگيري تجهيزات ويژه خاموش کننده و ايمني و با رعايت اصول ايمني فرد برق گرفته را از ميان سبد بالابر به سطح زمين انتقال دادند تا به مرکز درماني اعزام شود.&lt;br /&gt;به گزارش پايگاه خبري 125، مهدياني افزود: آتش‌نشانان همچنين عمليات خاموش کردن آتش‌سوزي فرضي در پست برق 20 کيلو ولتي را نيز با در نظر گرفتن خطرات برق فشار قوي انجام دادند.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1621124582943704487?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1621124582943704487/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1621124582943704487&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1621124582943704487'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1621124582943704487'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/04/blog-post_8414.html' title='مانور مشترک آتش‌نشاني و شرکت برق شرق تهران'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6392978464376233637</id><published>2011-04-14T16:16:00.003+04:30</published><updated>2011-04-14T16:23:20.893+04:30</updated><title type='text'>سیم کشی نا ایمن برق، حادثه آفرید</title><content type='html'>&lt;a href="http://2.bp.blogspot.com/-3jRHDeOKTO0/Tabf6amsSpI/AAAAAAAAFRc/R2toZnQWpDU/s1600/%25D8%25A2%25D8%25AA%25D8%25B4.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 320px; DISPLAY: block; HEIGHT: 240px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5595405781721434770" border="0" alt="" src="http://2.bp.blogspot.com/-3jRHDeOKTO0/Tabf6amsSpI/AAAAAAAAFRc/R2toZnQWpDU/s320/%25D8%25A2%25D8%25AA%25D8%25B4.jpg" /&gt;&lt;/a&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;سیم کشی نا ایمن برق باعث بروز اتصالی و ایجاد آتش‌سوزی در آشپزخانه تالار پذیرایی شد و آتش‌نشانان را به محل حادثه کشاند.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;بنا به این گزارش ، رخداد این آتش‌سوزی ساعت 03/24 دقیقه بامداد امروز از طریق سامانه 125 به ستاد فرماندهی آتش‌نشانی تهران اعلام شد و این ستاد بی‌درنگ آتش‌نشانان ایستگاه 6 را به محل حادثه در تهرانپارس، خیابان 184 شرقی روانه کرد.&lt;br /&gt;رمضان بشیریان فرمانده آتش‌نشانان گفت: آتش‌سوزی در اتاقکی به متراژ 12 متر مربع در پشت بام ساختمان این تالار که از آن به عنوان آشپزخانه استفاده می‌شد رخ داده بود که آتش‌نشانان با قطع کردن جریان برق و گاز ساختمان و استفاده از تجهیزات ایمنی و خاموش کننده آتش‌سوزی را خاموش و با هواکش‌های قوی دود را از محل خارج کردند.&lt;br /&gt;این فرمانده آتش‌نشانی علت بروز آتش‌سوزی را ایجاد اتصالی در سیم‌های برق اعلام کرد.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6392978464376233637?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6392978464376233637/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6392978464376233637&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6392978464376233637'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6392978464376233637'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/04/blog-post_7360.html' title='سیم کشی نا ایمن برق، حادثه آفرید'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/-3jRHDeOKTO0/Tabf6amsSpI/AAAAAAAAFRc/R2toZnQWpDU/s72-c/%25D8%25A2%25D8%25AA%25D8%25B4.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5719054815734109328</id><published>2011-04-14T16:10:00.002+04:30</published><updated>2011-04-14T16:14:22.023+04:30</updated><title type='text'>فروشگاه لوازم منزل در میان شعله‌های آتش ناشی از بروز اتصالی در سیم‌های برق گرفتار و دچار خسارت مالی شد.</title><content type='html'>&lt;a href="http://2.bp.blogspot.com/-bikFzWOnr6w/TabeADKBIbI/AAAAAAAAFRU/_Y-pST4XZjU/s1600/35107_634381195742021227_m.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 260px; DISPLAY: block; HEIGHT: 180px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5595403679483109810" border="0" alt="" src="http://2.bp.blogspot.com/-bikFzWOnr6w/TabeADKBIbI/AAAAAAAAFRU/_Y-pST4XZjU/s320/35107_634381195742021227_m.jpg" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;به گزارش خبرنگار پایگاه خبری 125 رخداد این آتش‌سوزی ساعت 6:38 دقیقه بامداد امروز به سامانه 125 اطلاع داده شد و در پی آن ستاد فرماندهی آتش‌نشانی تهران بلافاصله آتش‌نشانان ایستگاه 4 را به محل آتش‌سوزی در خیابان مصطفی خمینی، چهارراه سیروس اعزام کرد.&lt;br /&gt;علیرضا صفی زاده فرمانده آتش‌نشانان در باره این حادثه گفت: آتش‌نشانان با استفاده از تجهیزات ایمنی و خاموش کننده آتش‌سوزی را کاملا خاموش کردند.&lt;br /&gt;وی افزود: بروز اتصالی در سیم‌های برق علت بروز این آتش‌سوزی بوده است.&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5719054815734109328?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5719054815734109328/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5719054815734109328&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5719054815734109328'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5719054815734109328'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/04/blog-post_14.html' title='فروشگاه لوازم منزل در میان شعله‌های آتش ناشی از بروز اتصالی در سیم‌های برق گرفتار و دچار خسارت مالی شد.'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/-bikFzWOnr6w/TabeADKBIbI/AAAAAAAAFRU/_Y-pST4XZjU/s72-c/35107_634381195742021227_m.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6786905621452754781</id><published>2011-04-14T16:00:00.002+04:30</published><updated>2011-04-14T16:06:23.617+04:30</updated><title type='text'>برق آنتن ، صاحبخانه را گرفت</title><content type='html'>&lt;a href="http://3.bp.blogspot.com/-rw3RoLx_lTU/TabcHathONI/AAAAAAAAFRM/lrvsaooxBYg/s1600/electrical%2Bappliances.gif"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 280px; DISPLAY: block; HEIGHT: 232px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5595401607041857746" border="0" alt="" src="http://3.bp.blogspot.com/-rw3RoLx_lTU/TabcHathONI/AAAAAAAAFRM/lrvsaooxBYg/s320/electrical%2Bappliances.gif" /&gt;&lt;/a&gt; ۱۳۹۰ دوشنبه ۲۲ فروردین ساعت 11:51&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;مردی که برای نصب آنتن تلویزیون به پشت بام ساختمان رفته بود دچار برق گرفتگی و روانه بیمارستان شد.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;به گزارش سرویس اجتماعی برنا،رخداد این حادثه را عصر دیروز شهروندان به سامانه 125 اطلاع رسانی کردند و در پی آن ستاد فرماندهی آتش‌نشانی تهران بلافاصله آتش‌نشانان ایستگاه 92 را به محل حادثه در تهرانپارس، خیابان زهدی، خیابان روشن روانه کرد.&lt;br /&gt;&lt;br /&gt;به گفته علیرضا میر فتوحی فرمانده آتش‌نشانان، محل حادثه ساختمان چهار طبقه‌ای بود که مرد 32 ساله ائی روی پشت بام آن دچار برق گرفتگی شده بود.&lt;br /&gt;&lt;br /&gt;وی افزود: آتش‌نشانان با همراه داشتن برانکارد سیار به پشت بام ساختمان رفتند و این شهروند را که در اثر برق گرفتگی آسیب دیده و زخمی شده و دچار خونریزی شده بود پس از انجام کمک‌های اولیه به پائین منتقل کردند و برای مداوا و اعزام به مرکز درمانی در اختیار امدادگران اورژانس قراردادند.&lt;br /&gt;&lt;br /&gt;این فرمانده آتش‌نشانی گفت: در بررسی‌ها مشخص شد این شهروند برای نصب آنتن تلویزیون به پشت بام رفته و در حال انداختن کابل آنتن برای بردن بداخل واحد مسکونی بوده که سیم آنتن بر روی کابل برق می‌افتد و مرد را دچار برق گرفتگی می‌کند.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6786905621452754781?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6786905621452754781/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6786905621452754781&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6786905621452754781'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6786905621452754781'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/04/blog-post.html' title='برق آنتن ، صاحبخانه را گرفت'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-rw3RoLx_lTU/TabcHathONI/AAAAAAAAFRM/lrvsaooxBYg/s72-c/electrical%2Bappliances.gif' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-665120944878876680</id><published>2011-03-14T16:29:00.001+03:30</published><updated>2011-03-14T16:36:50.334+03:30</updated><title type='text'>برگزاری مسابقه اینترنتی ایمنی برق با جوایز نفیس</title><content type='html'>&lt;a href="http://1.bp.blogspot.com/-8XNd67J3Gsc/TX4Sd3C9mOI/AAAAAAAAFQ8/0ug5gVTBb7Q/s1600/pooster%2Bimeny2.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 191px; DISPLAY: block; HEIGHT: 234px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5583920892187875554" border="0" alt="" src="http://1.bp.blogspot.com/-8XNd67J3Gsc/TX4Sd3C9mOI/AAAAAAAAFQ8/0ug5gVTBb7Q/s320/pooster%2Bimeny2.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;شرکت توزیع نیروی برق شهرستان مشهد در پرتال ایمنی و بهداشت خود به منظور اشاعه فرهنگ ایمنی برق در سطح جامعه اقدام به برگزاری مسابقه ایمنی و بهداشت نموده که برای آن جوایز نفیسی در نظر گرفته شده است.&lt;br /&gt;علاقمندان می توانند برای شرکت در مسابقه به آدرس ذیل مراجعه نمایند.&lt;br /&gt;شایان ذکر است برگزاری این مسابقه تداوم خواهد داشت.&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;a href="http://www.iran-eng.com/www.ohsms.meedc.ir" target="_blank"&gt;&lt;span style="font-size:180%;"&gt;WWW.Ohsms.meedc.ir&lt;/span&gt;&lt;/a&gt; &lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-665120944878876680?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/665120944878876680/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=665120944878876680&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/665120944878876680'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/665120944878876680'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/03/blog-post_14.html' title='برگزاری مسابقه اینترنتی ایمنی برق با جوایز نفیس'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/-8XNd67J3Gsc/TX4Sd3C9mOI/AAAAAAAAFQ8/0ug5gVTBb7Q/s72-c/pooster%2Bimeny2.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1361798059270850236</id><published>2011-03-14T16:24:00.005+03:30</published><updated>2011-07-15T14:01:05.919+04:30</updated><title type='text'>چاپ کتابی در زمینه تجهیزات ایمنی برقٍ  Electrical Safety Equipment</title><content type='html'>&lt;div align="right"&gt;نام اين كتاب &lt;b&gt;تجهيزات ايمني برق- فردي و گروهي &lt;/b&gt;مي باشد كه در زمينه تجهيزات مورد استفاده برق كاران و سيمبانان بحث نموده و همچنين بخشي از اين كتاب به ابزارآلات دستي اختصاص داده شده است. مشخصات اين كتاب به شرح ذيل است :&lt;br /&gt;مولف : رضا نيك پيام&lt;br /&gt;ويراستار : محمد علي نورايي&lt;br /&gt;در ۲۲۵ صفحه&lt;br /&gt;تيراژ : ۳۰۰۰ نسخه رنگي&lt;br /&gt;از انتشارات شركت توزيع نيروي برق شهرستان مشهد&lt;br /&gt;در آينده در پرتال ايمني و بهداشت برق مشهد براي علاقمندان نحوه تهيه اين كتاب، اعلام خواهد گرديد.&lt;br /&gt;&lt;a href="http://www.ohsms.meedc.ir/" target="_blank"&gt;http://www.ohsms.meedc.ir/&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 252px; DISPLAY: block; HEIGHT: 320px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5583988976405914930" border="0" alt="" src="http://3.bp.blogspot.com/-9SjQOKVsEuw/TX5QY4hfJTI/AAAAAAAAFRE/6RoTJaLLbsU/s320/asli11.jpg" /&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;span style="color:#0000ff;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="color:#0000ff;"&gt;در اينجا بخشي از پيشگفتار كتاب را كه توسط مديريت محترم عامل شركت توزيع نيروي برق شهرستان مشهد آقاي مهندس سعيدي تهيه و تدوين گرديده،جهت اطلاع شما عزيزان ارائه مي گردد :&lt;/span&gt;&lt;br /&gt;&lt;b&gt;&lt;span style="color:#ff0000;"&gt;« آداب داني» مقدمه ي « ايمني»&lt;/span&gt;&lt;/b&gt;&lt;br /&gt;امروزه « ايمني » به عنوان يك علم و يك رشته ي تخصصي در علوم مختلف مطرح بوده و روش هاي علمي مانند OHSAS 18000 هم براي استقرار و ارزيابي سيستم هاي ايمني در صنايع يا سازمان هايي كه كارشان داراي ابعاد ايمني مي باشد ، مورد اقبال قرارگرفته است.&lt;br /&gt;از نگاه تحليل مسائل ايمني ، وجود تجهيزات مناسب ، ايجاد زمينه هاي ايمني در فرآيند هاي توليد ، شناسايي نقاط خطر و دركنار آن آموزش براي كاركنان وحتي آحاد جامعه امري ضروري است.از طرفي مشاهده مي شود كه تا« فرهنگ ايمني» به عنوان يك « ارزش مثبت» در آحاد جامعه و تمام كاركنان نهادينه نشود ، هرچند تجهيزات مدرن و خوب هم در دسترس باشد متأسفانه از آن استفاده نمي شود و موجب بروز حادثه مي گردد. خيلي از حوادثي كه منجر به جرح يا حتي فوت شده ،وقتي مورد بررسي قرار مي گيرند، مشاهده مي شود كه علي رغم همراه بودن ابزار و تجهيزات ايمني از آن استفاده نشده و درنهايت منجر به بروز آن حادثه ي دردناك شده است.&lt;br /&gt;اينجاست كه متوليان موضوع ايمني درگير بحث هاي فرهنگي مي شوند تا بتواننداز طريق اشاعه ي فرهنگ ايمني ، رعايت اصول،موازين ومقررات ايمني را به عنوان يك ارزش مثبت اجتماعي و فرهنگي جابيندازند.&lt;br /&gt;سئوال اين است كه چگونه « ارزش هاي مثبت فرهنگي» به عنوان معيار جاذبه اي براي امورپسنديده ي جامعه و يا در مقابل آن « ارزش منفي فرهنگي » به عنوان معيار دافعه اي براي امور ناپسند جامعه ايجاد كنيم تا تمام آحاد موردنظر براي اين كه مقبوليت اجتماعي داشته باشند، باالگوبرداري ازآن ارزش گذاري هاي اجتماعي و فرهنگي ،به سمت رعايت مسائل و مقررات ايمني گرايش پيدا نمايند.&lt;br /&gt;بديهي است كه « ارزش» هايي كه تعريف مي شوند، بايد به زبان جامعه باشد تا به راحتي مورد اقبال آنان (اعم از شاغل و غير شاغل) قرار گيرند. يكي از « ارزش» هايي كه درجامعه بسيار مطرح بوده و تمام افراد جامعه سعي مي كنند به گونه اي رفتار نمايند كه متصّف به آن صفت ( ارزش ) باشند، « اخلاق » است . « اخلاق» را چگونه تعريف كنيم تا دايره ي شمول آن به مقررات ايمني برسد؟&lt;br /&gt;بزرگان علم اخلاق ، تعاريف مختلفي از آن داشته اند. ولي «اخلاقي» كه از سوي برخي بزرگان تعريف شده است كارآيي بيشتري دارد و مي تواند دراين رابطه به ما كمك كند .برخي بزرگان گفته اند كه : « اخلاق يعني ادب مقام » .........................................&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1361798059270850236?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1361798059270850236/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1361798059270850236&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1361798059270850236'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1361798059270850236'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/03/blog-post.html' title='چاپ کتابی در زمینه تجهیزات ایمنی برقٍ  Electrical Safety Equipment'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/-9SjQOKVsEuw/TX5QY4hfJTI/AAAAAAAAFRE/6RoTJaLLbsU/s72-c/asli11.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-285819692364375060</id><published>2011-02-01T21:59:00.001+03:30</published><updated>2011-02-01T22:00:58.175+03:30</updated><title type='text'>حادثه دلخراش برق گرفتگی مرد 25 ساله !!</title><content type='html'>&lt;a href="http://www.taknaz.ir/user_files/L128869729838.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 409px; DISPLAY: block; HEIGHT: 299px; CURSOR: hand" border="0" alt="" src="http://www.taknaz.ir/user_files/L128869729838.jpg" /&gt;&lt;/a&gt; این مرد ۲۵ ساله که پدر یک دختر بچه سه ساله است، در مصاحبه‌ای با رسانه‌های دولتی آمریکا، عنوان کرد…&lt;br /&gt;یک مرد اهل ایالت «تگزاس» که صورت خود را به طور کامل بر اثر برق‌گرفتگی از دست داده بود، تحت عمل جراحی موفقیت‌آمیز قرار گرفت.&lt;br /&gt;این مرد که «دالاس سی. وینز» نام دارد، دو سال پیش در پی یک برق گرفتگی شدید دچار سوختگی از ناحیه صورت شده و بینی، چشمان و دهان خود را از دست داد و هم‌اکنون پس از انجام ده‌ها مورد عمل جراحی می‌تواند با دهانش حرف بزند و با بینی‌اش تنفس کند، اما همچنان چشم ندارد.&lt;br /&gt;این مرد ۲۵ ساله که پدر یک دختر بچه سه ساله است، در مصاحبه‌ای با رسانه‌های دولتی آمریکا، عنوان کرد: مخارج عمل جراحی بسیار بالا است، اما من از بیمه پدرم استفاده کردم و در این مدت بارها مورد آزمایشات روانشناسی قرار گرفتم؛ چرا که همسرم مرا رها کرده و در حال جدایی از من است. او شوهر بدون صورت نمی‌خواهد.&lt;br /&gt;این مرد در نوامبر سال ۲۰۰۸ میلادی حین کمک به عمو و برادرش برای نقاشی کردن کلیسای منطقه «فورت وورث» در تگزاس به یکباره کنترل خود را از دست داده و بر روی کابل فشار قوی سقوط کرد.&lt;br /&gt;وی به مدت سه ماه در کما بوده و شش ماه هم برای بهبودی وضعیت سوختگی خود در بیمارستان بستری شد. تمام این مدت هم پیش از این که اهدا کننده عضوی پیدا شود، به جای آن که دهان، دندان، پلک، ابرو و چشم و بینی داشته باشد، پوست جای آن‌ها را گرفته بود.همچنین این مرد ۲۵ ساله با عصای مخصوص نابینایان حرکت می‌کند.&lt;br /&gt;&lt;br /&gt;گردآوری : پایگاه اینترنتی تکناز&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-285819692364375060?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/285819692364375060/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=285819692364375060&amp;isPopup=true' title='1 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/285819692364375060'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/285819692364375060'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/02/25.html' title='حادثه دلخراش برق گرفتگی مرد 25 ساله !!'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4445685237722208590</id><published>2011-01-30T19:10:00.001+03:30</published><updated>2011-01-30T19:12:25.970+03:30</updated><title type='text'>سقوط از بلندی بيشترين دليل مرگ ناشی از حوادث كار</title><content type='html'>&lt;a href="http://www.seemorgh.com/DesktopModules/iContent2/Files/91235.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 300px; DISPLAY: block; HEIGHT: 200px; CURSOR: hand" border="0" alt="" src="http://www.seemorgh.com/DesktopModules/iContent2/Files/91235.jpg" /&gt;&lt;/a&gt;معاون پزشكی و آزمايشگاهی سازمان پزشكی قانونی كشور گفت: سقوط از بلندی 3/36 درصد از آمار حوادث ناشی از كار را در سال گذشته شامل می شود كه اين عامل بيش از ساير موارد موجب مرگ افراد در حين كار شده است...&lt;br /&gt;به گزارش روز یكشنبه اداره كل روابط عمومی و امور بین‌الملل سازمان پزشكی قانونی كشور 'عبدالرزاق برزگر' افزود:در سال گذشته یك هزار و 224 نفر بر اثر حوادث ناشی از كار جان خود را از دست دادند كه از این تعداد 444 نفر بر اثر سقوط از بلندی، 332 نفر (1/27 درصد) بخاطر برخورد جسم سخت و 143 نفر(7/11درصد) بدلیل برق‌ گرفتگی فوت كردند.&lt;br /&gt;وی ادامه داد:از كل فوت شدگان ناشی از حوادث كار در سال گذشته، 6/4 درصد بر اثر سوختگی و 3/20 درصد نیز به دلیل سایر علل جان خود را از دست داده اند.&lt;br /&gt;بزرگر به سیر صعودی مرگ و میر حوادث ناشی از كار در سال های 1381 تا 1387 اشاره كرد و گفت :مرگ ناشی از حوادث كار در سال 87 در مقایسه با سال قبل از آن 4/64 درصد افزایش یافته است.&lt;br /&gt;معاون پزشكی و آزمایشگاهی سازمان پزشكی قانونی كشور با بیان این كه مرگ و میر حوادث ناشی از كار در سال 88 نسبت به سال قبل از آن 4/7 درصد كاهش یافت، افزود: این میزان از هزار و 481 نفر در سال 87 به هزار و 224 نفر در سال 88 رسیده است.&lt;br /&gt;برزگر با اشاره به این كه در9 ماهه ابتدای امسال 993 نفر بر اثر حوادث ناشی از كار جان خود را از دست دادند،گفت : در مدت مشابه سال گذشته 951 نفر در این حوادث فوت كردند.&lt;br /&gt;منبع:irna.ir&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4445685237722208590?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4445685237722208590/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4445685237722208590&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4445685237722208590'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4445685237722208590'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_6620.html' title='سقوط از بلندی بيشترين دليل مرگ ناشی از حوادث كار'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8974631521804617217</id><published>2011-01-30T19:07:00.000+03:30</published><updated>2011-01-30T19:09:54.974+03:30</updated><title type='text'>برق گرفتگی یک نوجوان در ايستگاه اتوبوس در قلهک</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;span style="font-size:130%;"&gt;پسر نوجوان كه در ايستگاه اتوبوس شهری دچار برق گرفتگی شده همچنان در حالت «كما» با مرگ دست و پنجه نرم می‌كند و پزشكان وضعيت او را وخيم اعلام كرده‌اند....&lt;br /&gt;پسر نوجوان كه در ایستگاه اتوبوس شهری دچار برق گرفتگی شده همچنان در حالت «كما» با مرگ دست و پنجه نرم می‌كند و پزشكان وضعیت او را وخیم اعلام كرده‌اند.&lt;br /&gt;&lt;br /&gt;این در حالی است كه به گفته اهالی محل تاكنون چند تن دیگر از شهروندان در همین ایستگاه دچار برق گرفتگی و حادثه شده بودند. یوسف اسلامی پدر علیرضا – 16 ساله – درباره این حادثه هولناك گفت: عصر یكشنبه 26 دی پسرم به دنبال خروج از آموزشگاه زبان حوالی محله قلهك به سوی خانه در حركت بود كه ناگهان هنگام عبور از كنار ایستگاه اتوبوس روبه‌روی بیمارستان ایرانمهر – در خیابان شریعتی – بر اثر برق گرفتگی شدید دچار تشنج شد و نیمه جان روی زمین افتاد.&lt;br /&gt;&lt;br /&gt;همان موقع شاهدان با مشاهده این صحنه دلخراش بلافاصله پیكر پسرم را به بیمارستان ایرانمهر منتقل كردند. پزشكان نیز پس از معاینات لازم اعلام كردند علیرضا به خاطر شدت مصدومیت به كما رفته است.&lt;br /&gt;&lt;br /&gt;بنابراین بلافاصله پسرم را در بخش مراقبت‌های ویژه بستری كردند. پدر نوجوان مصدوم در ادامه گفت: در حال حاضر شكایتی علیه شهرداری منطقه و مسئولان مربوطه از جمله اداره برق مطرح كرده‌ام‌. پرونده نیز از سوی دادیار دادسرای ونك در حال رسیدگی است. وی افزود: بعد از این حادثه دلخراش چندین بار با شهرداری تماس گرفتم و موضوع را با آنها در میان گذاشتم.&lt;br /&gt;&lt;br /&gt;اما تاكنون هیچ پاسخی نشنیده‌ام. این در حالی است كه شرایط جسمی پسرم بشدت وخیم است و نمی‌دانم مسئولان شهرداری چرا تاكنون به این موضوع توجهی نكرده‌اند. یكی از شاهدان حادثه كه پسر مصدوم را به بیمارستان منتقل كرده بود نیز به خبرنگار ما گفت: این ایستگاه حدود یك سال قبل راه‌اندازی شده است. حال آنكه پیمانكار برای روشن كردن لامپ‌های داخل ایستگاه سیم‌كشی غیرمجاز كرده است.&lt;br /&gt;&lt;br /&gt;بنابراین در مواقع بارندگی شاهد اتصالی سیم‌ها و بروز حادثه برای رهگذران یا مسافران اتوبوس هستیم. البته بارها این موضوع را به مسئولان شهرداری اعلام كرده‌ایم. متأسفانه تاكنون هیچ كس به این موضوع كه با جان مردم سر و كار دارد توجهی نكرده بود تا اینكه پس از بروز حادثه دلخراش برای پسر نوجوان رهگذر مسئولان شهرداری و اداره برق رسیدگی به موضوع را در دستور كار قرار دادند. گفتنی است پزشكان حال علیرضا را بشدت وخیم اعلام كرده‌اند. با این وجود تلاش تیم پزشكی برای نجات جانش همچنان ادامه دارد.&lt;br /&gt;&lt;/span&gt;منبع:tabnak.ir&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8974631521804617217?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8974631521804617217/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8974631521804617217&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8974631521804617217'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8974631521804617217'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_528.html' title='برق گرفتگی یک نوجوان در ايستگاه اتوبوس در قلهک'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2791231791879326734</id><published>2011-01-30T07:15:00.000+03:30</published><updated>2011-01-30T07:16:33.206+03:30</updated><title type='text'>داستان مديريتي تد</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;گفته ميشود ،روزي مرد ثروتمندي سگ باوفاي خود را بنام تد (TED)براي شکار گراز به آفريقا ميبرد. يکروز که هردو شاد و سرحال براي شکار وارد جنگل هاي انبوه شده بودند، توجه تد به يک پروانه زيبا مي افتد و تد هم براي سرگرمي به تعقيب آن ميره و از اين ور به آنور بدنبال پروانه مي جهد تا اينکه متوجه ميشود گم شده . دست بر قضا پي ميبرد که يک پلنگ تيزپا براي خوردن او به سرعت هرچه تمام به سمتش مي دود. تد متوجه ميشود که در بد مخمصه اي افتاده و راه گريزي هم ندارد و هرلحظه نيز پلنگ گرسنه به او نزديک و نزديکتر ميشه. بنظرش مي آيد که پا بفرار بگذاره اما فورا متوجه ميشه که فرار از دست پلنگ يعني صدور مجوز خورده شدن . بلافاصله بفکر مي افته و ذهن و چشمان تيزبين اش را به اطراف ميچرخاند تااينکه در آن اطراف يکسري استخوان از لاشه حيوانات مرده را ميبينه . تد فورا مشغول ليسيدن استخوانه ميشه و وقتي ميبينه پلنگ به چند قدمي اش رسيده با صداي بلند ميگه عجب شير خوشمزه اي بود.....!!!!! \"به به\".&lt;br /&gt;پلنگ گرسنه با شنيدن اين حرف آب تو دهانش خشک ميشه و فورا عقب گرد ميکنه و پا ميگذاره به فرار . و به خودش ميگه داشتم عجب اشتباهي مي کردم.&lt;br /&gt;دست بر قضا يک ميمون فضول بالاي درخت در همان نزديکي نظاره گر صحنه بوده و وقايع را ميبينه . ميمون براي خود شيريني و براي اينکه ار دست گزند پلنگ در روزهاي آتي در امان باشه فورا ميره طرف پلنگ و داستان را برايش تعريف ميکنه و به پلنگ ميگه دچار چه اشتباهي شده بوده . پلنگ از شنيدن اين حرف و نتيجه گيري خودش بسيار خشمگين و ناراحت ميشه و با عصبانيت و گرسنگي مضاعف با ميمون مجددا به سمت سگ بخت برگشته حمله ور ميشه.&lt;br /&gt;تد بيچاره که دلش خوش بود از چنگ پلنگ رها شده مجددا خودش را درکام مرگ ميبينه و پي ميبره که پلنگ اينبار مغضوبانه به سمت او حمله ور شده و ميمون هم در مصاف با او همراه است . کم مانده بود که تد از ترس قالب تهي کنه اما فورا به خودش مي ياد و بفکر يک چاره مي افته.&lt;br /&gt;بنظر شما عکس العمل تد اين بار چي بايد باشه که باز هم بتونه از کام مرگ رهانده بشه ...!!!!؟؟؟؟&lt;br /&gt;تد مجددا خودش را مشغول خوردن باقيمانده استخوانها نشان ميده و ميگذاره تا پلنگ و ميمون بهش نزديک تر شوند بعد که از نزديکي آنها مطمئن ميشه با صداي بلند ميگه اين ميمون احمق رفت براي من يک پلنگ بياره که بخورم ولي فکر ميکنم که از پس اش بر نياد. پلنگ عصبي و گرسنه با شنيدن اين جمله درجا مي ايسته و فکر ميکنه که عجب رودستي خورده و اگر جلوترازاين بره حتما در تله افتاده به همين خاطر عقب گرد ميکنه وپا بفرار ميگذاره و ميمون چاپلوس هم بدنبال پلنگ ميره که سگه داره دروغ ميگه . به محض اينکه پلنگ متوجه ميشه که از تد فاصله گرفته در يک حرکت تهاجمي ميمون را با چنگالهايش خفه ميکند و او را به بالاي اولين درخت ميبره و نوش جان ميکنه.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;نتيجه گيري:&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;براي يک مدير وقايع و حوادثي نا خوشايند و غير مترقبه حادث ميشود و بالطبع يک مدير براي تثبيت موقعيت خود و سازمانش مجبور به اتخاذ تصميم بموقع و بجا دارد. قطعا آنچه نقطه انحطاط و سقوط يک سازمان ميشود،خود مشکل نيست بلکه ترس و نگراني مديرمهمترين عاملي است که باعث چشم برداشتن وي از هدف و رفتن به بيراهه ميباشد.&lt;br /&gt;يک مدير طي مدت مديريتش بارها و بارها با چنين تهديداتي روبرو ميشه و نقش يک پلنگ را عوامل متعددي از جمله رقباي کوته بين ويا تصميمات فوري يک انجمن صنفي و يا سياست گذاري هاي دولت تعيين ميکند، که هريک از آنها ميتواند تهديدات بالقوه ويا بالفعلي باشد که يک سازمان و کارمندانش را به ورطه نابودي ميکشد. در اينجا نقش يک مدير و تصميماتش بسيار حساس و حياتي ميباشد . و مهمترين نکته آن است که خونسردي و آرامش را هرگز نبايد از ياد برد.&lt;br /&gt;به خاطرداشته باشيد ، مهم اين نيست که يک مدير چه نوع مشکلاتي برايش حادث ميشود مهم آن است که او با چه مهارتي ميتواند مسائل را تحليل کند و بهترين راه حل را اتخاذ کند.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2791231791879326734?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2791231791879326734/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2791231791879326734&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2791231791879326734'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2791231791879326734'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_30.html' title='داستان مديريتي تد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7373336038617095080</id><published>2011-01-24T17:15:00.003+03:30</published><updated>2011-01-24T17:19:53.201+03:30</updated><title type='text'>عرضه یک لامپ خورشیدی جدید برای کاهش هزینه قبض برق</title><content type='html'>&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 389px; DISPLAY: block; HEIGHT: 236px; CURSOR: hand" border="0" alt="" src="http://www.mehrnews.com/mehr_media/image/2010/12/600013_orig.jpg" /&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;یک شرکت هنگ کنگی لامپ جدیدی را عرضه کرده است که با انرژی خورشیدی می تواند حداکثر تا 6 ساعت روشنایی داده و تا حد چشمگیری در هزینه برق صرفه جویی کند.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;به گزارش سرویس علم و فن آوری پایگاه اطلاع رسانی صبا به نقل از خبرگزاری مهر، چراغهایی که در خانه و اداره روشنایی محیط را تامین می کنند علاوه بر اینکه همه ساله حجم بسیار بالایی دی اکسید کربن را در اتمسفر رها می کند موجب افزایش قیمت قبض برق می شود.&lt;br /&gt;در این راستا شرکت هنگ کنگی Nokero نوعی لامپ جدید را به نام "ان. 200" عرضه کرده است که می تواند هم در کاهش هزینه ها و هم کمک به محیط زیست بسیار موثر باشد.&lt;br /&gt;این لامپ ویژه با انرژی خورشیدی عمل می کند. در این لامپ، یک پانل یکپارچه بر روی لامپ نور خورشید را جمع آوری کرده و یک باتری NiMh را شارژ می کند.&lt;br /&gt;این باتری می تواند انرژی لازم برای نور چهار لامپ کوچک "ال. ای. دی" را که داخل حباب اصلی قرار گرفته اند بین 5/2 تا 6 ساعت تامین کند.&lt;br /&gt;بر اساس گزارش دیوایس، "ان. 200" دارای یک قاب ضد آب است و بنابراین می تواند روشنایی محیط بیرون را هم تامین کند.&lt;br /&gt;نسبت به نسخه قبلی این محصول "نوکرو"، این لامپ خورشیدی 60 درصد نور بیشتری تولید می کند.&lt;br /&gt;پانل خورشیدی این لامپ از قابلیت چرخش و تغییر جهت دادن به سمت منبع انرژی خورشید را دارد. این لامپ به قیمت 20 دلار در روی سایت تولیدکننده به فروش می رسد.&lt;br /&gt;"ان. 200" یک منبع روشنایی کاربردی برای مناطقی است که از برق شهری برخوردار نیستند. &lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 377px; DISPLAY: block; HEIGHT: 236px; CURSOR: hand" border="0" alt="" src="http://www.mehrnews.com/mehr_media/image/2010/12/600014_orig.jpg" /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7373336038617095080?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7373336038617095080/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7373336038617095080&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7373336038617095080'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7373336038617095080'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/6.html' title='عرضه یک لامپ خورشیدی جدید برای کاهش هزینه قبض برق'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3997084757796303367</id><published>2011-01-24T17:06:00.001+03:30</published><updated>2011-01-24T17:09:08.508+03:30</updated><title type='text'>با نحوه محاسبه هزینه برق خانگی آشنا شویم</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;p&gt;&lt;strong&gt;&lt;span style="color:#33cc00;"&gt;همزمان با اجرای قانون هدفمندی یارانه‌ها و آغاز اصلاح قیمت‌ها در کشور،‌ ‌متوسط نرخ مصوب تعرفه‌های جدید برق 450 ریال تعیین شده و در این راستا ضروری است تمام مشترکین از نحوه محاسبه قبوض برق خود مطلع شوند.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;به گزارش پایگاه اطلاع رسانی صبا به نقل از ایرنا، ‌متوسط نرخ مصوب تعرفه های برق در بخش خانگی در مناطق گرمسیر 140 ریال است و الگوی کنونی محاسبه نرخ برق در فصل تابستان در چهار منطقه گرمسیر کشور همچنان پابرجا خواهد بود.&lt;br /&gt;همچنین حداکثر بهای انرژی بدون احتساب اضافه پرداختی ساعات اوج بار و کاهش هزینه ساعات کم باری به ازای هر کیلووات ساعت بطور متوسط 1300 ریال در نظر گرفته شده است.&lt;br /&gt;نرخ خانگی عادی برق پیش از اجرای هدفمندی یارانه‌ها به صورت پیچیده‌ای محاسبه می‌شد اما پس از اجرای قانون کتابچه قطور تعرفه‌های برق و شرایط عمومی آن بسیار ساده، شفاف و یکسان شده و افراد حتی با کمترین سواد نیز می‌توانند میزان صورتحساب خود را محاسبه کنند. همچنین نحوه محاسبه صورتحساب در قبوض برق ذکر شده است.&lt;br /&gt;براساس قیمت‌های جدید برق مصرف صفر تا 100 کیلووات ساعت برق در ماه هر واحد 270ریال، مازاد بر 100 تا 200 کیلووات ساعت هر واحد 320 ریال، مازاد بر 200 تا 300 کیلووات ساعت هر واحد 720 ریال، مازاد بر 300 تا 400 کیلووات ساعت هر واحد یکهزار و 300 ریال،‌ مازاد بر 400 تا 500 کیلووات ساعت هر واحد یکهزار و 500 ریال، مازاد بر 500 تا 600 کیلووات ساعت هر واحد یکهزار و 900 ریال و مازاد بر 600 کیلووات ساعت هر واحد دو هزار و 100 ریال محاسبه می‌شود.&lt;br /&gt;بعنوان مثال در صورتی که یک مشترک خانگی در ماه 375 کیلو وات مصرف داشته باشد مبلغ قبض اینگونه محاسبه می شود: 228500=100x270+100 x320+100 x720+75x1300&lt;br /&gt;‌در صورتی که مشترک فوق تنها 20 درصد(75 کیلو وات ساعت)مصرف خود را کاهش دهد مبلغ صورتحساب فوق به میزان 40 درصد کاهش می یابد و بصورت زیر محاسبه می شود:&lt;br /&gt;131000=100x270+100 x320+100 x 720&lt;br /&gt;قیمت‌های جدید از روز آغاز اجرای قانون هدفمندی یارانه‌ها(یکشنبه 28 آذر ماه)در قبوض مشترکان اعمال می‌شود و آبونمان نیز از قبوض برق حذف شده و تنها چیزی که اضافه می‌شود 3 درصد مالیات بر ارزش افزوده است.&lt;br /&gt;همچنین بهای برق مصرفی مشترکین خانگی در مناطق فاقد شبکه گازرسانی در استان های هرمزگان، بوشهر و خوزستان برای سه ماه دی، بهمن و اسفند با ضریب 0.6 نسبت به نرخ تعرفه خانگی محاسبه و دریافت می شود.&lt;br /&gt;تا دهک ششم مصرف، اختلاف صورتحساب جدید برق حداکثر 36 هزار ریال است و دهک هفتم مصرف نیز در صورت 10درصد صرفه‌جویی تنها چهار هزار تومان در ماه با افزایش مبلغ صورتحساب مواجه خواهد شد.&lt;br /&gt;دهک‌های هشتم و نهم نیز با اختلافی در حدود 80 و 110 هزار ریال مواجه خواهند شد اما دهک دهم مصرف باید مدیریت مصرف انجام دهد و صرفه‌جویی کند.&lt;br /&gt;‌ در مورد 60 درصد مشترکین مبلغ صورتحساب ماهیانه تنها 350 هزار ریال افزایش خواهد یافت و این در حالی است که مشترکین بخش خانگی تنها با 10 درصد صرفه‌جویی می‌توانند 20 تا 30 درصد از هزینه صورتحساب خود را کاهش دهند.&lt;br /&gt;همچنین هزینه برق مصرفی 70 درصد مشترکین خانگی با مصرف ماهانه 225 کیلووات ساعت کمتر از 77000 ریال است، چرا که: ریال 77000=100x270+100 x320+25 x 720&lt;br /&gt;از سوی دیگر باید توجه داشت هزینه برق مصرفی مشترکین با کنتورهای یک زمانه فقط به صورت میانباری محاسبه شده و مشمول هزینه اوج مصرف و تخفیف کم‌باری نمی شود.&lt;br /&gt;نرخ‌های جدید برق تا اطلاع ثانوی پابرجا خواهد بود و بنظر نمی‌آید که در سال آینده تغییری در آنها ایجاد شود و این در حالی است که با توجه به تعرفه‌های جدید برق دولت همچنان بیش از 55 درصد به مردم بابت برق مصرفی شان یارانه می‌دهد.&lt;br /&gt;هم اکنون کشورمان از لحاظ میانگین مصرف در سطح بالایی قرار دارد و این در حالی است که در صورت صرفه‌جویی 30 درصدی در مصرف برق هیچ مشکلی در سطح رفاه و تولید کشور بوجود نمی‌آید.&lt;br /&gt;همچنین بیش از 74 درصد از مجموع مشترکان برق صورتحساب ‌های خود را بصورت ماهیانه&lt;br /&gt;دریافت می‌کنند(شامل بخش‌های عمومی، صنعتی و دیماندی)و در نظر است تا با برنامه‌ریزی صورتحساب تمام مشترکان برق کشور بصورت ماهیانه صادر شود‌.&lt;br /&gt;با قیمت‌های جدید برق تنها 45 درصد هدفمندی یارانه‌ها در بخش برق اجرایی شده و همچنان 55 درصد یارانه به بخش برق پرداخت می‌شود.&lt;br /&gt;براساس تاکید مسوولان وزارت نیرو محتویات بسته برق طرح تحول اقتصادی در جلسات متعددی با حضور کارشناسان و مسوولان دولتی و 14 جلسه نیز با حضور رییس جمهور مورد کارشناسی قرار گرفته است.&lt;br /&gt;&lt;/p&gt;ایرنا&lt;br /&gt;۳ بهمن ۱۳۸۹ ۲۰:۱۰&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3997084757796303367?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3997084757796303367/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3997084757796303367&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3997084757796303367'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3997084757796303367'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_24.html' title='با نحوه محاسبه هزینه برق خانگی آشنا شویم'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6072704586651266339</id><published>2011-01-23T09:00:00.000+03:30</published><updated>2011-01-23T09:04:04.182+03:30</updated><title type='text'>Why Perception Surveys are Not Enough</title><content type='html'>&lt;div dir="ltr" align="left"&gt;By: Terry L. Mathis&lt;br /&gt;There is a basic flaw in the way companies often measure and manage safety cultures.&lt;br /&gt;Several years ago, I attended a meeting at the invitation of a major petrochemical company. I had known the spokesman for the organization for many years and worked with him on several occasions. He presented his problem to me in very personal terms: “Terry, a recent survey indicates that our workers don't think our managers are serious about safety. If we hire you to help fix this problem, what will be your first step?”&lt;br /&gt;I responded that my first step would be to find out if the perception was accurate or not. The group looked a bit shocked and asked if I was suggesting that it was accurate. I explained that the scope of the issue depended on the accuracy or inaccuracy of the perception. If the perception was inaccurate, I would only need to fix the perception. If the perception was accurate, there would almost surely be a larger problem to solve.&lt;br /&gt;This story illustrates a basic flaw in the way we often measure and manage safety cultures. Perceptions can be inaccurate. Organizations that measure perceptions and react to their findings, without further information, may be chasing a specter. Perceptions alone are ungrounded metrics without a proper frame of reference, from which appropriate actions can be determined. Measuring perceptions only determines if those polled have a perception and if the perceptions of the group are similar or dissimilar.&lt;br /&gt;PROBLEMS WITH PERCEPTIONS&lt;br /&gt;Some try to ground perception metrics by comparing them to the perceptions of others who have taken the same survey. This only serves to give a comparative score to the organizational or site metric in relation to the rest of the group of those polled. Often the group has no real definition. It is simply “everyone who has taken this survey.” You still don't know if the group represents safety excellence, mediocrity or totally poor performance.&lt;br /&gt;How, exactly, do you respond to this placement information? Will improving your perception placement score from 40 percent to 70 percent translate into improved safety performance? Should any 40 percent score take priority over any higher score? Does a variation in perceptions across sites or departments represent a difference in practice or simply a difference in perception of performance? An old axiom of comparative metrics is that 49 percent of every group is below average.&lt;br /&gt;To understand the limitation of this type of metric, imagine a group of people in a lifeboat at sea on a cloudy day. There are no landmarks in sight and no one can see the sun, moon or stars. Someone in the boat shouts out, “Which way is north?”&lt;br /&gt;The response of those in the boat will provide a certain type of information. You will find out if anyone thinks they know which way is north. You also will find out what percent of the group agrees or disagrees. What you don't know from this “perception survey” is whether any or all of the groups' perceptions are correct.&lt;br /&gt;Another problem with measuring perceptions is the volatility of what you are measuring. Perceptions drastically can be changed by events and the flow of information. Ask everyone if they think this is a safe place to work right after you have announced layoffs.&lt;br /&gt;Fail to publish or utilize the results of the last perception survey and see what kind of barrier you have created when you administer the next one. Measure too often or too seldom and you will impact answers. One site I worked with recently had their perceptions audited so often they had become numb to the process. I referred to their condition as “auditism.”&lt;br /&gt;These problems do not mean that perceptions should not be measured or that such measures are hopelessly flawed. It simply means that you need more information to put the perceptions into a manageable context. I call this process “grounding” the metrics.&lt;br /&gt;Grounded metrics are multiple metrics that give each other context. For example, do perceptions of risk match accident data on which risk most often results in accidents? These kinds of data sets put each other in the proper context to understand if the perceptions are accurate or inaccurate.&lt;br /&gt;COMMUNICATION&lt;br /&gt;I have been asked to solve numerous problems that were simple issues of miscommunication or lack of formal communication. Perceptions especially are vulnerable to communication or the lack of communication. Therefore, it is critical that all perception surveys have an “uncertain” response and that percent uncertain be calculated. A high percent uncertain on any perception potentially can indicate a lack of communication on that issue.&lt;br /&gt;A Harvard Business School researcher recently conducted a study in which he asked managers how often they communicated on the subject of safety. Managers at the site being studied rated themselves high in their level of communication on safety.&lt;br /&gt;The researcher then asked managers to keep a log of communication on safety for 90 days in which they recorded the number of times they talked to subordinates and the number of times their communication included the topic of safety. After the study, managers lowered their self ratings by over 60 percent. Many organizations do not view communications as a means of managing perceptions; but it often is. Perceptions that are not managed will vary depending on individual experience and levels of communication. The management of perceptions may be the new frontier of safety cultural management.&lt;br /&gt;One of the leading edges of safety culture management is the merging of safety metrics into something resembling the strategic management model of the balanced scorecard. Strategic managers realized the limitations of lagging indicators and started exploring the alternatives under the tutelage of Kaplin and Norton. They developed three other groupings of metrics that centered on the organizational mission statement and helped managers to see the reality of the business (what Deming called “profound knowledge”) and manage more efficiently.&lt;br /&gt;Several companies and organizations are engaged in similar efforts in safety and have some interesting commonalities. Safety, like strategic or economic management, has lagging indicators. We normally measure recordable rates, severity rates, costs of leading safety-related expenses, etc. Additionally, these organizations are measuring safety processes such as training, meetings, new-employee orientations, etc., to see if they are going according to plan.&lt;br /&gt;The second metric is perceptions: Are these efforts affecting how workers think about safety? The third metric is behaviors: Do these efforts and resulting changes in perceptions impact what people do in the workplace (common practice)? These three impact the fourth, which is results, or lagging indicators. This multiple metric for safety has turned into a digital dashboard for many organizations. The final step will be to develop the algorithms that explain how these multiple metrics impact each other.&lt;br /&gt;It may be possible in the near future to measure how a new training program impacts perceptions, which impacts behaviors, which impacts accident rates. It one day may be possible to predict in advance these results and the return on investment of such projects. Until then, we must realize the limitations of perception surveys and strive to ground them in the realities of the safety culture to better understand how such data can be used effectively to improve the cultures we are trying to measure. &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6072704586651266339?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6072704586651266339/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6072704586651266339&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6072704586651266339'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6072704586651266339'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/why-perception-surveys-are-not-enough.html' title='Why Perception Surveys are Not Enough'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3547791052796245917</id><published>2011-01-21T15:53:00.003+03:30</published><updated>2011-01-21T15:59:09.538+03:30</updated><title type='text'>جملات کوتاه</title><content type='html'>&lt;span style="font-size:130%;"&gt;بهبود، رشد و تعالي ميسر است تنها اگر باور هاي خود را به چالش کشيده و نگرش هاي خود را مديريت نماييم.&lt;br /&gt;&lt;br /&gt;رفتارهاي مشابه، نتايج مشابهي دارند، براي مشاهده نتايج متفاوت همين الان شروع به تغيير نماييد.&lt;br /&gt;&lt;br /&gt;بزرگ فکر کن، کوچک عمل کن، همين الان شروع کن. (حضرت علي (ع))&lt;br /&gt;&lt;br /&gt;نيچه فيلسوف مشهور معتقد است: « آنکه چرايي براي زيستن دارد، هر چگونه اي را تحمل خواهد کرد ».&lt;br /&gt;پس از سالها مشاوره به مديران در سازمانها و شرکتهاي مختلف فکر مي کنم نيازي به تحمل چگونه ها نيست بلکه « آنان که چرايي دارند، چگونه را مي يابند »&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3547791052796245917?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3547791052796245917/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3547791052796245917&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3547791052796245917'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3547791052796245917'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_6051.html' title='جملات کوتاه'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-641026562051996185</id><published>2011-01-21T15:26:00.000+03:30</published><updated>2011-01-21T15:27:51.898+03:30</updated><title type='text'>منفعت مردن</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;روزي خوکي نزد گاو ماده مزرعه مي رود و با اندوه و ياس فراوان به گاو مي گويد :\\"ميتونم يک سوالي را ازت بپرسم ، اما خواهش ميکنم که رک و بي پرده پاسخم را بده . بهت قول ميدهم که از پاسخت ناراحت نشم .\\"&lt;br /&gt;گاو با کمال حيرت مي گويد : خوب بپرس .&lt;br /&gt;خوک : گرچه ميدانم که تو فقط به اهالي روستا شير ميدهي ولي مردم از گوشت تازه و پرچرب من همبرگر و سوسيس و کالباس درست ميکنند و خيلي هم لذت ميبرند . اما با اين وجود هيچکس از من تعريفي نمي کند و کسي مرا دوست ندارد. در عوض تورا همه دوست دارند. بهترين چراگاه ها و علوفه هاي تازه براي تو فراهم است اما من بايد تفاله و آشغالها را بخورم . دليل اين کم لطفي از طرف مردم چيست ؟&lt;br /&gt;گاو با لبخندي پاسخ داد: علت علاقه مردم به من در آن است که من در حاليکه زنده ام نفعم به مردم ميرسد و نفع تو بعد از مرگت به مردم ميرسه.&lt;br /&gt;نتيجه گيري:&lt;br /&gt;بيائيد به گونه اي زندگي کنيم که ديگران وجودمان را احساس کنند.&lt;br /&gt;خير رساندن و شاد کردن مردم را مي بايد در وجودمان پرورش دهيم.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-641026562051996185?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/641026562051996185/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=641026562051996185&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/641026562051996185'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/641026562051996185'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_21.html' title='منفعت مردن'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1301858834365073407</id><published>2011-01-10T13:28:00.000+03:30</published><updated>2011-01-10T13:29:02.340+03:30</updated><title type='text'>علائم اخطارهاي خاص P.SPEIAL WARNING</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;span style="font-size:130%;"&gt;P50 مواد محتوي سرب ، نبايستي بر روي سطوحي زده شود كه در معرض جويدن و يا مكيدن بچه ها قرار ميگيرد .&lt;br /&gt;PS51 تنفس نمودن ،‌ تماس با پوست و چشمها و يا بلع اين ماده مضر و محرك و سوزش آور است .&lt;br /&gt;PS52‌ در صورت تماس با چشمها يا پوست ، محل را فورا" با آب زياد بشوئيد و بدقت به دستورات پزشك عمل نمائيد .&lt;br /&gt;P53 مواد محتوي ايزو سيانات ها است در اين مورد توصيه هاي ايمني خاصي توسط توليد كننده ارائه ميگردد كه ميبايستي بدقت رعايت شوند . &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1301858834365073407?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1301858834365073407/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1301858834365073407&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1301858834365073407'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1301858834365073407'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/pspeial-warning.html' title='علائم اخطارهاي خاص P.SPEIAL WARNING'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5848629110972031163</id><published>2011-01-10T13:24:00.000+03:30</published><updated>2011-01-10T13:25:30.571+03:30</updated><title type='text'>تفسير كدهاي ايمني طبق استاندارد</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;عوامل خطر&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;R1 = در صورت خشك شدن منفجر و يا قابل انفجار ميگردد .&lt;br /&gt;R2 = خطر انفجار بر اثر ضربه ، اصطكاك و تماس با آتش و ديگر منابع جرقه زا وجود دارد .&lt;br /&gt;R3 = فوق العاده خطر انفجار بر اثر ضربه ، اصطكاك و تماس با آتش و ديگر منابع جرقه زا وجود دارد.&lt;br /&gt;R4 = تركيبات فلزي (‌ Metalic ) قابل انفجار بسيار حساسي را شكل ميدهد .&lt;br /&gt;R5 = گرم كردن آن سبب بروز انفجار ميشود .&lt;br /&gt;R6 = در حضور يا در غياب هوا قابليت انفجار دارد .&lt;br /&gt;R7 = احتمال بروز آتش سوزي وجود دارد .&lt;br /&gt;R8 = در صورت تماس با مواد قابل اشتعال ، خطر بروز آتش سوزي وجود دارد .&lt;br /&gt;R9 = در صورت اختلاط با مواد قابل اشتعال منفجر و يا قابل انفجار ميگردد .&lt;br /&gt;R10 = قابل اشتعال است .&lt;br /&gt;R11 = بسهولت قابل اشتعال است .&lt;br /&gt;R12 = فوق العاده قابل اشتعال است .&lt;br /&gt;R13 = گاز مايع ، فوق العاده قابل اشتعال است .&lt;br /&gt;R14 = با آب بشدت واكنش نشان ميدهد .&lt;br /&gt;R15 = در تماس با آب ، گازهاي قابل اشتعال زيادي را آزاد مي نمايد .&lt;br /&gt;R15-1 = در تماس با اسيدها ، گازهاي قابل اشتعال زيادي را آزاد مي نمايد .&lt;br /&gt;R16 = در صورت تركيب با مواد اكسيداسيون منفجر و يا قابل اشتعال ميگردد .&lt;br /&gt;R17 = در مجاورت هوا خود به خود قابل اشتعال ميگردد .&lt;br /&gt;R18 = احتمال تشكيل مخلوطي از بخار و هواي قابل انفجار يا اشتعال در موقع مصرف وجود دارد .&lt;br /&gt;R19 = ممكن است پراكسيدهاي قابل انفجار تشكيل گردد .&lt;br /&gt;R20 = استنشاق آن براي سلامتي زيان آور است .&lt;br /&gt;R21 = تماس آن با پوست زيان آور است .&lt;br /&gt;R22 = خوردن آن زيان آور است .&lt;br /&gt;R23 = استنشاق آن مسموميت ايجاد ميكند .&lt;br /&gt;R24 = تماس آن با پوست مسموميت ايجاد ميكند .&lt;br /&gt;R25 = خوردن آن مسموميت ايجاد ميكند .&lt;br /&gt;R26 = استنشاق آن مسموعيت شديد ايجاد ميكند .&lt;br /&gt;R27 = تماس آن با پوست مسموعيت شديد ايجاد ميكند .&lt;br /&gt;R28 = خوردن آن مسموعيت شديد ايجاد ميكند .&lt;br /&gt;R29 = تماس آن با آب ، گاز سمي متصاعد ميكند .&lt;br /&gt;R30 = در موقع مصرف ممكن است شديدا" قابل اشتعال شود .&lt;br /&gt;R31 = تماس آن با اسيدها ، گازهاي سمي آزاد ميكند .&lt;br /&gt;R31-1 = تماس آن با قلياها ، گازهاي سمي آزاد ميكند .&lt;br /&gt;R32 = تماس آن با اسيدها ، گازهاي شديدا" سمي آزاد ميكند .&lt;br /&gt;R33 = خطر عوارض جانبي براي سلامتي دارد .&lt;br /&gt;R34 = سبب سوختگي ميشود .&lt;br /&gt;R35 = سبب سوختگي شديد ميشود .&lt;br /&gt;R36 = سبب سوزش يا تحريك سيستم تنفسي ميشود .&lt;br /&gt;R37 = سبب سوزش يا تحريك سيستم تنفسي ميشود .&lt;br /&gt;R38 = سبب سوزش يا تحريك پوست ميشود .&lt;br /&gt;R39 = خطر جدي بروز صدمات علاج ناپذير وجود دارد .&lt;br /&gt;R40 = احتمال بروز صدمات علاج ناپذير وجود دارد .&lt;br /&gt;R41 = خطر صدمه به چشم ها وجود دارد .&lt;br /&gt;R42 = احتمال بروز حساسيت از طريق استنشاق وجود دارد .&lt;br /&gt;R43 = احتمال بروز حساسيت از طريق تماس با پوست وجود دارد .&lt;br /&gt;R44 = خطر انفجار بر اثر ايجاد گرما در فضاي بسته وجود دارد .&lt;br /&gt;R45 = احتمال بروز سرطان&lt;br /&gt;R46 = احتمال بروز صدمه ژنتيك ارثي&lt;br /&gt;R47 = احتمال بروز نقص در جنين&lt;br /&gt;R48 = خطر بروز صدمه جدي به انسان از باز گذاشتن طولاني آن&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;تركيب عوامل خطر R/.COMBINATION OF RISK FACTORS&lt;br /&gt;&lt;br /&gt;R14/15- با آب بشدت واكنش نشان داده و گازهاي قابل اشتعال بيشتري را آزاد ميكند .&lt;br /&gt;R15/29- تماس آن با آب ، گازهاي سمي و بسيار قابل اشتعال ايجاد ميكند .&lt;br /&gt;R20/21- استنشاق و تماس آن با پوست زيان ور است .&lt;br /&gt;R20/22- استنشاق ، و قورت دادن آن زيان آور است .&lt;br /&gt;R20/21/22- استنشاق ، تماس با پوست و قورت دادن آن زيان آور است&lt;br /&gt;R21/22- تماس با پوست و قورت دادن آن زيان آور است&lt;br /&gt;R23/24- استنشاق و تماس آن با پوست ايجاد مسموميت ميكند .&lt;br /&gt;R23/24/25- استنشاق ، تماس با پوست و خوردن آن مسموميت ايجاد مي كند .&lt;br /&gt;R24/25- خوردن و تماس آن با پوست مسموميت ايجاد ميكند .&lt;br /&gt;R26/27- استنشاق و تماس آن با پوست مسموعيت ايجاد مي كند .&lt;br /&gt;R26/28- استنشاق و خوردن آن مسموعيت شديد ايجاد مي كند .&lt;br /&gt;R26/27/28- استنشاق ، تماس با پوست و خوردن آن مسموميت ايجاد مي كند .&lt;br /&gt;R27/28- تماس با پوست و خوردن آن مسموميت شديد ايجاد ميكند .&lt;br /&gt;R36/37- سوزش آور ( تحريك كننده ) چشم و سيستم تنفسي است .&lt;br /&gt;R36/38- سوزش آور ( تحريك كننده ) چشم و پوست است .&lt;br /&gt;R36/37/38- سوزش آور ( تحريك كننده ) چشم ، سيستم تنفسي و پوست است .&lt;br /&gt;R37/38- سوزش آور ( تحريك كننده ) سيستم تنفسي و پوست است .&lt;br /&gt;R42/43- احتمال بروز حساسيت از طريق تماس با پوست و يا استنشاق آن وجود دارد .&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5848629110972031163?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5848629110972031163/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5848629110972031163&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5848629110972031163'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5848629110972031163'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_10.html' title='تفسير كدهاي ايمني طبق استاندارد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6977059117925588234</id><published>2011-01-10T13:18:00.000+03:30</published><updated>2011-01-10T13:20:20.727+03:30</updated><title type='text'>استاندارد بين المللي (E.E.C(European Common Market در مورد درج كدهاي ايمني بر روي بر چسب كالاها</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;br /&gt;كشورهاي بازار مشترك اروپا به منظور آگاهي مصرف كننده كالا از نحوه مصرف ، نحوه انبارداري ، حمل و نقل كالا ، وجود مواد سمي يا خطر ناك ، … كالاي ارائه شده اقدام به وضع مقرراتي كه ميبايستي بر روي بر چسب كالاها درج گردد نموده اند كه اين موضوع در مورد رنگها و حلالها كه غالبا"‌سمي ، قابل اشتعال و قابل انفجارند بشدت كنترل و رعايت ميگردد .&lt;br /&gt;همانگونه كه گفته شد بيشتر رنگها حاوي حلالها قابل اشتعال و بعضي از آنها براي پوست بدن مضر و يا در صورت ورود به مجاري تنفسي يا بلع ، سلامت انسان را به خطر مي اندازد لذا به منظور رعايت نكات ايمني در هنگام كار با رنگها لازمست كدهاي ايمني ايكه بر روي بر چسب كالاها نوشته شده است به دقت مورد مطالعه قرار گرفته و دقيقا" در هنگام اجراي رنگ آميزي بدانها عمل گردد . كدهاي ايمني ( علائم اختصاري ) كه به منظور آگاهي از نوع خطر و پيشگيري از آن در استاندارد بين المللي E.E.C آورده شده است و مفهوم هر يك از كدها بشرح زير ميباشد :&lt;br /&gt;&lt;strong&gt;الف - علائم خطر&lt;br /&gt;&lt;/strong&gt;+ F = شديد قابل اشتعال&lt;br /&gt;F‌ = قابل اشتعال&lt;br /&gt;+ T‌ = بسيار سمي&lt;br /&gt;T‌ = سمي&lt;br /&gt;Xn = زيان آور&lt;br /&gt;Xi = سوزش آور&lt;br /&gt;O = اكسيد كننده&lt;br /&gt;&lt;strong&gt;ب - علائم احتياط&lt;br /&gt;&lt;/strong&gt;R = نوع خطر&lt;br /&gt;S = علائم ايمني&lt;br /&gt;P = علائم اخطارهاي خاص&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6977059117925588234?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6977059117925588234/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6977059117925588234&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6977059117925588234'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6977059117925588234'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/eeceuropean-common-market.html' title='استاندارد بين المللي (E.E.C(European Common Market در مورد درج كدهاي ايمني بر روي بر چسب كالاها'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7045795202639085743</id><published>2011-01-04T08:06:00.000+03:30</published><updated>2011-01-04T08:07:54.250+03:30</updated><title type='text'>داستان مديريتي قهوه</title><content type='html'>&lt;span style="font-size:130%;"&gt;گروهي از فارغ التحصيلان پس از گذشت چند سال و تشکيل زندگي و رسيدن به موقعيت هاي خوب کاري و اجتماعي طبق قرار قبلي به ديدن يکي از اساتيد مجرب دانشگاه خود رفتند. بحث جمعي آن ها خيلي زود به گله و شکايت از استرس هاي ناشي از کار و زندگي کشيده شد. استاد براي پذيرايي از ميهمانان به آشپزخانه رفت و با يک قوري قهوه و تعدادي از انواع قهوه خوري‌هاي سراميکي، پلاستيکي و کريستال که برخي ساده و برخي گران قيمت بودند بازگشت. سيني را روي ميز گذاشت و از ميهمانان خواست تا از خود پذيرايي کنند . پس از آنکه همه براي خود قهوه ريختند استاد گفت: اگر دقت کرده باشيد حتما متوجه شده ايد که همگي قهوه خوري هاي گران قيمت و زيبا را برداشته ايد و آنها که ساده و ارزان قيمت بوده اند در سيني باقي مانده‌اند. البته اين امر براي شما طبيعي و بديهي است. سرچشمه همه مشکلات و استرس‌هاي شما هم همين است. شما فقط بهترين ها را براي خود مي‌خواهيد. قصد اصلي همه شما نوشيدن قهوه بود اما آگاهانه قهوه خوري هاي بهتر را انتخاب کرديد و البته در اين حين به آن چه ديگران برمي داشتند نيز توجه داشتيد. به اين ترتيب اگر زندگي قهوه باشد، شغل، پول، موقعيت اجتماعي و ... همان قهوه خوري هاي متعدد هستند. آنها فقط ابزاري براي حفظ و نگهداري زندگي اند، اما کيفيت زندگي در آنها فرق نخواهد داشت. گاهي، آن قدر حواس ما متوجه قهوه خوري‌هاست که اصلا طعم و مزه قهوه موجود در آن را نمي فهميم . پس دوستان من، حواستان به فنجان ها پرت نشود... به جاي آن از نوشيدن قهوه خود لذت ببريد.&lt;br /&gt;&lt;span style="color:#ffff00;"&gt;نتيجه گيري:&lt;br /&gt;&lt;/span&gt;کارهاي ساده را به راحتي مي توان پيچيده کرد، اما کارهاي پيچيده را به راحتي نمي توان ساده کرد. &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7045795202639085743?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7045795202639085743/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7045795202639085743&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7045795202639085743'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7045795202639085743'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_7306.html' title='داستان مديريتي قهوه'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5167672060163606773</id><published>2011-01-04T07:59:00.001+03:30</published><updated>2011-01-04T08:01:04.283+03:30</updated><title type='text'>نگاهي به كنگره‌هاي جهاني بهداشت و ايمني كار</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;نوزدهمين كنگره ايمني و بهداشت كار، كه از سال 1955 هر سه سال يك بار سازماندهي‌ شده است، در سال 2011 در تركيه برگزار خواهد شد. نخستين كنگره در رم و آخرين آن در سال 2008 در سئول برگزار شد. كنگره، كه براي تمام شركت‌ كنندگان فرصت تبادل اطلاعات و آفرينش انديشه‌هاي نو براي پيشگيري از بيماري‌هاي و حوادث كاري فراهم مي‌آورد، بزرگترين رويداد در اين زمينه است.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;هدف كنگره&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;هدف كنگره‌ي جهاني تضمين فرصت براي تبادل اطلاعات نو در باره ي بهداشت و ايمني شغلي در ميان افراد مربوطه با هدف افرينش فرهنگ پيشگيري در سطح جهاني است.&lt;br /&gt;هدف كساني كه در كنگره‌ي جهاني شركت مي‌كنندكسب ايده‌اي در اين باره است كه چگونه روابط بين دولت‌ها، كارفرمايان، سازمان‌هاي غيردولتي، نمايندگان كارفرمايان، كارگران و سازمان‌هاي آنان و حرفه‌اي‌هاي بهداشت و ايمني كار ارتقاء‌ يابد تا اسيب‌هاي و بيماري‌هاي ناشي از كار در سراسر جهان حذف شود. همچنين انتظار مي‌رود كه كنشگران بهداشت و ايمني شغلي اطلاعاتي در مورد ايده‌هاي عملي كسب كنند كه بتواند بي‌درنگ تصويب شده و به عمل درآيد.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;مخاطبان هدف&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;كنگره‌ي جهاني ايمني و بهداشت كار به كساني ارتباط مي‌يابد كه به صورت مستقيم يا غيرمستقيم با ايمني و بهداشت كار سروكار دارند:&lt;br /&gt;مهندسان و تكنيسين‌هاي بهداشت و ايمني‌ شغلي&lt;br /&gt;مقامات ارشد دولتي، تصميم‌سازان ارشد، مديران بالا، رهبران بازار، پزشكان كار و پزشكان محيط كار و كساني كه در عرصه‌ي بهداشت كار خدمت مي‌كنند.&lt;br /&gt;بازرسان كار، بازرسان فني كارخانه.&lt;br /&gt;مربيان و آموزگاران و افراد مرتبط با تربيت و آموزش.&lt;br /&gt;كارگران و نمايندگان آنان.&lt;br /&gt;كارفرمايان و نمايندگان آنان.&lt;br /&gt;تصميم‌سازان در بخش تأمين اجتماعي و بخش دولتي.&lt;br /&gt;مؤسسات خصوصي و عمومي.&lt;br /&gt;مؤسسات منطقه‌اي و بين‌المللي.&lt;br /&gt;توليد‌كنندگان و صادركنندگان.&lt;br /&gt;كارشناسان روابط عمومي و ارتباطات.&lt;br /&gt;نمايندگان رسانه و روزنامه‌نگاران.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;سازمان دهندگان كنگره‌ي جهاني بهداشت و ايمني شغلي&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;در مرحله‌ي مقدماتي كنگره جهاني بهداشت و ايمني شغلي سازمان‌هاي زير با يكديگر همكاري نزديك دارند:&lt;br /&gt;سازمان بين‌المللي كار&lt;br /&gt;انجمن بين‌المللي تأمين اجتماعي&lt;br /&gt;مؤسسه مسؤل بهداشت و ايمني شغلي در كشور ميزبان&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5167672060163606773?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5167672060163606773/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5167672060163606773&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5167672060163606773'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5167672060163606773'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_2999.html' title='نگاهي به كنگره‌هاي جهاني بهداشت و ايمني كار'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2562860655140010376</id><published>2011-01-04T07:32:00.000+03:30</published><updated>2011-01-04T07:33:37.574+03:30</updated><title type='text'>ماهيگير و تابه</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;span style="font-size:130%;"&gt;دو مرد در کنار درياچه اي مشغول ماهيگيري بودند . يکي از آنها ماهيگير با تجربه و ماهري بود اما ديگري ماهيگيري نمي دانست. هر بار که مرد با تجربه يک ماهي بزرگ مي گرفت ، آن را در ظرف يخي که در کنار دستش بود مي انداخت تا ماهي ها تازه بمانند ، اما ديگري به محض گرفتن يک ماهي بزرگ آنرا به دريا پرتاب مي کرد. ماهيگير با تجربه از اينکه مي ديد آن مرد چگونه ماهي را از دست مي دهد بسيار متعجب بود . لذا پس از مدتي از او پرسيد : چرا ماهي هاي به اين بزرگي را به دريا پرت مي کني ؟&lt;br /&gt;مرد جواب داد : آخر تابه من کوچک است!&lt;br /&gt;&lt;span style="color:#33ff33;"&gt;نتيجه گيري:&lt;br /&gt;&lt;/span&gt;گاهي ما نيز همانند همان مرد ، شانس هاي بزرگ ، شغل هاي بزرگ ، روياهاي بزرگ و فرصت هاي بزرگي که خداوند به ما ارزاني مي دارد را قبول نمي کنيم!&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2562860655140010376?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2562860655140010376/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2562860655140010376&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2562860655140010376'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2562860655140010376'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_04.html' title='ماهيگير و تابه'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3653411245234787548</id><published>2011-01-03T16:01:00.001+03:30</published><updated>2011-01-03T16:04:06.495+03:30</updated><title type='text'>اصلاح قانون کار ضروری است</title><content type='html'>&lt;a href="http://crtosh.irimlsa.ir/images/newspost_images/thumb_nazari_jalali_2.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 100px; DISPLAY: block; HEIGHT: 106px; CURSOR: hand" border="0" alt="" src="http://crtosh.irimlsa.ir/images/newspost_images/thumb_nazari_jalali_2.jpg" /&gt;&lt;/a&gt;مهندس نظري جلالي معاون روابط کار وزارت کار وامور اجتماعی در بازدید از شرکت نساجی کویر در سمنان گفت : 84 درصد قانون كار مرتبط با روابط كار است وباتوجه به گذشت 20سال از تصويب اين قانون، ضرورت به روز شدن و اصلاح برخي از مواد قانون كار جهت تسهيل روابط بين كارگران و كارفرمايان، احساس مي گردد.&lt;br /&gt;به گزارش روابط عمومی اداره کار وامور اجتماعی استان سمنان مهندس نظري جلالي معاون روابط كار وزارت كارواموراجتماعي و مديران كل ستادي طي سفر يك روزه به سمنان از شركت نساجي كوير بازديد به عمل آوردند.&lt;br /&gt;بر اساس این گزارش جلسه شوراي اداري اداره كل كارواموراجتماعي استان سمنان با حضور معاون وزیر کار و هیات همراه تشکیل شد واكرم مديركل كار و اموراجتماعي استان سمنان ضمن عرض تسليت به مناسبت شهادت سيد وسالار شهيدان حضرت اباعبداله الحسين(ع) وخيرمقدم به معاون محترم روابط كار وزارت كارواموراجتماعي و حاضرين گزارشی از عملكرد استاني اداره كل کار کرد .&lt;br /&gt;دراين جلسه معاون روابط كار وزارت كارواموراجتماعي مراجعات مردم به كاركنان رااز نعمتهاي خداوندي خواند و ادامه داد : ما جايي كار مي كنيم كه با حق و حقوق مردم درارتباط هستيم و عمل اگر فقط براي رضاي خدا انجام شود مورد قبول قرار مي گيرد.&lt;br /&gt;مهندس نظري جلالي بيان داشت كه 84 درصد قانون كار مرتبط با روابط كار است وباتوجه به گذشت 20سال از تصويب اين قانون، ضرورت به روز شدن و اصلاح برخي از مواد قانون كار جهت تسهيل روابط في مابين كارگران و كارفرمايان، احساس مي گرددو حدوث شرايط جديد و سرعت تغييرات بازاركار ايجاد مكانيزمي براي به روز ماندن مداوم قانون كار را ضروري مي سازد.&lt;br /&gt;وي تاكيدكردشعارمحوري ما، پايداري بنگاههاي توليدي است و بايد با لحاظ كردن اين رويكرد تلاشهايمان را جهت دهيم.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3653411245234787548?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3653411245234787548/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3653411245234787548&amp;isPopup=true' title='2 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3653411245234787548'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3653411245234787548'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post_03.html' title='اصلاح قانون کار ضروری است'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>2</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2613454277347036041</id><published>2011-01-01T13:00:00.000+03:30</published><updated>2011-01-01T13:02:10.870+03:30</updated><title type='text'>دو دانش آموز مصدوم حادثه برق گرفتگي در بندرعباس به بيمارستان يزد اعزام شدند</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;بندرعباس ـ دو نفر از چهار دانش آموزي كه روز گذشته بر اثر پاره شدن سيم هاي برق خيابان در بندرعباس دچار برق گرفتگي شدند به نام هاي همايون صبوران و حميدرضا سالاري ظهر دوشنبه به بيمارستان يزد اعزام شدند.&lt;br /&gt;رييس سازمان آموزش و پرورش استان ضمن تاييد برق گرفتگي چهار دانش آموز اظهار داشت:اين افراد در اولين ساعات صبح ديروز در مسير مدرسه دچار اين حادثه شده اند.&lt;br /&gt;احمد آخوندي دوشنبه در گفت و گو با ايرنا اسامي دانش آموزان را حميدرضا سالاري ،ياسر دروديان ،همايون صبوران و مهرشاد شجاعي اعلام كرد كه همگي دانش آموز سال دوم رشته كاردانش هنرستان شهيد تندگويان واقع در خيابان رسالت شمالي بندرعباس هستند.&lt;br /&gt;به گزارش ايرنا روز گذشته در اولين دقايق بارندگي بر اثر اتصال سيم تيرهاي برق و پاره شدن آنها،اين دانش آموزان دچار برق گرفتگي و سوختگي شده و پس از حضور نيروهاي امدادي و آتش نشاني ،توسط اورژانس 115 به بخش سوختگي بيمارستان شهيد محمدي منتقل شدند.&lt;br /&gt;بر اساس آخرين گزارش ها يكي ديگر از مصدومين اين حادثه به نام مهرشاد شجاعي از بيمارستان مرخص شده و ياسر دروديان نيز روز گذشته مورد مداواي سرپايي قرار گرفته است.&lt;br /&gt;ايرنا - تاريخ انتشار : 06/10/1389 - 15:54&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2613454277347036041?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2613454277347036041/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2613454277347036041&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2613454277347036041'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2613454277347036041'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2011/01/blog-post.html' title='دو دانش آموز مصدوم حادثه برق گرفتگي در بندرعباس به بيمارستان يزد اعزام شدند'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7308689022639506979</id><published>2010-12-25T11:38:00.005+03:30</published><updated>2010-12-25T11:52:15.557+03:30</updated><title type='text'>تصاویری از شبکه روشنایی معابر مالزی</title><content type='html'>&lt;a href="http://1.bp.blogspot.com/_o6rpep5dvIA/TRWpSqnvf_I/AAAAAAAAFEs/HwPwU_JrxVc/s1600/IMG_2417.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 214px; DISPLAY: block; HEIGHT: 320px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5554531853575094258" border="0" alt="" src="http://1.bp.blogspot.com/_o6rpep5dvIA/TRWpSqnvf_I/AAAAAAAAFEs/HwPwU_JrxVc/s320/IMG_2417.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 320px; DISPLAY: block; HEIGHT: 214px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5554529791914617922" border="0" alt="" src="http://3.bp.blogspot.com/_o6rpep5dvIA/TRWnaqVlLEI/AAAAAAAAFEc/-YV4MPHP2BM/s320/IMG_2415.jpg" /&gt;&lt;/div&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;&lt;a href="http://4.bp.blogspot.com/_o6rpep5dvIA/TRWpB2n5TKI/AAAAAAAAFEk/kX6peiROCvg/s1600/IMG_2416.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 214px; DISPLAY: block; HEIGHT: 320px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5554531564739185826" border="0" alt="" src="http://4.bp.blogspot.com/_o6rpep5dvIA/TRWpB2n5TKI/AAAAAAAAFEk/kX6peiROCvg/s320/IMG_2416.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div&gt;&lt;div&gt;&lt;a href="http://2.bp.blogspot.com/_o6rpep5dvIA/TRWnQDLiN4I/AAAAAAAAFEU/iLTVeaYnF88/s1600/IMG_2383.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 320px; DISPLAY: block; HEIGHT: 214px; CURSOR: hand" id="BLOGGER_PHOTO_ID_5554529609604806530" border="0" alt="" src="http://2.bp.blogspot.com/_o6rpep5dvIA/TRWnQDLiN4I/AAAAAAAAFEU/iLTVeaYnF88/s320/IMG_2383.jpg" /&gt;&lt;/a&gt; &lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7308689022639506979?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7308689022639506979/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7308689022639506979&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7308689022639506979'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7308689022639506979'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/12/blog-post_25.html' title='تصاویری از شبکه روشنایی معابر مالزی'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_o6rpep5dvIA/TRWpSqnvf_I/AAAAAAAAFEs/HwPwU_JrxVc/s72-c/IMG_2417.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8217000066125731255</id><published>2010-12-05T08:52:00.003+03:30</published><updated>2010-12-05T09:00:14.548+03:30</updated><title type='text'>وسيله اي مناسب براي بازنمودن در منهول</title><content type='html'>&lt;a href="http://www.gmptools.com/nf/images/70152_pixc.jpg"&gt;&lt;/a&gt;&lt;div dir="ltr" align="left"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 249px; DISPLAY: block; HEIGHT: 324px; CURSOR: hand" border="0" alt="" src="http://www.gmptools.com/nf/images/70152_pixd.jpg" /&gt;This lifter is for the individual faced with a wide variety of covers in their work environment.&lt;br /&gt;• The plated steel tubular body has been made thicker for the typically heavier electric utility manhole covers&lt;br /&gt;• The built in mechanical advantage allows you to remove even the most stubborn cover, while letting the lifter do the work, not your back&lt;br /&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 235px; DISPLAY: block; HEIGHT: 261px; CURSOR: hand" border="0" alt="" src="http://www.gmptools.com/nf/images/70152_pixbig.jpg" /&gt;&lt;br /&gt;• A spiked foot is incorporated into the design for improved traction on ground, sand, ice, snow or other loose surface&lt;br /&gt;• GMP offers multiple hooks or "keys" to be placed on the shackle at the end of the lifter's galvanized chain. This allows one tool to remove multiple cover types&lt;br /&gt;• The keys are heat treated steel for extra strength and durability &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8217000066125731255?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8217000066125731255/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8217000066125731255&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8217000066125731255'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8217000066125731255'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/12/blog-post_05.html' title='وسيله اي مناسب براي بازنمودن در منهول'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3091444542900141052</id><published>2010-12-04T13:21:00.003+03:30</published><updated>2010-12-04T13:27:49.856+03:30</updated><title type='text'>هند و خودروهاي حمل و نقل عمومي</title><content type='html'>&lt;a href="http://orangejuiceblog.com/wp-content/uploads/2009/07/india-greenhouse-gases-257x300.jpg"&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 257px; DISPLAY: block; HEIGHT: 300px; CURSOR: hand" border="0" alt="" src="http://orangejuiceblog.com/wp-content/uploads/2009/07/india-greenhouse-gases-257x300.jpg" /&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3091444542900141052?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3091444542900141052/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3091444542900141052&amp;isPopup=true' title='1 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3091444542900141052'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3091444542900141052'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/12/blog-post.html' title='هند و خودروهاي حمل و نقل عمومي'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5979954009354096198</id><published>2010-12-04T12:57:00.002+03:30</published><updated>2010-12-04T13:02:27.814+03:30</updated><title type='text'>High tech hard hats put on another safety hat</title><content type='html'>&lt;div dir="ltr" align="left"&gt;BY WHITNEY L.J. HOWELL - CORRESPONDENT&lt;br /&gt;DURHAM — Hard hats have long protected workers’ heads in calamities, and now engineers at Duke University are aiming to turn the hats into alarms when danger is present.&lt;br /&gt;According to the Occupational Safety &amp;amp; Health Administration (OSHA), more than 1,100 workers die and thousands more are injured on construction sites annually. A modified hard hat, dubbed the SmartHat, could reduce these numbers by sounding a warning when workers venture too close to large equipment.&lt;br /&gt;“Safety concerns are high when people and heavy equipment share the same space,” said Matt Reynolds,&lt;br /&gt;&lt;/div&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 368px; DISPLAY: block; HEIGHT: 246px; CURSOR: hand" border="0" alt="" src="http://wljhowell.files.wordpress.com/2010/10/smarthat-prototype.jpg?w=368&amp;amp;h=247" /&gt; &lt;p dir="ltr" align="left"&gt;The SmartHat, designed by a Duke University engineer, would send an alarm to a construction worker who gets too close to heavy equipment. Photo Courtesy: Duke University &lt;/p&gt;&lt;p dir="ltr" align="left"&gt;&lt;br /&gt;a Duke electrical and computer engineering researcher and SmartHat’s designer. “Most accidents and injuries occur because machine operators either don’t see workers or workers are faced away from the equipment.”&lt;br /&gt;The SmartHat technology piggybacks on existing wireless networks at construction sites that monitor vehicle locations. Each piece of heavy machinery carries a wireless transmitter that broadcasts its location.&lt;br /&gt;A silicon microprocessor, attached with Velcro to the crown of the SmartHat prototype, captures these free-floating radio-frequency waves with antennas. If the microprocessor determines the wearer is too close to equipment, it emits a high-pitched alarm that speeds up as man and machine move closer together.&lt;br /&gt;“The beeping is an annoying sound that workers can hear through the noise of the work site,” Reynolds said. “If we mount the microprocessor in the hard hat, we create an echo chamber to amplify the warnings.”&lt;br /&gt;However, the microprocessor’s ultimate location must be chosen carefully, said Jochen Teizer, a civil and environmental engineer at the Georgia Institute of Technology. OSHA requires that nothing compromise a hard hat’s ability to protect the wearer’s head during an accident.&lt;br /&gt;“Including the SmartHat technology can’t create any danger to the wearer, such as creating a pinch point that could cause injury,” Teizer said. “For the technology to be feasible, you need to integrate it inside the hard hat. Integrating it into the plastic would be the final solution.”&lt;br /&gt;Microprocessors should also have an extensive range, he said, to alert workers to fast-moving machinery. &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5979954009354096198?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5979954009354096198/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5979954009354096198&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5979954009354096198'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5979954009354096198'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/12/high-tech-hard-hats-put-on-another.html' title='High tech hard hats put on another safety hat'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7144096386115754568</id><published>2010-11-24T07:29:00.004+03:30</published><updated>2010-11-24T07:59:11.751+03:30</updated><title type='text'>تصوير لاشه پلنگ نر بالغ روي دكل برق</title><content type='html'>&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 352px; CURSOR: hand; HEIGHT: 508px; TEXT-ALIGN: center" alt="" src="http://up.persian.be/out.php/i254_1.jpg" border="0" /&gt; &lt;strong&gt;&lt;span style="color:#ffff00;"&gt;لاشه یک پلنگ نر بالغ، دو روز قبل بر بالای یک دکل برق فشار قوی پیدا شد. محیط بانان در تربت جام پس از پایین آوردن لاشه متوجه شدند که پلنگ به ضرب چهار گلوله کشته شده است. تحقیقات درباره عاملان شلیک این گلوله‌ها ادامه دارد.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 347px; CURSOR: hand; HEIGHT: 517px; TEXT-ALIGN: center" alt="" src="http://up.persian.be/out.php/i255_2.jpg" border="0" /&gt;&lt;br /&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 337px; CURSOR: hand; HEIGHT: 236px; TEXT-ALIGN: center" alt="" src="http://up.persian.be/out.php/i256_3.jpg" border="0" /&gt;&lt;br /&gt;منبع:  ایرانه روز دات کام&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7144096386115754568?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7144096386115754568/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7144096386115754568&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7144096386115754568'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7144096386115754568'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_24.html' title='تصوير لاشه پلنگ نر بالغ روي دكل برق'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-23565140422806142</id><published>2010-11-22T17:06:00.003+03:30</published><updated>2011-01-04T07:58:19.201+03:30</updated><title type='text'>قلک عمر</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;آقاي Brown پيرمرد 80 ساله با غرور و بالندگي خاص پس از اصلاح صورت خود در مقابل آينه ايستاد ، برسي بدست گرفته موهايش را به سبکي بسيار زيبا مانند روز ازدواجش شانه کرد، کرواتش را مرتب کرد و راس ساعت 8 صبح به سمت خانه سالمندان حرکت کرد ، او همسر و بينايي اش را در اثر حادثه چند سال پيش از دست داده بود. پس از ورود به خانه سالمندان متوجه شد که کسي در قسمت پذيرش حضور ندارد تا به او خير مقدم بگويد، به همين خاطر مجبور بود تا لحظاتي را صبر کند تا مسوول پذيرش متوجه حضور وي شود. در اينجا فرصتي برايش حاصل شد تا به ياد همسر 72 ساله اش که ساليان سال با هم عمر مشترک را گذرانده بودند بيفتد و خاطرات خوبش با او در ذهنش مرور کند .&lt;br /&gt;بعد از نيم ساعت من در قسمت پذيرش حاضر شدم و به او گفتم سلام آقاي Brown از اينکه تأخير کردم پوزش مي طلبم داشتم اتاق شما را مرتب مي کردم اتاق شما هم اکنون حاضر است اجازه دهيد شما را به سمت اتاقتان راهنمايي کنم .&lt;br /&gt;به همراه او با پاي رنجورش و با Walker به سمت آسانسور پيش رفتيم و در حين راه از خصوصيات اتاق کوچکي که قرار بود تا آخر عمرش در آنجا زندگي کند حرف زدم از رنگ ديوارها و سايه روشن هاي روي پنجره برايش تعريف کردم. بعد از پايان حرفهايم مثل يک بچه شاد 8 ساله که انگار يک سگ کوچولو بهش جايزه داده اند با شادي وصف ناپذيري گفت که عاشق اينجور جاها هستم.&lt;br /&gt;به او گفتم اما آقاي Brown شما که اتاق را نمي توانيد ببينيد . در جوابم گفت پسرم خوشي و شادي چيزي است که زودتر از وقوع يک چيز حادث مي شود. اينکه من از اتاقم خوشم بيايد يا نه به طرز چيدمان اسباب اثاثيه درون اتاق ربطي ندارد بلکه اين موضوع به طرز سرو سامان دادن افکار من بستگي دارد. من در حال حاضر دوست دارم که عاشق اون اتاق باشم اين تصميمي است که امروز صبح که از خواب برخواستم گرفتم من هر روز صبح که از خواب برمي خيزم فقط يک انتخاب مي توانم داشت باشم. مي توانم تمام روز در رختخوابم دراز بکشم و مشکلات و نواقصي که در اعضاي بدنم هست و در ضمن، از کار هم افتاده اند را بشمارم يا اينکه از رختخواب بيرون بيايم و از خدا بخاطر آندسته از اعضاي بدنم که سالم هستند شکر گذار بوده و به خاطرات خوشي که قرار است طي روز برايم اتفاق بيفتد فکر مي کنم .&lt;br /&gt;پيري مثل يک حساب بانکي يا قلک مي ماند. تو از درون اون چيزهايي را بيرون مي کشي که در جواني ذخيره کرده اي پس نصيحت من به تو اينست که در حساب بانکي عمرت خاطرات خوش و لحظات خوب را ذخيره کني. در ضمن ، از اينکه با توصيف قشنگت از اتاقي که قراره توش باشم به قلک زندگي من چيزهاي زيبا اضافه کردي ممنونم. بگذار پنج قانون ساده خوشحالي را برايت بشمارم.&lt;br /&gt;اول: قلبت را از هر چيز که باعث تنفر مي شه آزاد کن.&lt;br /&gt;دوم: ذهنت را از هر نگراني پاک کن.&lt;br /&gt;سوم: خيلي ساده زندگي کن.&lt;br /&gt;چهارم: به ديگران از نعماتي که داري ببخش .&lt;br /&gt;پنجم: از ديگران هم انتظاري نداشته باش.&lt;br /&gt;و در حاليکه لبخند مي زد وارد اتاقش شد و زير لب شعري را زمزمه کرد و درب را پشت سرش بست.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;نتيجه گيري:&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;چه بسا انسانهايي که خوشبختي خود را شرطي مي کنند.&lt;br /&gt;چه بسا مديران و کارشناساني که بهره وري خود را مشروط مي دانند.&lt;br /&gt;غافل از آنکه احساس خوشبختي يا نگرش بهره وري در ذهن و در افکار ما بايد ايجاد گردد و مي تواند مستقل از محيط پيرامون يا ساير شرايط باشد.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-23565140422806142?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/23565140422806142/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=23565140422806142&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/23565140422806142'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/23565140422806142'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_1657.html' title='قلک عمر'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1371198980859599564</id><published>2010-11-22T17:06:00.001+03:30</published><updated>2010-11-22T17:08:08.716+03:30</updated><title type='text'>هفت نکته برای غذا خوردن در محل کار</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;در هنگام غذا خوردن چشمتان به ظرف غذا و غذایی که می خورید باشد و وقتی که پشت میز کار غذا می خورید حواستان به غذایی که در دهان می گذارید باشد و اجازه ندهید که به خاطر اینکه حواستان معطوف یک ایمیل و یا یک مورد کاری است بیش از حد غذا بخورید .&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;امروزه بسیاری از افراد برای چندین بار در هفته غذای خود را پشت میز کارشان میل می کنند. ولی در هر حال میز کارتان مکان مناسبی برای غذا خوردن نیست و غذا خوردن سر میز کار و جلوی کامپیوتر مشکلاتی را به همراه دارد. لذا در این مقاله ابتدا به دلایل اینکه چرا نباید پشت میز کار غذا بخورید می پردازیم، و سپس از آنجا که بسیاری از افراد گزینه دیگری ندارند و مجبور هستند غذایشان را پشت میز کارشان میل کنند در ادامه مطلب نکاتی را برای چگونگی تغذیه سالم تر در محیط کار و پشت میز کار بیان می داریم.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;عوارض غذا خوردن پشت میز کار&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;یکی از بزرگترین عوارض غذا خوردن پشت میز کار آن است که نمی توانید بر روی غذای مصرفی خودتان تمرکز و توجه کافی داشته باشید. وقتی شما به جای تمرکز بر غذای مصرفی تان سرگرم فرستادن ایمیل و پاسخ به تلفن و مرتب کردن اوراق باشید ممکن است ناخواسته پرخوری کنید در واقع صرف غذا پشت میز کار، باعث عدم تمرکز بر میزان غذای مصرفی در شما می باشد. وقتی شما در پشت میز کار نشسته اید این احتمال زیاد است که چند کار را با هم انجام دهید و به مقدار غذای مصرفی تان توجه کافی نداشته باشید. در واقع غذا خوردن پشت میز کار به این معناست که شما به جای نشستن پشت کامپیوتر برای 8 ساعت در روز ، در واقع برای 9 ساعت در روز این کار را می کنید.&lt;br /&gt;غذا خوردن پشت میز کار از بلند شدن از سر جایتان و فاصله گرفتن از دفتر کار و یا محل کارتان جلوگیری می نماید ولی شما برای بهبود پمپاژ قلب و جریان خونتان نیازمند قدری استراحت و حرکت هستید. لذا زمان صرف ناهار بسیار مهم است و این فرصت را به شما می دهد که این استراحت را در روز تجربه نمایید. ولی اگر شما پشت میز کارتان باقی بمانید این فرصت را از خود می گیرید.&lt;br /&gt;به غیر از عوارض مذکور، غذا خوردن پشت میز کار یک مکان مناسب روزانه برای رشد باکتری ها و میکروب ها را فراهم می کند. در ضمن اگر از جمله افرادی هستید که وسط غذا خوردنتان به دلیل کار از جای خود بلند می شوید و برای مثال نیم ساعت از خوردن ناهار باز می مانید و مجددا باز می گردید و به دلیل پر مشغله بودن صرف ناهارتان مدت زیادی طول می کشد پس جای نگرانی هایی از بابت درجه حرارت و ایمنی و رشد میکروب در غذایتان وجود دارد. به عبارت دیگر در درجه حرارت اتاق بسیاری از غذاها می توانند محیط مناسبی برای رشد باکتری ها گردند.&lt;br /&gt;میز غذایی که محل خوردن غذاها و خوراکی ها می باشد می تواند بسیار آلوده باشد و در واقع صرف غذا و خوراکی پشت میز کار به ویژه وقتی که نظافت و تمیز کردن منظم میز کار رعایت نشود می تواند میز را به یک کافه تریا برای باکتری ها مبدل کند. وقتی همزمان با صرف غذا کار کنید گوشی تلفن شما و صفحه کلید کامپیوتر و موس و همه ابزار های شما آلوده خواهند شد. برای آزمایش کردن میزان آلودگی میز کارتان صفحه کلید (کی برد) را بعد از صرف غذا برعکس کنید و نگاه کنید که چقدر خرده نان و خرده غذا از آن بیرون می ریزد هر چقدر که ریزش خرده غذاها بیشتر باشد یعنی شما در آلوده کردن میز کارتان موفق تر بوده اید.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;نکاتی برای غذا خوردن سالم تر در پشت میز کار&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;اگر علی رغم همه توضیحات فوق الذکر، بازهم می خواهید غذایتان را پشت میز کارتان میل کنید و در واقع چاره دیگری ندارید. در اینجا راهکارهایی را برای تغذیه سالم در پشت میز کار بیان می داریم:&lt;br /&gt;1- در هنگام غذا خوردن چشمتان به ظرف غذا و غذایی که می خورید باشد و وقتی که پشت میز کار غذا می خورید حواستان به غذایی که در دهان می گذارید باشد و اجازه ندهید که به خاطر اینکه حواستان معطوف یک ایمیل و یا یک مورد کاری است بیش از حد غذا بخورید . برای غذای ناهار باید یک وعده غذایی با حجم متعادل را مصرف نمایید ولی نه در حدی که احساس سیری بیش از حد و رخوت بعد از صرف غذا را داشته باشید.&lt;br /&gt;2- ناهارتان را خودتان از منزل بیاورید و از غذاهای پرکالری و فست فود اجتناب کنید. در واقع ناهار فرصت خوبی است برای اینکه غذاهای سالم بخورید لذا با خود غذاهای سالم و سبک و سالاد ( مثل سالاد مرغ و سبزیجات) و آجیل و... بیاورید. اگر با خود غذاهای سالم حاوی سبزیجات را بیاورید مواد مغذی مهم از جمله پروتئین و فیبر را دریافت می نمایید. از مصرف ناهار های گران قیمت و پر حجم و پرکالری و پر چرب که مواد مغذی چندانی هم ندارند پرهیز نمایید. برای حفظ ایمنی غذا از ظروف مخصوص غذا که غذا را خنک نگه می دارند برای حمل غذا استفاده کنید و سپس آن را به یخچال موجود در محل کارتان منتقل نمایید و اجازه ندهید منتقل کردن غذایتان به یخچال بیش از 2 ساعت به طول انجامد.&lt;br /&gt;3- هر زمان که فرصت داشتید به قدم زدن و پیاده روی بپردازید. ما به طور ژنتیکی برای حرکت خلق شده ایم نه سکون، بنابراین صرف غذا پشت میز کار در جایی که روز طولانی ای را بدین منوال در پیش رو دارید ایده خوبی نیست. اگر مجبور هستید که پشت میزتان غذایتان را صرف کنید به دنبال راهکارهایی برای حرکت در بقیه اوقات روزتان باشید. سعی کنید در مسیر برگشت به خانه قدری پیاده روی داشته باشید. بهتر است برای پیشگیری از یک الگوی زندگی ساکن و بدون حرکت در هنگام بیدار شدن از خواب و یا در اواخر روز قدری پیاده روی و ورزش داشته باشید.&lt;br /&gt;4- میز کار خود را تمیز و ضد عفونی کنید. روزی یکبار تمیز کردن میز کارتان با مواد ضد عفونی کننده کافی است. پاک کردن میز تنها با دستمال کاغذی فایده چندانی ندارد و در از بین بردن آلودگی ها موثر نیست. از تمیز بودن تلفن و کامپیوتر و موس و صفحه کلیدتان اطمینان حاصل کنید و از لمس کردن آنها در هنگام صرف غذا اجتناب کنید. همچنین برای جلوگیری از آلوده شدن غذایتان نظافت دستانتان را رعایت کنید و شست و شوی دست ها قبل از غذا را انجام دهید و همچنین یک ضد عفونی کننده برای دست را همیشه در کشوی محل کارتان داشته باشید.&lt;br /&gt;5- می توانید در هنگام صرف غذا بر روی میز کارتان از یک روکش یا رومیزی کوچک استفاده کنید که مانعی خواهند بود بین میکروبها و غذای شما.&lt;br /&gt;6- غذایتان را به همراه یک دوست یا همکار صرف نمایید تا فرصتی را برای استراحت و تجدید روحیه و تعامل با همکاران به خود بدهید.&lt;br /&gt;7- غذا خوردن پشت میز کار را تبدیل به یک عادت برای خود نکنید. برخی مواقع برای شما میسر است که غذایتان را پشت میز کارتان نخورید ولی چون تبدیل به عادت شده است ناخواسته پشت میز کار غذا می خورید (حتی گاهی در منزل خودتان!) و این رفتار غلط تبدیل به یکی از عادت های روزمره تان می گردد. لذا هر زمان که برایتان میسر شد غذایتان را در آرامش و مکان مناسب تر میل کنید.&lt;br /&gt;تابناک&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1371198980859599564?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1371198980859599564/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1371198980859599564&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1371198980859599564'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1371198980859599564'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_547.html' title='هفت نکته برای غذا خوردن در محل کار'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2231103620606431263</id><published>2010-11-22T16:27:00.001+03:30</published><updated>2010-11-22T16:35:12.231+03:30</updated><title type='text'>نخستين نوع فازمتر هوشمند در ايران طراحي و ساخته شد</title><content type='html'>&lt;a href="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=246&amp;amp;viewkey="&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 359px; CURSOR: hand; HEIGHT: 210px; TEXT-ALIGN: center" alt="" src="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=246&amp;amp;viewkey=" border="0" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;color:#ffff00;"&gt;&lt;strong&gt;شهركرد-نخستين نوع فني فازمترهاي هوشمند و غيرلمسي از سوي محققان و مخترعان ايراني طراحي و ساخته شد. &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;طراح و مخترع نخستين نوع از فازمترهاي فني غيرلمسي در ايران گفت: اين فازمتر با شماره 312186در شركت ثبت اختراعات صنعتي به نام جمهوري اسلامي ايران به ثبت رسيده است. 'ايمر هوشنگ سازگار' در حاشيه چهارمين روز از نمايشگاه اختراعات،ابتكارات و ايده هاي برتر مخترعان ايراني در بروجن در گفت وگو با ايرنا افزود:دانش نوعي از اين فازمترها پيش از اين تنها در اختيار سه كشور آمريكا،ژاپن و آلمان بود كه با ساخت و طراحي آن در ايران، انحصار دانش فازمترهاي غيرلمسي درجهان شكسته شد وايران نيز به جمع دارندگان اين دانش پيوست. &lt;/span&gt;&lt;br /&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;سازگار افزود:اين نوع فازمتر بدون نياز به لمس انگشت،‌قادر به نمايش اتصال جريان برق و الكتريسته در همه سيستم هاست و قطعي برق در يك سيستم الكترونيكي را براحتي نيز نشان مي دهد. وي تصريح كرد:فناوري و دانش به كار رفته در اين فازمتر بگونه اي است كه اين فازمتر قادر به تشخيص اتصال جريان برق در زير آب نيز مي باشد و اين قطعه فني اتصال برق از نيم ولت به بالاتر را نشان مي دهد. اين مخترع كشور يادآور شد:اين فازمتر قادر به تشخيص شكستگي پايه هاي ترانسفورهاي مغناطيسي است كه تاكنون هيچ نوع از فازمترها چنين خاصيتي نداشته اند. &lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;به گفته وي،اين نوع فازمترهاي هوشمند قدرت تشخيص پالس هاي تلفن و مركز تماس گيرنده با تلفن را نيز دارد و حتي ترك هاي مويي سيستم هاي الكترونيكي را نيز تشخيص مي دهد. وي گفت: با توليد انبوه اين نوع فازمتر در كشور ،بزودي ايران نيزبه جمع صادر كنندگان اين فناوري برتر در جهان تبديل مي شود. به گزارش ايرنا،جشنواره و نمايشگاه ابداعات و اختراعات برتر ايران به مدت يك هفته در سالن 'شهيد قنبرعلي فهميده' بروجن چهارمحال وبختياري در حال پيگيري است. &lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2231103620606431263?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2231103620606431263/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2231103620606431263&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2231103620606431263'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2231103620606431263'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_22.html' title='نخستين نوع فازمتر هوشمند در ايران طراحي و ساخته شد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8567456446665094490</id><published>2010-11-17T15:40:00.000+03:30</published><updated>2010-11-17T15:41:33.336+03:30</updated><title type='text'>NFPA releases 2009 Edition of NFPA 70E</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;p dir="ltr" align="left"&gt;By W. Jon Wallace, CSP, MBA&lt;br /&gt;The National Fire Protection Association (NFPA) issued the revised 2009 edition of NFPA 70E®: Standard for Electrical Safety in the Workplace with an effective date of September 5, 2008. The 2009 edition of NFPA 70E® contains numerous revisions. Listed below is a summary of the major changes:&lt;br /&gt;Contractor Relationships: Article 110.5 requires host employers inform contractors of known hazards covered by NFPA 70E® related to the contract employer’s work. The contract employer shall ensure that each of his/her employees is instructed in the hazards provided by the employer.&lt;br /&gt;Training Requirements – Emergency Procedures: Article 110.6 requires employees exposed to shock hazards that are not reduced to a safe level by applicable electrical installation requirements be trained in approved methods of resuscitation, including cardiopulmonary resuscitation (CPR). The training shall be certified annually by the employer.&lt;br /&gt;Electrical Safety Program Audit: Article 110.7 requires the written electrical safety program be audited on a frequency established by the employer.&lt;br /&gt;Arc Flash Hazard Analysis: Article 130.3 requires the arc flash hazard analysis be updated whenever a major modification or renovation takes place. In addition, the analysis shall be reviewed periodically, not to exceed five years.&lt;br /&gt;Arc Flash Protection Boundary: The criteria for the 4 feet arc flash protection boundary for voltage levels between 50 and 600 volts has been modified based on upstream protection device clearing time of maximum 2 cycles (0.033 seconds) and available bolted fault current of 50 kA or any combination not exceeding 100 kA cycles.&lt;br /&gt;Equipment Labeling: Article 130.3 (C) states equipment shall be field marked with a label containing the available incident energy or required level of PPE.&lt;br /&gt;Selection of Personal Protective Equipment: Article 130.7 contains several revisions with respect to arc flash PPE requirements. For example: Table 130.7 (C)(9) has been expanded to include additional job tasks such as performing infrared thermography as well as other non-contact inspections outside the restricted approach boundary. Additional categories of equipment, such as arc-resistant switchgear, have been added to the revised table. Table 130.7 (C)(10) has been revised and placed an a more user-friendly format.&lt;br /&gt;Annex Revisions: The following annexes have been significantly revised – Annex F (Hazard/Risk Evaluation Procedure); Annex H (Simplified, Two-Category, Flame-Resistant [FR] Clothing System).&lt;br /&gt;Please remember this article is intended as an overview and not a comprehensive summary of changes to the 2009 edition of NFPA 70E®. &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8567456446665094490?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8567456446665094490/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8567456446665094490&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8567456446665094490'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8567456446665094490'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/nfpa-releases-2009-edition-of-nfpa-70e.html' title='NFPA releases 2009 Edition of NFPA 70E'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5141739575669322848</id><published>2010-11-16T13:11:00.005+03:30</published><updated>2011-08-21T01:21:00.935+04:30</updated><title type='text'>تصاوير مانور گروه هاي خط گرم فرمان از نزديك ( لمس مدار ) شركت توزيع برق نيروي برق شهرستان مشهد</title><content type='html'>&lt;a href="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=238&amp;amp;viewkey="&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 352px; DISPLAY: block; HEIGHT: 229px; CURSOR: hand" border="0" alt="" src="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=238&amp;amp;viewkey=" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;a href="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=239&amp;amp;viewkey="&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 356px; DISPLAY: block; HEIGHT: 217px; CURSOR: hand" border="0" alt="" src="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=239&amp;amp;viewkey=" /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5141739575669322848?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5141739575669322848/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5141739575669322848&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5141739575669322848'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5141739575669322848'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_2688.html' title='تصاوير مانور گروه هاي خط گرم فرمان از نزديك ( لمس مدار ) شركت توزيع برق نيروي برق شهرستان مشهد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4380727727519854026</id><published>2010-11-16T10:45:00.003+03:30</published><updated>2010-11-16T10:53:49.658+03:30</updated><title type='text'>تصوير يك سيمبان هات لاين ، با تجهيزات كاملاً حرفه اي</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=218&amp;amp;viewkey="&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 304px; CURSOR: hand; HEIGHT: 391px; TEXT-ALIGN: center" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=218&amp;amp;viewkey=" border="0" /&gt;&lt;/a&gt; &lt;span style="font-size:130%;"&gt;در سرويس و نگهداري تجهيزات داخل پست هاي زميني و هوايي كه بصورت ادواري انجام مي گردد ، معمولاً اينكار با خاموشي انجام مي گرديد &lt;span style="color:#33ff33;"&gt;كه &lt;strong&gt;در شركت توزيع نيروي برق شهرستان مشهد با آموزش نيروهاي متخصص و با استفاده از تجهيزات روز و متناسب كار ، در شرايط ايمن ، اينكار بدون خاموشي و بصورت برقدار ( HOT LINE ) در حال انجام است.&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4380727727519854026?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4380727727519854026/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4380727727519854026&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4380727727519854026'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4380727727519854026'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_16.html' title='تصوير يك سيمبان هات لاين ، با تجهيزات كاملاً حرفه اي'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5227033043190774656</id><published>2010-11-16T10:17:00.003+03:30</published><updated>2010-11-17T15:37:41.772+03:30</updated><title type='text'>Electric Arc Flash PPE: Outer Garment Protection</title><content type='html'>&lt;div dir="ltr" align="left"&gt;&lt;a href="http://www.workplace-safety-nc.com/images/arc-flash-ppe.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 300px; CURSOR: hand; HEIGHT: 179px; TEXT-ALIGN: center" alt="" src="http://www.workplace-safety-nc.com/images/arc-flash-ppe.jpg" border="0" /&gt;&lt;/a&gt;By W. Jon Wallace, CSP, MBA; Workplace Safety and Hugh Hoagland: e-hazard.com &lt;/div&gt;&lt;div dir="ltr" align="left"&gt;Due to the potential of an electric arc flash, many employees who perform work on energized conductors (qualified persons) are exchanging flammable and/or meltable clothing, such as pants and shirts, for flame resistant (FR) clothing. In recent years qualified persons are increasingly wearing flame resistant clothing as a daily wear garment for protection against electric arc flashes. It is important to note, however, that a workers’ outer garment also needs to be flame resistant. Otherwise, the worker may suffer severe injuries during an electric arc flash. In this article, we will discuss the appropriate outer garments needed for qualified persons.&lt;br /&gt;Rainwear: Qualified persons who perform work on energized conductors while working outside typically wear rainwear (rain jacket and pants) during rain showers. Most rainwear, however, are made from meltable fabrics that could melt during an arc flash. Also, although rainwear often says it is flame resistant (FR) this may have no correlation to an actual hazard. Many materials in the United States are still marked with FR even when it only passes a vertical flame test. This test has no correlation to how a material will perform in flash fire OR electric arc – most of this rainwear will melt. Therefore, only arc resistant rainwear complying with ASTM F1891: Standard Specification for Arc and Flame Resistant Rainwear should be worn by qualified persons.&lt;br /&gt;Cold Weather Protection: If an outer jacket or coat is worn by a qualified person, the garment must meet the requirements of ASTM F1506: Standard Performance Specification for Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards.&lt;br /&gt;Fall Protection – Full Body Harness: Qualified persons commonly perform work tasks on energized conductors from elevated heights, such as in an aerial lift. Fall protection typically consists of a full body harness and lanyard. To ensure the fall protection is not destroyed during an arc flash, use a full body harness and lanyard satisfying the requirements of ASTM F887: Standard Specifications for Personal Climbing Equipment. These harness designs have been subjected to a 40 cal/cm² arc test and must still pass the drop test afterward. Kevlar harnesses, which are becoming increasingly popular, have an added advantage of sustaining no ignition, melting or dripping at any exposure.&lt;br /&gt;FDA, Cleanroom Applications: Employees working in FDA covered facilities are required to wear hairnets and/or beardnets. www.ArcStore.com, Salisbury, and NSA Manufacturing offer arc-rated nets for used in FDA applications. For cleanrooms, several companies offer arc rated cleanroom suits including White Knight Engineering, Universal Overall and Oberon. Each of these has differing characteristics and not all cleanroom suits will meet your criteria – check with the manufacturer.&lt;br /&gt;In summary, although daily wear flame resistant (FR) clothing provides significant protection to qualified workers in the event of an arc flash, sometimes additional protection is needed. Review all work tasks performed by your qualified persons to ensure outer garments provide adequate protection. &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5227033043190774656?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5227033043190774656/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5227033043190774656&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5227033043190774656'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5227033043190774656'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/electric-arc-flash-ppe-outer-garment.html' title='Electric Arc Flash PPE: Outer Garment Protection'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6056710020521259212</id><published>2010-11-15T14:30:00.005+03:30</published><updated>2011-08-21T01:22:47.440+04:30</updated><title type='text'>نصب تير با استفاده از روش خط گرم فرمان از نزديك ( HOT LINE ) در توزيع برق مشهد</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=208&amp;amp;viewkey="&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 344px; DISPLAY: block; HEIGHT: 219px; CURSOR: hand" border="0" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=208&amp;amp;viewkey=" /&gt;&lt;/a&gt; با توجه به مشكلات ناشي از قطع برق در جامعه و نيز صنايع ، لذا شركت توزيع نيروي برق شهرستان مشهد با بكارگيري نيروهاي آموزش ديده و حرفه اي و نيز تجهيزات روز ، فعاليت هاي تعميراتي خود را در سطح شهر بدون خاموشي و با استفاده از روش خط گرم فرمان از نزديك ( HOT LINE ) يا لمس مدار انجام مي دهد كه تصوير يكي از اين كارگاه ها را در بالا مشاهده مي نماييد كه تيرسيماني در بين شبكه برقدار با دستگاه لاين تراك جابجا و در حال نصب مي باشند.&lt;br /&gt;&lt;br /&gt;&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6056710020521259212?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6056710020521259212/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6056710020521259212&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6056710020521259212'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6056710020521259212'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/hot-line_15.html' title='نصب تير با استفاده از روش خط گرم فرمان از نزديك ( HOT LINE ) در توزيع برق مشهد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7327022083397174818</id><published>2010-11-15T13:30:00.003+03:30</published><updated>2010-11-15T14:44:24.025+03:30</updated><title type='text'>تهيه و چاپ كتابچه توصيه ايمني برق در فعاليت هاي عمراني و ساختماني</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=193&amp;amp;viewkey="&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 281px; CURSOR: hand; HEIGHT: 323px; TEXT-ALIGN: center" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=193&amp;amp;viewkey=" border="0" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;از آنجاييكه بخشي از آمار حوادث الكتريكي رويداده در سطح جامعه ، مرتبط با صنعت ساخت و ساز مي باشد ، لذا دفتر ايمني شركت توزيع نيروي برق شهرستان مشهد در راستاي تحقق اهداف بلند مدت ايمني و بهداشت شغلي سازمان، يعني آگاه سازي گروه هاي ذينفع ( مردم و مهندسين و كارفرمايان ) از مخاطرات بالقوه الكتريكي تأسيسات و شبكه هاي هوايي برق ، كه معمولاً همجوار با پروژه ها مي باشند ، اقدام به تهيه و چاپ كتابچه توصيه ايمني برق در فعاليت هاي عمراني و ساختماني نموده است.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;قرار است اين كتابچه در اختيارسازمان نظام مهندسي ساختمان و نيز بخش صدور پروانه ساختماني شهرداري و ديگر سازمان هاي مرتبط قرار گرفته تا در بين افراد ذينفع توزيع گردد.&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7327022083397174818?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7327022083397174818/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7327022083397174818&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7327022083397174818'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7327022083397174818'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_2132.html' title='تهيه و چاپ كتابچه توصيه ايمني برق در فعاليت هاي عمراني و ساختماني'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1280101468106150348</id><published>2010-11-15T12:02:00.005+03:30</published><updated>2011-08-21T01:26:54.147+04:30</updated><title type='text'>مجموعه تصاوير اجراي خط گرم ( HOT LINE ) فرمان از نزديك ( لمس مدار )</title><content type='html'>&lt;a href="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=201&amp;amp;viewkey="&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 341px; DISPLAY: block; HEIGHT: 236px; CURSOR: hand" border="0" alt="" src="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=201&amp;amp;viewkey=" /&gt;&lt;/a&gt;در حال حاضر گروه هاي خط گرم، در شركت توزيع نيروي برق شهرستان مشهد با استفاده از تجهيزات روز در سطح شهرستان مشهد اكثر فعاليت هاي اجرايي و تعميراتي شبكه ها را بدون خاموشي انجام مي دهند.&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;a href="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=225&amp;amp;viewkey="&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 320px; DISPLAY: block; HEIGHT: 211px; CURSOR: hand" border="0" alt="" src="http://www.ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=225&amp;amp;viewkey=" /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1280101468106150348?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1280101468106150348/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1280101468106150348&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1280101468106150348'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1280101468106150348'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/hot-line.html' title='مجموعه تصاوير اجراي خط گرم ( HOT LINE ) فرمان از نزديك ( لمس مدار )'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5297762633202785530</id><published>2010-11-15T08:35:00.002+03:30</published><updated>2010-11-15T08:49:12.823+03:30</updated><title type='text'>دومين همايش ملي ايمني ساختمان</title><content type='html'>&lt;div dir="rtl" align="right"&gt;اين همايش توسط موسسه خانه عمران روز پنجشنبه 19 آبان 1389 در مركز همايشهاي بين المللي دانشگاه شهيد بهشتي تهران، با حضور دست اندركان، صاحب نظران و متخصصان و فعالان صنعت ساختمان و مسئولين و نمايندگان وزارتخانه هاي كار و امور اجتماعي، بهداشت و درمان، مسكن و شهرسازي، سازمانهاي نظام مهندسي و شهرداري آغاز به كار نمود.&lt;br /&gt;در روز اول 33 مقاله در سه سالن بصورت موازي در حوزه هاي مختلف فني و مديريتي در زمينه ايمني ساختمان ارايه و در پايان همانروز ميزگرد آسيب شناسي ايمني در كارگاههاي ساختماني برگزار شد. روز دوم نيز ( 20 آبان )، به برگزاري شش كارگاه آموزشي تخصصي در صبح و بعد از ظهر اختصاص يافت.&lt;br /&gt;از نقاط قوت اين همايش مي توان به برگزاري نمايشگاه جانبي آن اشاره نمود كه شركت ها و موسسات ارائه دهنده خدمات ايمني / HSE و توليد كننده وسائل و تجهيزات و شركتهاي بيمه‌گر در آن حضور داشتند.&lt;br /&gt;ابتكاري كه از سوي برگزار كنندگان همايش شاهد آن بوديم، برپايي مانور كار در ارتفاع و عمليات امداد و نجات بود كه توسط يكي از شركتهاي تخصصي در اين زمينه برگزار گرديد و با استقبال حاضران مواجه شد.بيانيه پاياني همايش با كسب نظرات تمام ارائه دهندگان مقالات و شركت كنندگان در همايش در حال تدقيق بوده كه پس از نهايي شدن به اطلاع عموم خواهد رسيد.&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;فهرست مقالات ارائه شده و مشخصات كارگاههاي آموزشي و برنامه هاي همايش را مي توانيد از لينك ذيل دريافت نماييد.&lt;br /&gt;&lt;a href="http://ohsms.meedc.ir/index.php?module=file_manager&amp;amp;func=viewdownload&amp;amp;cid=502#" _fckxhtmljob="1" _fcksavedurl="http://ohsms.meedc.ir/index.php?module=file_manager&amp;amp;func=viewdownload&amp;amp;cid=502#"&gt;دريافت فايل فهرست مقالات&lt;/a&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;با تشكر از آقاي مهندس رياحي&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5297762633202785530?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5297762633202785530/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5297762633202785530&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5297762633202785530'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5297762633202785530'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_15.html' title='دومين همايش ملي ايمني ساختمان'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4337997892565194815</id><published>2010-11-10T18:30:00.000+03:30</published><updated>2010-11-10T18:31:37.153+03:30</updated><title type='text'>بهبود پوشش‌دهی قطعات صنعتی در برابر خوردگی و اکسیداسیون دما بالا</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;span style="font-size:130%;"&gt;محققان دانشگاه رازی کرمانشاه با همکاری پروفسور احمدعلی آماده استاد دانشگاه تهران، با سنتز و به‌کارگیری زیرلایه‌ی نانومتری و آلومینایزینگ آن در دماهای پایین، موفق به کاهش زمان شکل‌گیری ایجاد پوشش‌های مقاوم در برابر خوردگی داغ و اکسیداسیون دما بالای کارکرد قطعاتی همچون پره‌ی توربین‌های گازی شدند.&lt;br /&gt;به نقل از نانو، دکتر علی‌محمد رشیدی، عضو هیئت علمی دانشگاه رازی کرمانشاه، در گفتگو با بخش خبری سایت ستاد ویژه‌ی توسعه‌ی فناوری نانو، گفت: «طبق نتایج تحقیق انجام شده، ایجاد نانوساختار نیکل برای فرایند آلومینایزینگ که فرایندی صنعتی برای ایجاد پوشش‌های مقاوم به اکسیداسیون دمای بالا است، امکان ایجاد پوشش در دماهای به مراتب پایین‌تر از روش‌های مرسوم را فراهم نموده و موجب کاهش زمان تشکیل پوشش‌های آلومینایدی می‌گردد».&lt;br /&gt;در این تحقیق ضمن تهیه‌ی نمونه‌هایی از جنس نیکل نانوساختار و همچنین آلیاژ نانوساختار نیکل- تنگستن به همراه نمونه‌های میکروکریستال، این نمونه‌ها تحت عملیات آلومینایزینگ دمای پایین- اکتیویته‌ی بالا قرار گرفته‌‌اند. بعد از عملیات آلومینایزینگ، ساختار سطح مقطع آنها و چگونگی تغییر ضخامت پوشش ایجاد شده با گذشت زمان در نمونه‌های میکرو و نانوکریستال مقایسه شده‌است.&lt;br /&gt;نتایج به‌دست آمده نشان می‌دهد که با نانو شدن فلز زیرلایه، زمان آغاز شکل‌گیری پوشش آلومینایدی در یک دمای معین مورد بررسی، کوتاه‌تر شده و نوع پوشش نیز از پوشش تک‌لایه به پوشش دولایه (هنگام آلومینایزینگ طولانی مدت) تبدیل شده‌است. اما برخلاف سرعت شکل‌گیری در مراحل اولیه، سرعت رشد (ضخیم شدن) پوشش در پوشش‌های ضخیم در نمونه‌های میکرو و نانوکریستال تفاوت زیادی نداشته و حتی برخلاف انتظار، انرژی سرعت رشد در نمونه‌های نانوکریستال به علت تشکیل پوشش دولایه و تغییر فاز، کمی بیشتر بوده و موجب گردیده اثر نانو شدن اندازه‌ی دانه‌ها در سایه قرار گرفته و کمرنگ گردد.&lt;br /&gt;جزئیات این پژوهش -که با راهنمایی پروفسور احمدعلی آماده انجام شده،- در مجله‌ی Intermetallics (جلد 18، صفحات 1523- 1517، سال 2010) منتشر شده‌است.&lt;br /&gt;نانو &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4337997892565194815?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4337997892565194815/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4337997892565194815&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4337997892565194815'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4337997892565194815'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_520.html' title='بهبود پوشش‌دهی قطعات صنعتی در برابر خوردگی و اکسیداسیون دما بالا'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5504456470236628288</id><published>2010-11-10T18:27:00.000+03:30</published><updated>2010-11-10T18:28:57.817+03:30</updated><title type='text'>ابتکار شرکت توزیع برق مشهد در طراحی و ساخت ابزارهای تخصصی خط گرم</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;span style="font-size:130%;"&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;به ابتکار شرکت توزیع نیروی برق مشهد ابزارهای تخصصی خط گرم به منظور سرویس و نگهداری تجهیزات پستهای زمینی فشار متوسط طراحی و ساخته شد.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;به نقل از روابط عمومی شر کت توزیع نیروی برق مشهد، سید ابوالفضل اشرف زاده مدیرامور خدمات فنی 20 کیلوولت با اعلام این خبر اظهار داشت: این نوع ابزارها برای اولین بار در کشور توسط شرکت توزیع برق مشهد طراحی و ساخته شده است.&lt;br /&gt;وی افزود : این ابتکار با هدف تحقق شعار امسال شرکت توزیع برق مشهد اعمال خاموشی خواسته خدا حافظ انجام شده است.&lt;br /&gt;مهندس احمدی رئیس اداره تعمیرات پستهای هوایی و زمینی شرکت توزیع برق مشهد نیز با اشاره به اینکه در محدوده مشهد بیش از هزار پست 20 کیلوولت وجود دارد و باید در سال 2 نوبت به صورت سرد سرویس دهی و 2 بار به صورت گرم غبار زدایی و نظافت شود، گفت: انجام این عملیات باتوجه به تعداد پستهای مذکور همواره مشکل ساز بوده ضمن اینکه برای چنین کاری به صورت خط گرم هیچگونه الگو و روش و سیستمی در صنعت برق برای پست زمینی وجود نداشته است.&lt;br /&gt;وی از تلاش همکارانش در اداره تعمیرات پستهای زمینی و هوایی و پیگیری آنها برای طراحی و ساخت این ابزارها خبر داد و گفت: با تلاش نیروها و استفاده از اطلاعات اینترنت و تجربیات اساتید خط گرم موفق به ابداع و ساخت ابزارهای تخصصی خط گرم شدیم.&lt;br /&gt;وی تصریح کرد: برای هر آیتم در آچارکشی و سرویس پستها میتوانیم از این ابزارها استفاده کنیم و قرار است پس از انجام تستهای لازم و گذراندن آموزشهای لازم توسط استادان، عملیات آن به نیروها منتقل شود.&lt;br /&gt;وی گفت: پس از تکمیل کار میتوانیم در طول سال، خاموشی ناشی از تعمیرات، سرویس و نگهداری پستها حذف کنیم و حوادث را نیز کاهش دهیم.&lt;br /&gt;گفتنی است این نوع ابزارها ضمن اینکه کاربرد بالای در عملیات خط گرم دارد،ضریب ایمنی و اطمینان آن کاملا تست شده است.&lt;br /&gt;روابط عمومی شر کت توزیع نیروی برق مشهد &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5504456470236628288?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5504456470236628288/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5504456470236628288&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5504456470236628288'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5504456470236628288'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_10.html' title='ابتکار شرکت توزیع برق مشهد در طراحی و ساخت ابزارهای تخصصی خط گرم'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-860453787702534816</id><published>2010-11-10T18:25:00.001+03:30</published><updated>2010-11-10T18:27:45.811+03:30</updated><title type='text'>پیشگیری از حادثه با SMS هشدار! سامانه کنترل و هشدار تلفنی دما و برق در کشور ساخته شد</title><content type='html'>&lt;a href="http://www.sabainfo.ir/showimage.aspx?imagepath=/content/media//image/2010/10/32976_orig.jpg&amp;amp;mode=150"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 150px; CURSOR: hand; HEIGHT: 131px; TEXT-ALIGN: center" alt="" src="http://www.sabainfo.ir/showimage.aspx?imagepath=/content/media//image/2010/10/32976_orig.jpg&amp;amp;mode=150" border="0" /&gt;&lt;/a&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;&lt;span style="font-size:130%;"&gt;محققان سمنانی موفق به ساخت دستگاه اعلام کننده و هشدار دهنده دما و برق با استفاده از سامانه پیامک تلفن همراه (SMS) شد.&lt;/span&gt; &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;به نقل از ایسنا، مهندس حامد جهانشاهی، دانش‌آموخته رشته مکانیک دانشگاه سمنان که با همکاری محسن صابریان فارغ التحصیل رشته الکترونیک دانشگاه سمنان موفق به ساخت این سامانه شده اظهار کرد: این دستگاه یک سیستم اعلام کننده هشدار دهنده دما و برق بوده و بر روی هر دستگاه یا محیطی که کنترل دما و یا قطع و وصل شدن برق در آن اهمیت دارد، قابل نصب و بهره‌برداری است.&lt;br /&gt;وی تصریح کرد: در این سیستم، مانیتورینگ دما و جریان برق با بهره‌گیری از شبکه مخابراتی موجود در کشور انجام می‌شود و نحوه عملکرد کلی آن به این صورت است که بر روی دستگاه یک عدد سیم کارت تلفن همراه نصب می‌شد، سپس دستگاه دما و وضعیت جریان برق را در ساعاتی که بر روی دستگاه تنظیم شده به صورت پیامک (SMS) به تلفن همراه کاربر یا کاربران ارسال می‌کند و در صورتی که مقدار دما از محدوده دمایی تنظیم شده، افزایش و یا کاهش پیدا کرده و یا جریان برق قطع و یا وصل شود؛ این دستگاه با ارسال پیامک‌های پیاپی (پیامک آلارم) به تلفن همراه کاربر یا کاربران، شرایط تغییر یافته را اعلام می‌کند.&lt;br /&gt;جهانشاهی تصریح کرد: این دستگاه به جز مقدار دما و وضعیت برق،‌ پارامترهای دیگری همچون باز یا بسته بودن در، ماکزیمم و مینیمم دما در 24 ساعت گذشته، ساعت اندازه‌گیری دما، مقدار شارژ باقیمانده سیم کارت اعتباری نصب شده بر روی دستگاه و موارد مشابه را نیز کنترل کرده و از طریق پیامک به کاربر یا کاربران اطلاع می‌دهد.&lt;br /&gt;به گفته وی بر روی تمام مدل‌ها یک سیم کارت تلفن همراه، یک آداپتور تغذیه و یک یا دو سنسور دما نصب می شود.&lt;br /&gt;مدیرعامل شرکت مهندسی پویان صنعت قومس خاطرنشان کرد: به طور کلی این دستگاه می‌تواند دو نوع پیامک شامل «پیامک گزارش» و «پیامک آلارم» به تلفن همراه کاربر یا کاربران ارسال کند. پیامک گزارش حاوی میزان دمای محیط، زمان اندازه‌گیری دما، وضعیت باز یا بسته بودن در، قطع و یا وصل بودن برق، ماکزیمم و مینیمم دما در 24 ساعت گذشته، میزان شارژ سیم کارت اعتباری و تاریخ انقضای اعتبار سیم کارت اعتباری بوده و در ساعاتی از شبانه روز که بر روی دستگاه تنظیم شده به تلفن همراه کاربر یا کاربران ارسال می کند.&lt;br /&gt;وی ادامه داد: پیامک آلارم فقط زمانی به تلفن همراه کاربر یا کاربران ارسال می‌شود که یکی از این موارد شامل خروج میزان دما از حد مجاز تنظیم شده، قطع یا وصل شدن برق، آسیب دیدن و یا قطع شدن سنسور دما، باز ماندن درب در محیط رخ داده باشد که در این حالت پیامک‌های هشدار تا حداکثر شش نوبت و در فاصله‌های زمانی تنظیم شده بر روی دستگاه ارسال می‌شود.&lt;br /&gt;ایسنا &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-860453787702534816?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/860453787702534816/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=860453787702534816&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/860453787702534816'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/860453787702534816'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/sms.html' title='پیشگیری از حادثه با SMS هشدار! سامانه کنترل و هشدار تلفنی دما و برق در کشور ساخته شد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1859885587095483308</id><published>2010-11-09T08:49:00.006+03:30</published><updated>2011-08-21T01:30:57.929+04:30</updated><title type='text'>تعويض تراورس به روش خط گرم فرمان از نزديك ( لمس مدار ) HOT LINE</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=207&amp;amp;viewkey="&gt;&lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 344px; DISPLAY: block; HEIGHT: 254px; CURSOR: hand" border="0" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=207&amp;amp;viewkey=" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;قبلا براي تعويض تراورس و مقره ها روي شبكه هاي هوايي برق مجبور بوديم شبكه برق منطقه را براي مدتي قطع كنيم كه در اين بين بسياري از منازل و واحدهاي تجاري و صنعتي بي برق مي شدند كه پيامدهاي متعددي از جمله نارضايتي مردم را در پي داشت.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;color:#ffff00;"&gt;&lt;strong&gt;مدتي است كه شركت توزيع نيروي برق شهرستان مشهد با استفاده از نيروهاي آموزش ديده و با استفاده از تكنولوژي هاي روز دنيا بدون اعمال خاموشي اين تعميرات را بر روي شبكه هاي برق در شرايط كاملاً ايمن انجام مي دهد.&lt;/strong&gt;&lt;/span&gt; &lt;img style="TEXT-ALIGN: center; MARGIN: 0px auto 10px; WIDTH: 339px; DISPLAY: block; HEIGHT: 230px; CURSOR: hand" border="0" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=204&amp;amp;viewkey=" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1859885587095483308?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1859885587095483308/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1859885587095483308&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1859885587095483308'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1859885587095483308'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/hot-line_09.html' title='تعويض تراورس به روش خط گرم فرمان از نزديك ( لمس مدار ) HOT LINE'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3534252512898410935</id><published>2010-11-09T08:49:00.002+03:30</published><updated>2010-11-09T08:58:06.004+03:30</updated><title type='text'>آئين نامه ايمني كار در ارتفاع درجلسه مورخ 10/8/89  شورايعالي حفاظت فني تصويب شد.</title><content type='html'>&lt;a href="http://www.irimlsa.ir/FixInfo/bazresikar/pages/pic-1/DSC01145.JPG"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 315px; CURSOR: hand; HEIGHT: 196px; TEXT-ALIGN: center" alt="" src="http://www.irimlsa.ir/FixInfo/bazresikar/pages/pic-1/DSC01145.JPG" border="0" /&gt;&lt;/a&gt;&lt;a name="OLE_LINK3"&gt;&lt;span style="font-size:130%;"&gt;هشتادو سومين جلسه شورايعالي حفاظت فني به رياست آقاي مهندس نظري جلالي معاونت محترم روابط كار &lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;برگزار شد و آئين نامه ايمني كار در ارتفاع مورد تصويب قرار گرفت در اين آئين نامه با توجه به روند رو به رشد و توسعه روز افزون فعاليت هاي اقتصادي اعم از توليدي، صنعتي ، خدماتي، كشاورزي، معدني و ساختماني و فرآيندهاي مرتبط با آن بويژه در جهت ساخت ، تكميل نوسازي و بازسازي انواع سازه ها ،تجهيزات ، دستگاه ها و خدمات در كليه فعاليت هاي ذكر شده نياز به انجام كار و عمليات در ارتفاع بوده و اين مهم بدليل ماهيت آن مي بايستي به انواع ابزار آلات، تجهيزات و دستگاه ها مناسب و كارا مانند نردبان ها ، داربست ها ، كار با طناب، دستگاه هاي بالابر و ... صورت مي گيرد از طرف ديگر با توجه به ماهيت خطرناك انجام كار در ارتفاع و يا بعبارتي ديگر وجود ريسك بالاي خطر در اين نوع فعاليت بويژه در مواجهه با تجهيزات و دستگاههاي ذكر شده حوادث با ضرايب و فور و شدت بالايي را شاهد هستيم كه بدليل نبود مقررات و قوانين كافي، يا آيين نامه تخصصي و نيز در جهت حفظ و صيانت از منابع انساني و مادي ، ايجاد شرايط ايمني كافي در محيط كار و رعايت اصول صحيح انجام كار و پيشگيري از حوادث ناشي ازكار لزوم تدوين «آيين نامه ايمني كار در ارتفاع» بيش از پيش احساس مي گرديد.&lt;br /&gt;كه با استفاده از نظرات كارشناسان و مجريان و مطالعه و بررسي استانداردها مرتبط و كسب نظرات ادارات كل كار و امور اجتماعي استانها ، مركز تحقيقات و تعليمات حفاظت بهداشت كار، شركت ها و سازمانهاي مربوطه و بررسي در كميته هاي تخصصي و عمومي و اخذ نظرات امور حقوقي و اعضاي شورا با طرح در سه جلسه شورايعالي حفاظت فني اين ايين نامه در 8 فصل و 135 ماده و 3 تبصره مورد تصويب قرار گرفت.&lt;br /&gt;در آن كليات وتعاريف ، الزامات عمومي، نردبان ، جايگاه كار، داربست، روش دسترسي با طناب، سامانه هاي متوقف كننده سقوط، تور ايمني و بالابرهاي سيار مطرح شده است كه اميد است با تصويب نهايي توسط وزير محترم كار و امور اجتماعي و اجرايي شدن آن گام ديگري در جهت حذف و كاهش حوادث ناشي از كار در كارگاهها و فعاليت هاي مرتبط ونهايتاً صيانت نيروي انساني ومنابع مادي كشور برداشته شود.&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3534252512898410935?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3534252512898410935/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3534252512898410935&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3534252512898410935'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3534252512898410935'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/10889.html' title='آئين نامه ايمني كار در ارتفاع درجلسه مورخ 10/8/89  شورايعالي حفاظت فني تصويب شد.'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1946933269625443496</id><published>2010-11-09T08:45:00.000+03:30</published><updated>2010-11-09T08:46:35.285+03:30</updated><title type='text'>داستان مدیریتی : نبوغ</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;در يك شركت بزرگ كه توليد وسايل آرايشي را برعهده داشت ، يك مورد بياد ماندني اتفاق افتاد : شكايتي از سوي يكي مشتريان به كمپاني رسيد . او اظهار داشته بود كه هنگام خريد يك بسته صابون متوجه شده بود كه آن قوطي خالي است. بلافاصله با تاكيد و پيگيريهاي مديريت ارشد كارخانه اين مشكل بررسي، و دستور صادر شد كه خط بسته بندي اصلاح گردد و قسمت فني و مهندسي نيز تدابير لازمه را جهت پيشگيري از تكرار چنين مسئله اي اتخاذ نمايد . مهندسين نيز دست به كار شده و راه حل پيشنهادي خود را چنين ارائه دادند : )پايش ( مونيتورينگ ) خط بسته بندي با اشعه ايكس (بزودي سيستم مذكور خريداري شده و با تلاش شبانه روزي گروه مهندسين ،‌ دستگاه توليد اشعه ايكس و مانيتورهائي با رزولوشن بالا نصب شده و خط مذبور تجهيز گرديد . سپس دو نفر اپراتور نيز جهت كنترل دائمي پشت آن دستگاهها به كار گمارده شدند تا از عبور احتمالي قوطيهاي خالي جلوگيري نمايند. نكته جالب توجه در اين بود كه درست همزمان با اين ماجرا ، مشكلي مشابه نيز در يكي از كارگاههاي كوچك توليدي پيش آمده بود اما آنجا يك كارمند معمولي و غير متخصص آنرا به شيوه اي بسيار ساده تر و كم خرجتر حل كرد : (تعبيه يك دستگاه پنكه در مسير خط بسته بندي تا قوطی خالی را باد ببرد !!! )&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1946933269625443496?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1946933269625443496/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1946933269625443496&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1946933269625443496'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1946933269625443496'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_09.html' title='داستان مدیریتی : نبوغ'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3578651933479027446</id><published>2010-11-03T07:21:00.001+03:30</published><updated>2010-11-03T09:03:54.025+03:30</updated><title type='text'>آيين‌نامه سيستم اتصال به زمين (ارتينگ)</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;p align="right"&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;آيين‌نامه سيستم اتصال به زمين (ارتينگ)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;فصل اول ـ تعاريف&lt;br /&gt;اين فصل به تعريف اصطلاح ها و كلمه‌هاي بكار رفته در آئين‌نامه مي‌پردازد.&lt;br /&gt;1ـ زمين (ارت)1:&lt;br /&gt;رسانندگي جرم زمين را در صورتي كه پتانسيل الكتريكي در هر نقطه از زمين به صورت قراردادي برابر صفر در نظر گرفته شود، زمين (ارت) مي‌نامند.&lt;br /&gt;2ـ سيستم اتصال به زمين (ارتينگ)2:&lt;br /&gt;يك يا چند الكترود همراه با سيمهاي ارت را كه قابليت اتصال به ترمينال اصلي داشته باشند، سيستم اتصال به زمين (ارتينگ) مي‌نامند.&lt;br /&gt;3ـ الكترود ارت (زمين)3:&lt;br /&gt;رسانا يا گروهي از رساناهاي متصل به هم است كه اتصال الكتريكي به زمين را فراهم مي‌كنند.&lt;br /&gt;4ـ مقاومت الكترود ارت4:&lt;br /&gt;مقاومت بين ترمينال اصلي زمين و كره زمين است.&lt;br /&gt;5 ـ امپدانس حلقه اتصال به زمين5 :&lt;br /&gt;امپدانس حلقه جريان اتصالي زمين است كه شروع و پايان آن نقطه اتصالي است و با ZS نشان داده مي‌شود.&lt;br /&gt;ـ حلقه اتصالي زمين در سيستمهاي مختلف به شرح ذيل است:&lt;br /&gt;الف ـ سيستمهاي TN&lt;br /&gt;نقطه شروع (محل اتصالي)، از بدنه دستگاه به ترتيب به سيم ارت، شينه ارت، شينه نول، نقطه ترانس، سيم‌پيچ ترانس، سيم فاز اتصالي و نقطه اتصال به بدنه.&lt;br /&gt;ب ـ سيستمهاي TT و IT&lt;br /&gt;نقطه شروع (محل اتصالي)، سيم اتصال به زمين، الكترود زمين، زمين، الكترود سيستم، شينه نول، نقطه صفر ترانس، سيم فاز اتصالي و نقطه اتصالي.&lt;br /&gt;6 ـ اتصالي:&lt;br /&gt;حالتي از مدار است كه جريان در مسيري غيرعادي يا بدون اينكه پيش‌بيني شده باشد يا در نظر گرفته شود، جاري مي‌شود. اين جريان امكان دارد از نقص در عايق‌بندي يا از بستهاي به كار رفته بر روي عايق رساناها ناشي شود.&lt;br /&gt;7 ـ جريان اتصال به زمين (جريان اتصال كوتاه)6 :&lt;br /&gt;اضافه جرياني است كه در نتيجه بروز اتصالي با امپدانسي قابل چشم‌پوشي بين هاديهاي با پتانسيلهاي مختلف در شرايط عادي كار برقرار شود.&lt;br /&gt;8 ـ جريان نشتي زمين7 :&lt;br /&gt;جريان جاري به زمين يا رساناهاي ديگري را كه مدار الكتريكي آنها به زمين راه دارد، جريان نشتي زمين مي‌نامند. در صورت استفاده از خازن در مدارها، امكان دارد جريان مذكور داراي مقدار جزء خازني هم باشد.&lt;br /&gt;9ـ سيم اتصال به زمين (سيم ارت)8 :&lt;br /&gt;سيم حفاظتي را گويند كه ترمينال اصلي ارت تأسيسات را به الكترود ارت يا ساير قسمتهاي اتصال به زمين وصل مي‌كند.&lt;/p&gt;&lt;p align="right"&gt;بقيه آيين نامه را در لينك ذيل ملاحظه فرماييد :&lt;br /&gt;&lt;a href="http://ohsms.meedc.ir/index.php?module=content&amp;amp;func=viewpage&amp;amp;pageid=792&amp;amp;ok=1"&gt;http://ohsms.meedc.ir/index.php?module=content&amp;amp;func=viewpage&amp;amp;pageid=792&amp;amp;ok=1&lt;/a&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3578651933479027446?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3578651933479027446/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3578651933479027446&amp;isPopup=true' title='1 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3578651933479027446'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3578651933479027446'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_03.html' title='آيين‌نامه سيستم اتصال به زمين (ارتينگ)'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5810545826403116513</id><published>2010-11-01T12:54:00.003+03:30</published><updated>2010-11-01T12:58:55.669+03:30</updated><title type='text'>اسلايدهاي حوادث ترافيكي كودكان</title><content type='html'>&lt;span style="font-size:130%;"&gt;&lt;strong&gt;با تشكر از همكاران عزيزم در مركز بهداشت شهداي انقلاب شهرستان شيراز كه اين اسلايدهاي ارزشمند را تهيه نمودند :&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca1.pdf" target="_blank"&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;آموزش ترافیکی کودکان1 &lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;br /&gt;&lt;a href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca2.pdf" target="_blank"&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="color:#ffff00;"&gt;آموزش ترافیکی کودکان2&lt;/span&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;a title="" href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca2.pdf" target="_blank"&gt;&lt;/a&gt;&lt;br /&gt;&lt;a href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca3.pdf" target="_blank"&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;آموزش ترافیکی کودکان3 &lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;a title="" href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca3.pdf" target="_blank"&gt;&lt;/a&gt;&lt;br /&gt;&lt;a href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca4.pdf" target="_blank"&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="color:#ffff00;"&gt;آموزش ترافیکی کودکان4&lt;/span&gt; &lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;a title="" href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca4.pdf" target="_blank"&gt;&lt;/a&gt;&lt;br /&gt;&lt;a href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca5.pdf" target="_blank"&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;آموزش ترافیکی کودکان5 &lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;a title="" href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/ca5.pdf" target="_blank"&gt;&lt;/a&gt;&lt;br /&gt;&lt;a href="http://shce.sums.ac.ir/icarusplus/export/sites/shce/download/bicycle_safety.pdf" target="_blank"&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#ffff00;"&gt;رفتار و فرهنگ ترافیک&lt;/span&gt;&lt;/strong&gt; &lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5810545826403116513?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5810545826403116513/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5810545826403116513&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5810545826403116513'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5810545826403116513'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_7881.html' title='اسلايدهاي حوادث ترافيكي كودكان'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6743363734319724918</id><published>2010-11-01T12:50:00.001+03:30</published><updated>2010-11-01T12:51:51.126+03:30</updated><title type='text'>چهل اصل شادی بخش</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;span style="font-size:130%;"&gt;۱- شادی خود را به هیچ چیز و هیچ کس وابسته نکن تا همیشه از آن برخوردار باشی .&lt;br /&gt;۲- انتظار نداشته باش همیشه آن چه در اطرافت اتفاق می افتد مطابق میل و خواسته ات باشد .&lt;br /&gt;۳- هنگام عصبانیت هیچ تصمیمی نگیر .&lt;br /&gt;۴- از سختی ها و مشکلات زندگی استقبال کن و با غلبه بر آن ها به خود پاداش بده .&lt;br /&gt;۵- اجازه نده اتفاقات ناخوشایند روحیه ات را خراب کند .&lt;br /&gt;۶- با بحث های بی نتیجه انرژی خود را هدر نده .&lt;br /&gt;۷- انتظار نداشته باش با منفی نگری جسمی سالم داشته باشی .&lt;br /&gt;۸- از هیچ کس و هیچ چیز توقع نداشته باشد .&lt;br /&gt;۹- تا با خود مهربان نباشی ، نمی توانی مهر بورزی .&lt;br /&gt;۱۰- قبل از مطمئن شدن ، در مورد هیچ چیز قضاوت نکن .&lt;br /&gt;۱۱- به تفسیر و تعبیر کارهای دیگران نپرداز .&lt;br /&gt;۱۲- هر کاری را با علاقه و تمرکز انجام بده .&lt;br /&gt;۱۳- زندگی خود را هدفمند کن و برای رسیدن به اهدافت تلاش کن .&lt;br /&gt;۱۴- چیزهایی را که دوست داری به دیگران ببخش .&lt;br /&gt;۱۵- قلبت را از نفرت خالی کن تا خوشبختی در آن لانه کند .&lt;br /&gt;۱۶- برای انجام کارهای مورد علاقه ات زیاد به نظرات دیگران اهمیت نده .&lt;br /&gt;۱۷- در تصمیم های خود تأخیر نینداز .&lt;br /&gt;۱۸- هنگام عصبانیت نفس عمیق بکش و تا ده بشمار .&lt;br /&gt;۱۹- با دیگران طوری رفتار کن که دوست داری با خودت رفتار شود .&lt;br /&gt;۲۰- به هیچ کس امید نداشته باش به جز خدا .&lt;br /&gt;۲۱- بر جسم و روح خود مسلط شو .&lt;br /&gt;۲۲- برای این که شاد باشی باید شادی آفرین باشی .&lt;br /&gt;۲۳- در زندگی به جای « شناور بودن » ، « شناگر » باش .&lt;br /&gt;۲۴- اندوه روز نیامده را ، بر روز آمده ات نیفزا .&lt;br /&gt;۲۵- هرگز سعی نکن به دیگران بقبولا نی که حرفت درست است .&lt;br /&gt;۲۶- قبل از انجام کاری یا گفتن چیزی به ضرورت آن بیندیش .&lt;br /&gt;۲۷- بی احترامی دیگران را با بی اعتنایی جواب ده .&lt;br /&gt;۲۸- به جای بیزاری از انسان ها از رفتار های بد آن ها متنفر باش .&lt;br /&gt;۲۹- بگذار دیگران از تو به عنوان فردی آرام و خوشرو یاد کنند .&lt;br /&gt;۳۰- یگانه داروی آرام بخش روح و جان ، یاد خداست .&lt;br /&gt;۳۱- خود را از اسارت زنجیرهای بد بینی ، منفی نگری و ناامیدی آزاد کن .&lt;br /&gt;۳۲- به خاطر اشتباهات گذشته خود را سرزنش نکن .&lt;br /&gt;۳۳- به دیگران کمک کن آنچه را که می خواهند به دست آورند .&lt;br /&gt;۳۴- در فرهنگ لغات خود « شکست » را « تجربه » معنا کن .&lt;br /&gt;۳۵- با شرایط زندگی سازگار باش .&lt;br /&gt;۳۶- هنگام از دست دادن ناراحت نشو ، وقتی هم چیزی را به دست آوردی خوشحال نباش .&lt;br /&gt;۳۷- درمقابل خواسته ها و گفتار دیگران انعطاف پذیر باش و نخواه که حرف ، حرف خودت باشد.&lt;br /&gt;۳۸- برای کشف حقایق ، زیاد تفکر کن ، به خصوص جهان آفرینش .&lt;br /&gt;۳۹- به قدر توان تلاش کن و نتیجه را به خدا واگذار کن .&lt;br /&gt;۴۰- هرگز خودت را با دیگران مقایسه نکن .&lt;br /&gt;چرا که تو چیزهایی داری که دیگران در حسرت آن ها هستند .&lt;br /&gt;منبع : ماهنامه موفقیت شماره 64 « علیرضا شاهرودیان » &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6743363734319724918?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6743363734319724918/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6743363734319724918&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6743363734319724918'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6743363734319724918'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_2963.html' title='چهل اصل شادی بخش'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8019586976795605206</id><published>2010-11-01T11:29:00.001+03:30</published><updated>2010-11-01T11:31:22.855+03:30</updated><title type='text'>سياست‌هاي ملي ارتقاء عادلانه ايمني كودكان تدوين شود</title><content type='html'>&lt;a href="http://media.farsnews.com/Media/8906/Images/jpg/A0906/A0906395.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 250px; CURSOR: hand; HEIGHT: 150px; TEXT-ALIGN: center" alt="" src="http://media.farsnews.com/Media/8906/Images/jpg/A0906/A0906395.jpg" border="0" /&gt;&lt;/a&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;خبرگزاري فارس: شهردار تهران در پيامي به مناسبت روز جهاني كودك، تصريح كرد: اكنون بايد سياست‌هاي ملي ارتقاء عادلانه ايمني كودكان تدوين شود و برنامه عملياتي مورد نياز براي تحقق اين مهم در سطح كشور طراحي و اجرا شود.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;به گزارش خبرگزاري فارس، متن كامل اين پيام به شرح زير است:&lt;br /&gt;بر اساس آخرين آمار وزارت بهداشت، دومين علت مرگ كودكان 1 تا 59 ماهه كشورمان، حوادث و سوانح غير عمدي است كه شايد تاكنون كمتر به آن توجه كرده باشيم. همچنين حوادث ترافيكي و غرق شدن در آب از شايع‌ترين علل حوادث و سوانح غير عمدي منتهي به مرگ كودكان 1 تا 59 ماهه كشورمان هستند. البته به اين رقم بايد آمار بيماري و ناتواني حاصل از آسيب را هم افزود.&lt;br /&gt;آسيب‌هاي كودكان اجتناب ناپذير نيستند و مي‌توان از وقوع آن‌ها پيشگيري كرد و كنترل شان كرد و واقعيت اين است كه تمام افراد بشر به ويژه كودكان از حق برابر براي داشتن ايمني و سلامت برخوردار هستند.&lt;br /&gt;در ساليان اخير با استفاده از الگوي جهاني جامعه ايمن در 17 منطقه از شهر تهران اقدامات مشاركتي بخشي و بين بخشي براي ارتقاي عادلانه ايمني تمامي شهروندان و محلات شهرمان آغاز شده است كه تا كنون به عضويت مناطق 21،20،10،5،4و22 كلانشهر تهران در شبكه جهاني جوامع ايمن منتهي شده است و مي تواند به الگويي ملي براي ارتقاء عادلانه ايمني تمامي اقشار جامعه به ويژه كودكان كشورمان تبديل شود.&lt;br /&gt;اكنون بايد سياست‌هاي ملي ارتقاء عادلانه ايمني كودكان تدوين شود و برنامه عملياتي مورد نياز در سطح كشور طراحي و اجرا شود كه به اين منظور نيز كميته ارتقاء عادلانه و اهداف ملي ايمني كودكان در شهرداري منطقه 3 تهران تأسيس شده است تا با مشاركت تمامي نهادهاي دولتي و غير دولتي ، مبتكران واساتيد حوزه ودانشگاه به تعيين اولويت‌ها و اهداف ايمني كودكان و تعيين مدل‌هاي عملياتي براي تحقق اهداف مذكور بپردازد.&lt;br /&gt;در واقع تا ارتقاء عادلانه ايمني تمامي كودكان كشور راه درازي در پيش است و در اين راه اقدامات زير ضروري است :&lt;br /&gt;1- پيشگيري از حوادث و آسيب‌هاي كودكان بايد به عنوان اولويت ملي و بخشي از برنامه مراقبت بهداشتي اوليه و حفظ حيات كودكان كشور باشد.&lt;br /&gt;2- تدوين سياست‌هاي حفظ و ارتقاي ايمني همگاني و بازنگري خدمات و محصولات كاهنده ايمني بويژه مضر براي كودكان بايد توسط مراكز علمي،تحقيقاتي و دانشگاهي، موسسات و شركت‌هاي دولتي وغير دولتي صورت پذيرد.&lt;br /&gt;3- تجارب جهاني حاكي از موفقيت برنامه‌هاي پيشگيري از آسيب‌ها و حوادث تهديد كننده در بين كودكان است، كه براي موفقيت هرچه بيشتر در كشورمان برنامه ريزي و مشاركت موثر شهروندان و همكاري سازمانها و مراكز دولتي و غير دولتي در برنامه‌هاي جامعه ايمن را مي‌طلبد.&lt;br /&gt;4- سياست ملي ارتقاء عادلانه ايمني در كشور بايد به همه اقشار در معرض خطر به ويژه كودكان بپردازد كه اين مهم با همكاري همه ارگان‌هاي ذي‌ربط از جمله شهرداري، آموزش و پرورش، بهداشت وعلوم پزشكي، تربيت بدني، دانشگاه‌ها، استاندارد، هلال احمر، بهزيستي، پليس و ساير سازمان‌هاي دولتي وغير دولتي امكان‌پذير خواهد بود.&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8019586976795605206?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8019586976795605206/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8019586976795605206&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8019586976795605206'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8019586976795605206'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post_01.html' title='سياست‌هاي ملي ارتقاء عادلانه ايمني كودكان تدوين شود'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3791358860165117108</id><published>2010-11-01T07:00:00.000+03:30</published><updated>2010-11-01T07:05:20.591+03:30</updated><title type='text'>افراد مؤثر</title><content type='html'>&lt;span style="font-size:130%;"&gt;1- پنج نفر از ثروتمندترين افراد دنيا را نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;2- آخرين پنج برنده جايزه مسابقه \\\"Heisman&lt;/a&gt; trophy\\\" را نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;3- ده برنده جايزه نوبل را نام ببريد.4- آخرين دوازده نفر برنده آکادميک بهترين بازيگر را نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;5- آخرين برنده بهترين سريال دنيا را نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;چطور جواب داديد؟&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;نکته اين است که هيچ کس از ما نويسندگان سرمقاله روزنامه ديروز را بخاطر نمي آورد. اينها اشخاص مؤثري در رسيدن به اهداف ما نيستند. آنها در زمينه خودشان بهترين هستند. اما تشويقي وجود ندارد. جايزه ها کم رنگ مي شوند. دست يابي ها فراموش مي شوند. مدارک اعطايي به وسيله صاحبان آن سوزانده مي شوند.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;حالا يک آزمايش ديگر، ببينيد که اينها را چگونه جواب خواهيد داد:&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;1- چند نفر از معلمين خود را که شما را در مدرسه کمک کردند نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;2- سه نفر از دوستان خود را که در مشکلات شما را ياري رساندند نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;3- پنج نفر که به شما چيز با ارزشي را ياد دادند نام ببريد.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;4- به چند نفر فکر کنيد که در شما احساس شکر گزاري خاصي پديد آوردند.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;5-&lt;/span&gt;&lt;span style="font-size:130%;"&gt; به چند نفر فکر کنيد که با آنها وقت گذراندن براي شما لذت بخش است.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;نتيجه گيري:کساني که در زندگي شما تاثير گذار بودند، کساني نيستند که بالاترين مدرک را دارا هستند. بيشترين ثروت، يا بيشترين جوائز...آنها بطور ساده کساني هستند که بيشترين مواظبت را انجام مي دهند.&lt;/span&gt;&lt;br /&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3791358860165117108?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3791358860165117108/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3791358860165117108&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3791358860165117108'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3791358860165117108'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/11/blog-post.html' title='افراد مؤثر'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1228133560151769876</id><published>2010-10-30T16:30:00.002+03:30</published><updated>2010-10-30T16:36:21.940+03:30</updated><title type='text'>پیشرفته ترین سیستم اتوماسیون هوشمند مدیریت ایمنی کار با ماشین آلات صنعتی</title><content type='html'>&lt;a href="http://crtosh.irimlsa.ir/files/attach/mesryan.JPG"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 339px; CURSOR: hand; HEIGHT: 217px; TEXT-ALIGN: center" alt="" src="http://crtosh.irimlsa.ir/files/attach/mesryan.JPG" border="0" /&gt;&lt;/a&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;برای اولین بار در کشور پیشرفته ترین سیستم اتوماسیون هوشمند مدیریت ایمنی کار با ماشین آلات صنعتی، در مرکز تحقیقات و تعلیمات حفاظت فنی و بهداشت کار وزارت کار و امور اجتماعی نصب و راه اندازی گردید.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;رئیس مرکز تحقیقات و تعلیمات حفاظت فنی و بهداشت کار گفت: با نصب و راه&amp;shy;اندازی سامانه هوشمند کنترل ایمنی و نظارت سه بعدی پیشرفته (Safety Eye) در نمایشگاه و فرهنگسرای دایمی ایمنی و بهداشت کار مرکز تحقیقات و تعلیمات حفاظت فنی و بهداشت کار، افق جدیدی در بهبود سیستم مدیریت ایمنی کار برای سالم&amp;shy;سازی محیط&amp;shy;های کار و بکارگیری سیستم&amp;shy;های مدرن و اتوماسیون ایمنی در سطح صنایع کشورگشوده شد.&lt;br /&gt;مهندس مصریان افزود، امروزه متناسب بودن سیستم&amp;shy;های کنترل و ایمنی کار با ماشین&amp;shy;آلات صنعتی موجود در صنایع کشور، به منظور حفظ سلامت و ایمنی کاربران و کارگران با حداقل زمان از دست رفته و کاهشهزینه&amp;shy;های ناشی از توقف دستگاه و عملیات تولید، بخش مهمی از مباحث مربوط به مدیریت ایمنی، افزایش راندمان تولید و بهره&amp;shy;وری نیروی کار در صنایع کشور را به خود اختصاص داده است.وی تصریح کرد، پیش از این، علیرغم وضعیت بسیار نگران&amp;shy;کننده&amp;shy;ای که در تأمین ایمنی محیط&amp;shy;های کاری وجود داشت برای حفاظت از یک محدوده خطرناک، به تعداد زیادی از مجموعه کلیدهای قطع اضطراری(Emergency- Stop)، پرده&amp;shy;های ایمنی(Light curtain) و حسگرهای مختلف نیاز بود، که در صورت ورود کاربر به محدوده خطر، اقدام به قطع و توقف کار دستگاه می&amp;shy;نمود لیکن با بکارگیری سامانه دوربین سه بعدی ایمنی، با ایجاد یک منطقه حفاظت شده سه بعدی با انعطاف&amp;shy;پذیری بالا و قابل برنامه&amp;shy;ریزی، تمام دستگاه&amp;shy;ها و اشیاء در محدوده تحت پوشش ماشین&amp;shy;آلات تولیدی کارگاه&amp;shy;ها و بنگاه&amp;shy;های اقتصادی به شکل سه بعدی مشخص شده و امکان کنترل سرعت و حرکت دستگاه متناسب با خطرات در هر قسمت بوجود خواهد آمد. از دیگر قابلیت&amp;shy;های ارزشمند این سامانه، عدم امکان دستکاری و حذف سیستم&amp;shy;های کنترل ایمنی در دستگاه&amp;shy;ها و خطوط تولیدمی&amp;shy;باشد که این عامل از بروز حوادث تلخ ناشی از غیر فعال نمودن تجهیزات ایمنی در عملکرد ماشین&amp;shy;آلات پیشگیری نموده و بدین ترتیب ترس از آینده&amp;shy;ای نامعلوم که زائیده و معلول حوادث و سوانح دلخراش در محیط کار می&amp;shy;باشد در جامعه صنعتی ما رخت برخواهد بست.مصریان متذکر شد با وجود تمام مزایا و منافعی که گسترش و توسعه صنعت برای بشر بدنبال داشته است سر منشاء خطرات و آبستن حوادث مختلفی نیز بوده که آمار نگران&amp;shy;کننده و بعضاً دلخراش حوادث کوچک و بزرگ که در هر لحظه در جای جای این میهن پهناور رخ می&amp;shy;دهد بیان&amp;shy;کننده همین امر است لذا با افزایش سرعت کار و حجم تولید، همزمان با ورود روبات ها و ماشین&amp;shy;آلات جدید به صنایع و بنگاه&amp;shy;های اقتصادی کشور، لزوم هماهنگی هر چه بیشتر سیستم&amp;shy;های ایمنی و کنترل متناسب با محیط&amp;shy;های صنعتی و دستگاه&amp;shy;های پیچیده خطوط تولید و مونتاژ، چند برابر شده است. با این سیستم کنترل هوشمند، امکان برنامه&amp;shy;ریزی و تجزیه و تحلیل مخاطرات شغلی، ارزیابی شرایط کمک&amp;shy;کننده در بروز حوادث برای کاهش سرعت، اعلام خطر یا توقف دستگاه تا زمانی که دست یا بدن کارگر در محدوده خطر است وجود دارد و از این طریق از قطع بی مورد کل سیستم و عملیات تولید و ایجاد وقفه&amp;shy;های طولانی برای برقراری مجدد کار دستگاه جلوگیری به عمل می&amp;shy;آید.رئیس مرکز تحقیقات وزارت کار و امور اجتماعی در بخش دیگری از سخنان خود، در مورد مزایای این سیستم هوشمند گفت: با استفاده از این تکنولوژی نوین ، امکان دریافت تعداد 4000 ورودی حسگر از 200 دستگاه، حجم زیادی از اطلاعات جمع&amp;shy;آوری و دریافت شده و توسط کابل فیبر نوری به سامانه پردازشگر مرکزی که از رایانه&amp;shy;ای با قابلیت محاسبات فوق سریع می&amp;shy;باشد منتقل شده و توسط سیستم کنترل قابل برنامه&amp;shy;ریزی با تقسیم&amp;shy;بندی محدوده تحت پوشش به مناطق سبز(محدوده کاری)، زرد(منطقه هشدار) و قرمز(منطقه خطر) دستورات اختصاصی برای عملکرد هر دستگاه فرستاده می&amp;shy;شود و با کنترل عملیات هر دستگاه، ایمنی متناسب آن را براساس الزامات استانداردهای جهانی به صورت هوشمند و برنامه&amp;shy;ریزی شده تأمین می&amp;shy;نماید.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1228133560151769876?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1228133560151769876/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1228133560151769876&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1228133560151769876'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1228133560151769876'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_918.html' title='پیشرفته ترین سیستم اتوماسیون هوشمند مدیریت ایمنی کار با ماشین آلات صنعتی'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4336672285142120390</id><published>2010-10-30T15:05:00.000+03:30</published><updated>2010-10-30T15:07:25.667+03:30</updated><title type='text'>حذف روز ايمني در برابر زلزله از تقويم ضرورتي نداشت</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;رئيس پژوهشگاه بين‌المللي زلزله‌شناسي:&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;span style="font-size:130%;color:#ffff00;"&gt;&lt;strong&gt;حذف روز ايمني در برابر زلزله از تقويم ضرورتي نداشت.&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;خبرگزاري فارس: رئيس پژوهشگاه بين‌المللي زلزله‌شناسي گفت: حذف روز ايمني در برابر زلزله از تقويم ملي ايران ضرورتي نداشت و مي توانست به آگاه‌تر كردن مردم كمك كند.&lt;br /&gt;به گزارش خبرنگار علمي خبرگزاري فارس، عباسعلي تسنيمي رئيس پژوهشگاه بين‌المللي زلزله شناسي در جمع خبرنگاران گفت: ما هر ساله در روز 8 آذر مانور زلزله را در مدارس كشور برگزار مي‌كنيم و پژوهشگاه زلزله پيشنهاد داده بود تا اين روز به نام روز ايمني در برابر زلزله نامگذاري شود و اين پيشنهاد به هيئت دولت رفت. &lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;وي افزود: در همين زمان بود كه روز 5 دي زلزله بم با وسعت زيادي اتفاق افتاد و علاوه بر اينكه اين زلزله بسيار مهيب بود از لحاظ زلزله شناسي، زلزله ويژه‌اي بود كه در سه جهت اتفاق افتاد. &lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;تسنيمي ادامه داد: اين زلزله كشور را تحت تأثير قرار داد و باعث شد كه روز 5 دي ماه به نام ايمني در برابر زلزله وارد تقويم شود ولي متأسفانه امسال بدون هيچ دليل موجهي اين روز از تقويم حذف شد. وي گفت:‌ حذف اين روز خللي در برنامه‌هاي ويژه ايمني در برابر زلزله ايجاد نمي‌كند و اين روز از حافظه تاريخي مردم نيز پاك نمي‌شود. &lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;رئيس پژوهشگاه بين‌المللي زلزله افزود: همه فعالان اساتيد و محققان در حوزه زمين شناسي و زلزله تمام فعاليت‌هاي يك ساله خود را در روز 5 دي كه روز مهمي است هرساله ارائه مي‌ردند و مورد بازبيني قرار مي‌دهند. طبيعتا آثار اين فعاليت براي آگاهي دادن عمومي مي‌تواند بسيار مؤثر باشد. وي گفت: زلزله پديده‌اي ناشناخته است و ما بايد فعاليت‌هاي علمي خود را در اين زمينه گسترش دهيم و حذف روز ايمني در برابر زلزله از تقويم ملي ايران زيبا نبود و ضرورتي هم نداشت، مي‌توانست اين روز در تقويم باقي بماند. &lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;وي ادامه داد: اگر ما درست عمل كنيم، وجود اين روز در تقويم مردم را نگران نمي‌كند بلكه باعث آگاه‌تر كردن مردم مي‌شود. ما دوست نداشتيم كه اين روز از تقويم حذف شود و هنوز هم براي برگرداندن آن دير نشده است. &lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4336672285142120390?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4336672285142120390/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4336672285142120390&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4336672285142120390'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4336672285142120390'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_30.html' title='حذف روز ايمني در برابر زلزله از تقويم ضرورتي نداشت'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2737229678883180982</id><published>2010-10-28T08:40:00.004+03:30</published><updated>2010-10-28T08:46:24.412+03:30</updated><title type='text'>خطرهای الکتریسیته ساکن و نکات ایمنی مربوط به آن</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;تهیه توسط دوست خوبم آقاي مهندس محسن عسگري&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;جرقه ناشی از الکتریسیته ساکن به آسانی می تواند در پالایشگاه ها و واحدهای نفت و گاز, انفجار و آتش سوزی ایجاد کند. تقریباً کلیه فرآورده های نفتی مانند بنزین, نفت سفید, سوخت جت, نفت کوره و فرآورده های مشابه در مراحل مختلف پالایش و هنگام جریان یافتن در تلمبه ها, لوله و مخازن, با الکتریسیته ساکن بارور می شوند. مقدار بار الکتریکی آن ها بر حسب نوع محصول, متفاوت است.&lt;br /&gt;به طور کلی در فرآورده هایی که خاصیت هادی بودن بیش تری دارند, مقدار بیش تری الکتریسیته مقاومت بیشتری نشان دهد (فرآورده های تصفیه شده و خالص) معمولاً شدت تولید بار الکتریسیته, به مراتب کم تر است ولی, از آن جا که بار الکتریسیته آن ها به علت مقاوم بودن مایع, به کندی تخلیه می شود, اختلاف پتانسیل بیشتری در آن ها به وجود می آید.&lt;br /&gt;هنگامی که فرآورده های نفتی به مخازن تلمبه می شوند, دو نوع خطر الکتریسیته ساکن به وجود می آید: یکی جرقه هایی که ممکن است در سطح مایع در مخزن تولید شوند و بسیار خطرناک هستند و دیگر آن که در صورت عایق بودن زمین, بار الکتریسیته در مخزن متراکم شود. در حالت دوم, خطر تراکم بار الکتریکی در جداره مخزن با نصب سیم تلفن از بین می رود.&lt;br /&gt;مرتبط بودن مخزن با زمین, به هیچ وجه نمی تواند از خطر اول؛ یعنی, جهش جرقه در سطح مایع, جلوگیری کند بنابراین, تنها راه جلوگیری از انفجار در مخازن, استفاده از سقف شناور و قطع ارتباط هوا با سطح مایعات است. در ضمن مزیت دیگر این گونه مخازن, این است که تشکیل بخارات نفتی به علت تبخیر تا حدود زیادی کاهش می یابد.&lt;br /&gt;برای این که احتمال تولید جرقه در سطح مایع به حداقل برسد, باید از پر کردن مخازن با سرعت زیاد و ریختن مایع از بالا که ایجاد تلاطم در سطح مایع می کند, خودداری شود. بار الکتریسیته ای که به هنگام پر شدن مخزن تولید می شود, پس از ساکن شدن مایع مخزن در مدت چند ثانیه تا حدود دو ساعت تخلیه می شود و پس از آن, خطر تولید جرقه از بین می رود.&lt;br /&gt;برخی نکات ایمنی در مورد الکتریسیته ساکن وجود دارد که توجه به آنها می تواند از وقوع رخدادهای خسارت بار جلوگیری کند از جمله:&lt;br /&gt;هنگام اندازه گیری مایعات در مخازن به وسیله نوار عمق یاب, مسئول اندازه گیری باید پیش از هر چیز, با تماس دست به نرده مخزن, بار الکتریکی را که احتمالاً با خود حمل می کند, به زمین تخلیه و سپس دریچه مخزن را باز کند. همچنین در مدتی که نوار عمق یاب, از درون لوله عمق یابی به پایین فرستاده می شود, باید نوار با جداره لوله در تماس باشد تا از ایجاد جرقه هنگام برخورد وزنه عمق یاب به سطح مایع, جلوگیری شود.&lt;br /&gt;کارکنان باید از پوشیدن کفش های لاستیکی یا تخت لاستیکی که عایق الکتریسیته است, خودداری کنند زیرا, در این حالت بدن آن ها همیشه حامل بار الکتریسیته است و در لحظه برخورد دست یا بدن به یک جسم هادی, ایجاد جرقه می کند که ممکن است در محوطه های خطرناک, موجب انفجار و آتش سوزی شود. این خطر, به ویژه در هوای خشک یا هنگام رعد و برق, شدت می یابد.&lt;br /&gt;هنگامی که لوله های لاستیکی برای بخار زدن یا شست و شوی مخازن برج ها و ظروف پالایش مورد استفاده قرار می گیرند, باید انتهای لوله در محل ورود آب یا بخار به مخزن, با بدنه مخزن به طور کامل مرتبط باشد تا از ایجاد اختلاف پتانسیل با مخزن جلوگیری شود.&lt;br /&gt;هنگام پر کردن بشکه یا ظروف فلزی از مایعات نفتی, باید دقت شود که سر لوله حتماً با بدنه در تماس باشد. از ایستادن در نزدیکی نقاطی که بخار, از لوله یا ظرف, متصاعد می شود و در فضا ابر تشکیل می دهد, خودداری شود زیرا, ممکن است بار الکتریسیته در بدن, القا شده و به محض تماس دست یا بدن با هر شیئی که با زمین ارتباط دارد, جرقه ایجاد شود. به طور کلی, بخار مزبور یا بخاری که ذرات زنگ فلز با خود حمل می کند, هنگام پخش در فضا, الکتریسیته ساکن تولید می کند و چنانچه فردی در نزدیکی این محل, قرار گیرد و کفش تخت لاستیکی پوشیده یا روی تخته ای ایستاده باشد, مقداری بار الکتریسیته با خود حمل می کند و خطر جرقه انفجار به وجود می آورد. لذا, باید توجه داشت که افراد یا اشیایی که نسبت به زمین, عایق هستند در مجاورت جت های بخار قرار نگیرند.&lt;br /&gt;جت یا فواره بخار می تواند الکتریسیته ساکن کرده و برقی که به این ترتیب تولید می شود, اگر به یک جسم عایق برخورد کند, در آن ذخیره شده و در تماس با یک جسم هادی, به صورت جرقه تخلیه می شود که می تواند به اشتعال مواد نفتی منجر شود.&lt;br /&gt;در مواردی که مواد نفتی ذخیره شده در یک مخزن با هوا مخلوط شده است, باید توجه داشت که بخار زدن در مخزن باعث تولید جرقه و انفجار مخلوط نشود. برای جلوگیری از خطر الکتریسیته ساکن, باید لوله بخار زنی همچنین مخزن یا وسیله ای که باید با بخار تمیز و گاز زدا شود, با یک سیم به زمین متصل شود تا برق ایجاد شده در آن ها به زمین تخلیه گردد. بر پایه پژوهش های انجمن نفت ایالات متحده آمریکا, 10 درصد از انفجار ها و حریق هایی که از الکتریسیته ساکن ایجاد شده, مربوط به کاربرد نادرست بخار بوده است لذا, لازم است که کلیه احتیاط های لازم به هنگام بخار زنی یا گاز زدایی از یک دستگاه, به عمل آید.&lt;br /&gt;در مخزن ها, خطرهای الکتریسیته ساکن را که به هنگام نقل و انتقال مواد نفتی و در شرایط ویژه ایجاد می شود, نباید از نظر دور داشت. هنگام نقل و انتقال مواد نفتی دو عامل سبب بارور شدن مخزن با الکتریسیته ساکن می گردد, یکی پخش شدن مایعات به قطرات کوچک, دیگری اصطکاک مایعات هنگام جریان در خطوط لوله. پس از ورود مایع به مخزن و بارور شدن مخزن از دو راه بالا, حتی جرقه کوچکی در آمیزه بخارات نفتی و هوای موجود در بالای مخزن, سبب انفجار و آتش سوزی می شود.&lt;br /&gt;الف) پخش شدن مایعات به قطرات کوچک&lt;br /&gt;این حالت وقتی پدید می آید که مایع از بالای مخزن وارد و به سوی پایین ریزش کند. در هنگام ریزش, بر سطح مایع قطرات ریز پدید می آید. همچنین در مخزن هایی که دارای نازل های هم آمیزی هستند, اگر پیش از بالا آمدن سطح مایع به حد کافی, جریان مایع در نازل برقرار گردد, فوران جت سبب شکسته شدن سطح مایع و تولید قطرات و در نتیجه بارور شدن مخزن با الکتریسیته ساکن می گردد. به این سبب نباید مخزن ها را از بالا پر کرد. به همین منظور نازل های هم آمیزی باید بار کرد که سطح مایع در مخزن کمی بالاتر از نازل باشد.&lt;br /&gt;ب) اصطکاک مایعات هنگام جریان در خطوط لوله&lt;br /&gt;علل ایجاد الکتریسیته ساکن از این راه کمی پیچیده است ولی, به طور کلی می توان گفت که وقتی الکتریسیته ساکن تولید می شود که هیدروکربورها با نا خالصی هایی چون مقدار کمی اسید, آب و مواد معدنی همراه باشند. با زیاد شدن سرعت جریان تنها عامل موثر ایجاد الکتریسیته ساکن نیست, بلکه عوامل شناخته و ناشناخته دیگری نیز هستند که هر یک سهمی در تولید آن دارند.&lt;br /&gt;الکتریسیته ساکن وقتی خنثی می شود که جریان مواد نفتی بدون بار الکتریکی یا دارای دو بار بسیار کم وارد مخزن شود, یا به همان نسبتی که بار الکتریکی تولید می شود, به تدریج از بدنه مخزن به وسیله سیم به زمین تخلیه شود.&lt;br /&gt;حد نصاب قابلیت انفجار بخارات نفتی در مخزن ها, میان 2 تا 15 درصد وزنی غلظت هیدروکربور در آمیزه هوا و بخارات موجود در مخزن است و این شرایط, معمولاً هنگامی که مخزن خالی یا در حال خالی شدن است به وجود می آید. به همین سبب لازم است که این مخزن ها در آغاز با سرعتی کم پر شوند تا از تراکم الکتریسیته ساکن و جرقه زدن جلوگیری گردد.&lt;br /&gt;مخزن های نفت خام و بنزین سبک و نیز مخزن های نفت گاز و فرآورده های سنگین از این نقطه نظر ایمن تر هستند, در گروه نخست درصد غلظت هیدروکربور در آمیزه بخارات, بیش تر از بیش ترین حد غلظت قابل انفجار بوده و در گروه دوم از کمترین حد, کم تر است. بر عکس مخزن های نفتی سنگین و نفت سفید از این نظر خطرناکترند زیرا, هنگامی که مخزن خالی است, درصد هیدروکربور در فضای بخار در حد نصاب قابل انفجار می باشد. بسیار خطرناک خواهد بود. به طور خلاصه می توان گفت که انفجار به دو سبب صورت می گیرد: یکی در صورتی که الکتریسیته ساکن تولید شود و دیگر هنگامی که در مخزن, آمیزه بخارات قابل انفجار موجود باشد.&lt;br /&gt;اگر احتمال داده شود که بخارات قابل انفجار در مخزن موجود است, نکته های زیر باید رعایت گردد:&lt;br /&gt;مخزن ها نباید از بالا پر شوند, از دمیدن هوا در خطوط لوله به سوی مخزن خودداری گردد.&lt;br /&gt;تلمبه کردن مواد نفتی به مخزن در آغاز, با سرعتی کم انجام شود, تا هنگامی که این مخزن ها حال پر شدن هستند, نباید موجودی آن ها به وسیله نوار یا میله های فلزی اندازه گیری شود زیرا, احتمال دارد که شخص حامل نوار عمق سنج, با خود بار الکتریسیته داشته باشد و با تماس نوار به دیواره مخزن, جرقه ساکن تولید گردد.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;سیم اتصال به زمین (Earthing wire)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;دیواره همه مخزن ها, باید به وسیله سیم به زمین متصل شود. ابتدا چاله ای به عمق کافی تا آن جا که به رطوبت طبیعی زمین برسد, حفر می شود. سپس یک سیم مسی یا نقره ای یا آلومینیومی چند لا با مقاومت الکتریکی کم را به یک صفحه مسی یا پرچ یا جوش دادن, اتصال داده و صفحه مذکور را به صورت تیغه ای در چاله قرار می دهند و اطراف آن را توسط خاک, خاک زغال و نمک طعام یا جوش شیرین تا روی صفحه مسی شفته می کنند و بقیه چاله را با خاک پر می کنند. کار این سیم, هدایت بار الکتریسیته ساکن از مخزن به زمین و جلوگیری مصون باشد و سالی یک بار توسط شخص آگاه مورد بررسی و آزمایش قرار گیرد تا در صورتی که مقاومت آن در اثر اکسیداسیون زیاد شده باشد, تعویض یا رفع عیب گردد.&lt;br /&gt;برای حفظ دستگاه ها و وسایل فلزی از خطرات الکتریسیته ساکن, اتصال این وسایل به زمین, بسیار ضروری است. همانطور که بیان شد, یک سر سیم مسی را به دستگاه و سر دیگر آن را, به لوله یا میله ای که در عمق خاک کار گذاشته شده است, وصل می کنند. لوله های آب زیرزمینی نیز, وسیله بسیار موثری برای تخلیه الکتریکی به زمین است. &lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;متصل بودن وسایل فلزی و ادوات الکتریکی به زمین از دو نظر مهم است:&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;الف) پیشگیری از خطر آتش سوزی: هم زمان با القاء بار الکتریسیته ساکن در اشیا فلزی, تخلیه الکتریکی به زمین نیز صورت می گیرد و به این ترتیب, تراکم الکتریسیته ساکن در شیئی فلزی و خطر تولید جرقه در اثر تماس با بدن انسان یا اشیا دیگری که با زمین ارتباط دارند, از بین می روند و در نتیجه, خطر آتش سوزی, به کمترین میزان خود می رسد.&lt;br /&gt;ب) ایمنی افراد و وسایل: به منظور حفظ جان افرادی که با وسایل برقی سروکار دارند و همچنین جلوگیری از آسیب دیدن وسایل برقی, لازم است کلیه ادوات و وسایل برقی به وسیله سیم با زمین مرتبط باشند.&lt;br /&gt;جریان الکتریسیته, مانند جریان گازها و مایعات در لوله های تحت فشار سعی می کند در مسیر خود راهی به خارج پیدا کند اما, وجود عایق ها, مانع از انحراف جریان الکترون ها است. حال اگر روکش عایق سیم, معیوب باشد و قسمتی از سیم لخت به شیئی فلزی اتصال پیدا کند, جریان برق با آن شی برقرار می شود و اگر بدن انسان با شی مزبور, تماس پیدا کند, ممکن است موجب وارد آمدن شوک الکتریکی و مرگ شود.&lt;br /&gt;محافظت مخزن ها از آتش و اطفاء حریق آنها&lt;br /&gt;از نظر ایمنی و پیشگیری از خطرات آتش سوزی, مخزن های سقف شناور بر مخزن های سقف ثابت, برتری بسیاری دارند زیرا, احتمال روی دادن آتش سوزی در این مخزن ها, کمتر و در صورت پیش آمدن این خطر, مهار کردن و مبارزه با آتش, به مراتب آسانتر است.&lt;br /&gt;از آنجا که سرعت کار در مبارزه با آتش سوزی یک مخزن بزرگ نفتی اهمیتی بسیار دارد و اگر در دقایق نخستین, آتش سوزی مهار نشود, بیم آتش گرفتن مخزن خواهد بود, مخزن های نفتی باید با وسایل و تجهیزات ثابت مبارزه با آتش, مجهز شوند تا در موارد آتش سوزی بتوان در کمترین زمان از گسترش آتش جلوگیری و آن را خاموش کرد. از بهترین موادی که تا کنون برای خاموش کردن آتش در مخزن ها مورد استفاده قرار گرفته اند, یکی کف ضد حریق (Foam) و دیگر پودر خشک (Dry Powder) است. پودر خشک را با مخزن های متحرک آتش نشانی, به محل آتش گرفته آورده, به وسیله لوله های بلند پلاستیکی و با فشار روی مخزن می پاشند, ولی کف ضد حریق را به وسیله وسایل و تجهیزاتی که روز مخزن ها نصب شده, به درون مخزن تزریق می کنند.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;کار تزریق کف به مخزن از دو راه انجام می گیرد:&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;1- تزریق کف از بالای مخزن (Foam chamber): کف ضد آتش سوزی به وسیله تلمبه از مخزن متحرک به سیستم کف رسانی که به طور ثابت روی هر مخزن از نوع سقف ثابت نصب شده, منتقل گردیده, در بالای مخزن وارد جعبه پخش کف (Foam Drum) می گردد. این جعبه, روی سقف مخزن نصب شده و کف ضد آتش از این جعبه و از راه لوله مشبکی که روی محیط مخزن قرار گرفته بر سطح مایع در مخزن پاشیده شده, با پوشاندن سطح مایع و قطع رابطه هوا با نفت, سبب خاموش شدن آتش می گردد.&lt;br /&gt;2- تزریق کف از زیر مخزن (subsurface injection): برای پوشاندن سطح مواد نفتی در مخزن ها با کف, ممکن است کف را از زیر وارد مخزن کرد از آنجا که وزن مخصوص کف از مواد نفتی سبک تر است, کف تا سطح مایع بالا رفته, آن را می پوشاند و در ضمن با ایجاد تلاطم در سطح نفت و در نتیجه سرد کردن حرارت مایع نفتی که به طور مستقیم در تماس با آتش بوده است, عمل تبخیر مواد نفتی را کندتر کرده از این راه فرو نشاندن آتش را آسان تر می کند. از آنجا که هزینه های سرمایه ای نصب این وسایل از هزینه های سیستم تزریق از بالای مخزن, کم تر بوده و از نظر نتیجه کار نیز موثرتر است, این سیستم در پالایشگاه های جدید و نوبنیاد بیش تر متداول شده است. شرکت ملی نفت ایران نیز این روش را برای پالایشگاه های جدید و نوبنیاد بیش تر متداول شده است. شرکت ملی نفت ایران نیز این روش را برای پالایشگاه های جدید خود برگزیده است.&lt;br /&gt;به طور کلی, در مورد اطفاء حریق نفت خام (Crude oil), نکاتی وجود دارد که در مورد سایر مخازن وجود ندارد. خاموش کردن نفت خام مانند کلیه مایعات دیگر, در اثر بر هم زدن توازن میزان هوا و گاز صورت می گیرد. در هنگام خاموش کردن و اطفاء حریق نفت خام, باید به انتقال حرارت در قسمت های پایین تر از سطح آتش و شعله توجه نمود. در اکثر آتش سوزی های مخازن با مخزنی بدون سقف روبرو خواهیم شد که یا سقف شناور آن, غرق شده یا سقف ثابت آن در اثر انفجار و شعله, از بین رفته است. بخارات مخلوط خام با میزان هوای کافی و غیر کافی, ترکیب شده و به آسانی احتراق ناقص یا کاملی به وجود می آورد. به علت پایین تر بودن دمای جوش ترکیبات سبک موجود در نفت خام, این ترکیبات سریع تر به بخار تبدیل شده و در حجم وسیع و زمان کم, باعث شعله ور شدن مخزن می شوند. در همین زمان, ترکیبات سنگین تر در مجاورت سطح شعله گرم شده ولی اکثراً به دلیل نرسیدن به دمای جوش و خروج مواد سبک موجود در لایه های پایین تر, به جای آن ها به لایه های پایین تر سقوط کرده و فقط میزان کمی از آن ها در مراحل اولیه احتراق شرکت می کنند و بعضاً به صورت ملکولی در جریان حرکتی ناشی از احتراق از سطح شعله و بستر آتش, جدا شده و ستون دود را ایجاد می کنند. سقوط مواد سنگین با دمایی بالا به لایه های زیرین شعله باعث انتقال حرارت به شیوه جابجایی می شوند و تبادل حرارت آن ها با مایعات (نفت خام), باعث گرم شدن آن ها و بالا رفتن مولکولهای سبک تر و رسیدن آن ها به بستر آتش و شعله می شود. مواد سبک در نزدیکی سطح شعله و بستر آتش به دمای مطلوب جهت تبخیر رسیده و بخارات آن ها در سطح بستر آتش, با هوا ترکیب شده و باعث ادامه حریق می شوند. هر چه حرارت زیاد و سوخت ادامه داشته باشد, این حرکت ادامه داشته و به قسمت های پایین تر و کف مخزن انتقال می یابد و با کم شدن میزان آنها به آرامی فاصله شعله تا سطح مایع کمتر می شود. قبل از آن دمای سطح مایع نزدیک به 300 درجه فارنهایت می رسد. با رسیدن به حرارت با لایه های پایین و کف مخزن در صورت موجود بودن آب در آن ناحیه, تبخیر شده و افزایش حجم بسیار بالای آن (در حدود 1600 تا 1700 برابر), باعث بالا رفتن سطح مایع و لبریز و پاشیده شدن آن به محیط اطراف می گردد (Boil over). لذا, باید از هرگونه ورود آب به درون آن ها در هنگام اطفاء حریق مخازن, خودداری نمود و صرفاً باید جهت خنک نمودن جداره مخزن استفاده نمود. در اکثر مخازن, سیستم خنک کننده اسپری آب برای جداره مخزن از سیستم خنک کننده سقف مخزن جداگانه طرحی و از مسیرهای جداگانه و والوهای مجزا استفاده می شود و در صورت انهدام سقف, به سرعت باید جریان آب منتهی به سقف را قطع نمود تا از هرگونه ورود آب به مخزن جلوگیری گردد.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;اطفاء آتش مخازن پروپان&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;در زمان اطفاء آتش مخازن پروپان, همواره احتمال انفجاری با نام انفجار ابر بخارات مایع در حال جوشش BLEVE (Boiling Liquid Expanding Vapor Explosion) وجود دارد. جهت کاهش این ریسک, آتش نشان ها باید به توصیه های زیر توجه کنند:&lt;br /&gt;1- اطفاء آتش باید از حداکثر فاصله ممکن صورت پذیرد و تا حد امکان از نازل ها و مانیتور های ثابت که نیاز به نفر ندارند, استفاده شود.&lt;br /&gt;2- مخزن را با مقادیر بسیار زیاد آب تا زمان اطفاء کامل مخزن خنک نمایید.&lt;br /&gt;3- آب را به طور مستقیم به محل نشت گاز یا ادوات ایمنی نصب شده روی مخزن نگیرید زیرا, ممکن است باعث یخ زدگی شود.&lt;br /&gt;4- در صورت افزایش صدای نشت از ادوات ایمنی نصب شده بر مخزن یا مشاهده تغییر رنگ مخزن, به سرعت محل را ترک نمایید.&lt;br /&gt;5- در آتش های بزرگ از این نوع سعی در استفاده از ادوات ثابت شود و بهتر است بعد از نصب این ادوات, مخزن را تا زمان سوختن کامل محتویات آن به حال خود رها کنید.&lt;br /&gt;6- آگاه باشید که در هنگام وقوع پدیده انفجار ابر بخارات تکه های مخزن ممکن است به هر سمتی پرتاب شود لذا, نباید محوطه خارج از دایک مخزن محل امن در نظر گرفته شود.&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2737229678883180982?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2737229678883180982/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2737229678883180982&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2737229678883180982'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2737229678883180982'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_28.html' title='خطرهای الکتریسیته ساکن و نکات ایمنی مربوط به آن'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-4399723111825974067</id><published>2010-10-28T07:24:00.004+03:30</published><updated>2010-10-28T07:49:21.215+03:30</updated><title type='text'>Arc Fault Circuit Interrupter)  AFCI)</title><content type='html'>&lt;div dir="ltr" align="left"&gt;&lt;a href="http://www.geindustrial.com/images/products/AFCI_prod_pg_img.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 144px; CURSOR: hand; HEIGHT: 182px; TEXT-ALIGN: center" alt="" src="http://www.geindustrial.com/images/products/AFCI_prod_pg_img.jpg" border="0" /&gt;&lt;/a&gt;Residential electrical fires occur around 70,000 times a year. A significant portion of these fires can be attributed to arc faults. An arc fault is the flow of electricity over an unintended path. These arcs can exceed temperatures of 10,000° F and easily ignite combustible materials in the home. AFCIs are devices that protect your home by detecting dangerous arcs and safely de-energizing the circuit. Arc faults arise from a number of situations, including: • Damaged wires&lt;br /&gt;• Receptacle leakage&lt;br /&gt;• Neutral leads pinched to grounded metal box&lt;br /&gt;• Worn electrical insulation&lt;br /&gt;• Loose electrical connections&lt;br /&gt;• Shorted wires&lt;br /&gt;• Wires or cords in contact with vibrating metal&lt;br /&gt;• Overheated or stressed electrical cords and wires&lt;br /&gt;• Misapplied/damaged appliances&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;Branch/Feeder AFCI&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;A Branch/Feeder AFCI has the ability to detect and neutralize a parallel arc fault, which is the unintentional flow of electricity between two separate wires. There are three types of parallel arc faults: line-to-line, line-to-ground, and line-to-neutral. The Branch/Feeder AFCI is permitted by the 1999-2005 NEC® Code.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;&lt;span style="color:#ff0000;"&gt;Combination AFCI&lt;/span&gt; &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;GE's Combination AFCI delivers 5 kinds of protection:&lt;br /&gt;&lt;span style="color:#33ff33;"&gt;1-Parallel protection – Just like its Branch/Feeder counterpart, Combination AFCI can detect and neutralize parallel arc faults&lt;br /&gt;2-Series Protection – A series arc fault is the unintended flow of electricity over a gap within a single wire. These arc faults were not detectable until advanced technology allowed the development of the Combination AFCI breaker.&lt;br /&gt;3-Ground protection – Arcing between a single conductor and a ground line&lt;br /&gt;4-Overload protection&lt;br /&gt;5-Short circuit protection&lt;br /&gt;&lt;/span&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 276px; CURSOR: hand; HEIGHT: 235px; TEXT-ALIGN: center" alt="" src="http://www.arcadvisor.com/images/diagramA.gif" border="0" /&gt;The Combination AFCI represents advancement in technology and home protection. The 2008 NEC® Code mandates that all dwelling areas in the home have Combination AFCI protection:&lt;br /&gt;• Bedroom&lt;br /&gt;• Living room&lt;br /&gt;• Dining room&lt;br /&gt;• Sun room&lt;br /&gt;• Hallway&lt;br /&gt;• Closet&lt;br /&gt;• Finished basement&lt;br /&gt;• Rec room &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-4399723111825974067?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/4399723111825974067/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=4399723111825974067&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4399723111825974067'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/4399723111825974067'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/arc-fault-circuit-interrupter-afci.html' title='Arc Fault Circuit Interrupter)  AFCI)'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3893214096171859133</id><published>2010-10-27T13:33:00.000+03:30</published><updated>2010-10-27T13:34:55.119+03:30</updated><title type='text'>سرعت غيرمجاز؛ مهم ترين علت تصادفات جاده اي</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;معاون عمليات پليس راه كشور با بيان اين كه تخطي از سرعت مطمئنه مهم ترين دليل تصادفات 24 ساعت گذشته بوده است، گفت: تخطي از سرعت مطمئنه، عدم توجه به جلو، انحراف به چپ و عدم رعايت حق تقدم مهم ترين علل تصادفات جاده اي است.سرهنگ پرويز سياح البرزي در گفتگو با ايسنا، ضمن هشدار نسبت به عدم استفاده از تلفن همراه در حين رانندگي افزود: تلفن همراه يكي از ابزارهاي انحراف ذهني و كاهش تمركز رانندگان است كه سبب عدم توجه به جلو شده و در نتيجه رانندگان را در وضعيت پرخطر قرار مي دهد و متوجه نقاط حساس و حادثه خيز نمي شوند.&lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;روزنامه جام جم&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3893214096171859133?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3893214096171859133/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3893214096171859133&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3893214096171859133'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3893214096171859133'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_27.html' title='سرعت غيرمجاز؛ مهم ترين علت تصادفات جاده اي'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-351469329596602210</id><published>2010-10-26T13:00:00.002+03:30</published><updated>2010-10-26T13:18:16.541+03:30</updated><title type='text'>كتاب آموزشي «كابل خودنگهداروهادي روكش دار » منتشر شد</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=167&amp;amp;viewkey="&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 354px; CURSOR: hand; HEIGHT: 256px; TEXT-ALIGN: center" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=167&amp;amp;viewkey=" border="0" /&gt;&lt;/a&gt; &lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;باتلاش وانجام يك كارتيمي فشرده درشركت توزيع نيروي برق مشهد:&lt;br /&gt;كتاب آموزشي «كابل خودنگهداروهادي روكش دار » منتشر شد&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;در راستاي گسترش فرهنگ وترويج استفاده ازكابل خودنگهداروجايگزيني آن باسيم هاي مسي در شبكه هاي فشارضعيف و فشار متوسط ، نخستين كتاب مصّور وآموزشي كشورتحت عنوان « كابل خودنگهداروهادي روكش دار،راهي ميان بُر،براي نوسازي وپايداري شبكه هاي توزيع » باهمّت جمعي ازكاركنان شركت توزيع نيروي برق مشهد تهيه وانتشاريافت.&lt;br /&gt;به گزارش خبرنگاروصل ( نشريه شركت توزيع نيروي برق مشهد )،اين اثر كه به صورت چهاررنگ ودر قطع وزيري با تيراژ 2000 نسخه به چاپ رسيده، شامل بخش هاي گوناگوني از جمله : مشخصات فني وساختاركابل خودنگهدار، معرفي تجهيزات ويراق آلات، ابزار وروش هاي اجرايي احداث وبهره برداري ازاين نوع شبكه هاو روش محاسبات مكانيكي مي باشد.&lt;br /&gt;گفتني است ويژگي بارز اين كتاب تلفيق اطلاعات فنّي برق با ادبيات روان فارسي بوده و درمجموع به گونه اي ويراستاري شده كه براي كلاس هاي آموزشي سطوح تكنيسيني وكارگري نيز قابل مطالعه و يادگيري باشد.دربخشي ازپيش گفتاراين كتاب به قلم مهندس علي سعيدي(مديرعامل شركت توزيع نيروي برق مشهد)آمده است:&lt;br /&gt;« استفاده صحيح از كابل هاي خودنگهدار فشار ضعيف و فشارمتوسط و به كارگيري هادي هاي روكش دار در سطح فشار متوسط ، به طور جّدي مي تواند به عنوان يكي ازراه حلّ هاي ساده وارزان ،شركت هاي توزيع برق كشور را براي غلبه بر مشكلات مبتلابه آنان ياري رسانيده وبه ويژه در بخش فشار ضعيف، راهكار بسيارخوبي براي حلّ مشكلات شبكه‌هاي توزيع باشد» به شرطي كه :&lt;br /&gt;- اولاً : آموزش لازم به مشاوران طراح وناظر،پيمانكاران و مجريان داده شود.&lt;br /&gt;- ثانياً: پيمانكاران داراي صلاحيت دراين موضوع تعيين گرديده و به آنها تائيديه ي كار داده شود(به اين معني كه هرپيمانكارمعمولي احداث شبكه،بدون داشتن تائيديه ي مذكور،نتواندشبكه ي كابل خودنگهداراجرانمايد)&lt;br /&gt;- ثالثاً: از يراق آلات و اتصالات استاندارد استفاده گردد.&lt;br /&gt;- رابعاً: بااعمال نظارت هاي دوره اي،ازمناسب بودن اتصّال كانكتورهاوحسن انجام كارمجريان وپيمانكاران اطمينان حاصل شود.&lt;br /&gt;در اين کتاب سعی شده به زبانی ساده، ضمن معرفی مزايا و معايب هادی های مسی و آلومينيومی،دلايل ضرورت گرايش به سمت کابل های خودنگهدار وهادی های روکش دار با ذکر مثال های عملی بيان شود .&lt;br /&gt;ازاين رو، جلد اول بیشتر به صورت کاربردی به« کابل خودنگهدار فشار ضعيف و فشار متوسط»پرداخته و پس از معرفی آنها، بر آشنايی با« کابل خودنگهدار مهار دار»به لحاظ سازگاری بيشتر با شرايط کشورمان، تکيه دارد . سپس خواننده با یراق آلات ، ابزار کارو در نهايت روش های اجرايی استاندارد احداث شبکه های کابل خودنگهدار آشنا مي گردد.&lt;br /&gt;شايان ذكر اينكه همچنين برای جلوگيری ازپراکنده نويسی و ايجاد آشفتگي احتمالي درذهن خواننده , برخي اطلاعات اضافی که ممکن است مفید واقع شود، ازمتن اصلي كتاب خارج ودر قالب ضمائم ارائه شده است .&lt;br /&gt;هياًت تحريريه نشريه وصل، به نمايندگي ازمديريت عامل وشوراي معاونين شركت توزيع نيروي برق مشهد،بدين وسيله ازتلاش،جديّت صميمانه ي آقايان:رضاوهاب رجائي،محسن ابوترابي ومحمدعلي نورائي درامرتاليف كتاب وآقايان : حميداسماعيلي(مديراموربرق ناحيه 2مشهد)حسين آردم(معاون مديراموردربهره برداري)حسن آرش(رئيس اداره برنامه ريزي ومهندسي)به لحاظ همكاري وپشتيباني لازم وهمچنين اعضاي گروه اجرايي احداث شبكه ي كابل خودنگهدارآقايان:جوادممدوحي،علي تيموري،محمدرضاخالقي ومحسن شوكتي درامرتهيه ي عكس هاي مراحل اجرايي كارقدرداني مي نمايد.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-351469329596602210?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/351469329596602210/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=351469329596602210&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/351469329596602210'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/351469329596602210'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_2684.html' title='كتاب آموزشي «كابل خودنگهداروهادي روكش دار » منتشر شد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2861295785187191390</id><published>2010-10-26T12:47:00.001+03:30</published><updated>2010-10-26T12:59:41.827+03:30</updated><title type='text'>کلید پریز هوشمند برق ساخته شد</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=164&amp;amp;viewkey="&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 265px; CURSOR: hand; HEIGHT: 180px; TEXT-ALIGN: center" alt="" src="http://ohsms.meedc.ir/index.php?module=photo_gallery&amp;amp;func=viewimage&amp;amp;iid=164&amp;amp;viewkey=" border="0" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;color:#66ff99;"&gt;یک مبتکر ایرانی موفق به ساخت وسیله ای شده است که در زمان کار با پریز برق، مانع از برق گرفتگی می شود.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;به گزارش باشگاه خبرنگاران، شهرام مجردی گفت:این سیستم تفکیک مصرف برنامه ریزی شده است که در صورت اعمال فرکانس و شناسایی افراد در زمان کاربر پریز برق مانع از برق گرفتگی می شود.وی ادامه داد:همچنین این وسیله درصورت نبود افراد با ارسال فرکانس،برق دستگاه های در حال کار را قطع و درصورت آمدن فرد، مجدد برق را وصل می کند.مجردی افزود: وسیله یاد شده در مدت یک ماه و با هزینه ای نامشخص طراحی و با شماره 5140 در اداره انجمن مخترعان ثبت شده است.&lt;br /&gt;باشگاه خبرنگاران&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2861295785187191390?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2861295785187191390/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2861295785187191390&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2861295785187191390'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2861295785187191390'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_8125.html' title='کلید پریز هوشمند برق ساخته شد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7721030315795191118</id><published>2010-10-26T12:46:00.000+03:30</published><updated>2010-10-26T12:47:38.824+03:30</updated><title type='text'>در پارک علم و فناوری دانشگاه سمنان دستگاه آموزشی مانور پست فشار قوی ساخته شد</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;strong&gt;&lt;span style="color:#ffff33;"&gt;دستگاه آموزشی مانور پست فشار قوی در پارک علم و فناوری دانشگاه سمنان طراحی و ساخته شد.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;به نقل از ایسنا، دکتر رضا کی پور، مدیر مرکز رشد واحدهای فناور پارک علم و فناوری دانشگاه سمنان با اعلام این مطلب گفت: این دستگاه توسط شرکت فنی و مهندسی "ابتکار الکتریک قومس" که یکی از شرکتهای فناور مستقر در این مرکز است، طراحی و ساخت شده است.&lt;br /&gt;وی در خصوص کاربرد این دستگاه آموزشی اضافه کرد: این دستگاه می‌تواند تابلوی فرمان مستقر در اتاق کنترل پست‌های فشار قوی را شبیه سازی کرده و به اپراتورهای پست‌های فشار قوی این امکان را بدهد تا مانورهای مختلفی مانند خروج خطوط، ترانس‌ها و ... را بدون قطع شدن واقعی تجهیزات پست و بدون اعمال خاموشی، انجام دهند.&lt;br /&gt;کی پور در خصوص مزایای استفاده از این گونه تجهیزات آموزش مجازی افزود: صرفه‌جویی در هزینه و زمان، کاهش مخاطرات احتمالی و جلوگیری از آسیب‌های وارده به دستگاه‌ها و تجهیزات از مزایای کار با این شبیه ساز آموزشی است.&lt;br /&gt;وی تاکید کرد: این دستگاه شبیه ساز آموزشی در مراکزی همچون شرکت‌های برق منطقه‌ای‌، دانشکده‌های مربوطه و گروه‌های آموزشی برق - قدرت دانشگاه‌ها و مراکز آموزش عالی کشور و همچنین شرکتهای بهره برداری اپراتوری و شرکتهای سازنده پست‌های برق کاربرد دارد.&lt;br /&gt;گفتنی است در حال حاضر بالغ بر 25 شرکت و واحد صنعتی در مرکز رشد واحدهای فناور پارک علم وفناوری دانشگاه سمنان مستقر بوده و با استفاده از پتانسیل‌های این مرکز به فعالیت‌های علمی - پژوهشی اشتغال دارند.&lt;br /&gt;ایسنا&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7721030315795191118?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7721030315795191118/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7721030315795191118&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7721030315795191118'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7721030315795191118'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_26.html' title='در پارک علم و فناوری دانشگاه سمنان دستگاه آموزشی مانور پست فشار قوی ساخته شد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6139224883558873756</id><published>2010-10-25T17:07:00.004+03:30</published><updated>2010-10-25T17:24:40.283+03:30</updated><title type='text'>برقگرفتگي يك تكنسين شركت شبكه هاي محلي ارتباطات اينترنت، در پاتايا</title><content type='html'>&lt;a href="http://www.pattayadailynews.com/en/wp-content/uploads/2010/09/2541.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 372px; CURSOR: hand; HEIGHT: 228px; TEXT-ALIGN: center" alt="" src="http://www.pattayadailynews.com/en/wp-content/uploads/2010/09/2541.jpg" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;September 16, 2010&lt;br /&gt;يك تكنسين شركت شبكه هاي محلي ارتباطات اينترنت the Three Broadband Internet provider) 3BB) در پاتايا Pataya كه در حال نصب تابلو نئون بر روي پايه برق بود ، در اثر نزديك شدن به شبكه برق ولتاژ قوي دچار برق گرفتگي شد.&lt;br /&gt;آقاي سوك بوم رونگ Sookbumrung پس از برقگرفتگي بر روي زمين سقوط نموده كه بلافاصله پس از حضور نيروهاي امدادي وي را به بيمارستان منتقل مي نمايند. تا زمان مخابره اين خبر مصدوم در بيمارستان در قيد حيات بوده و به دليل سوختگي هاي شديد تحت درمان مي باشد.&lt;br /&gt;منبع خبر:&lt;br /&gt;&lt;div align="left"&gt;&lt;a href="http://www.pattayadailynews.com/en/2010/09/16/3bb-technician-suffers-near-fatal-electrocution-in-pattaya/"&gt;http://www.pattayadailynews.com/en/2010/09/16/3bb-technician-suffers-near-fatal-electrocution-in-pattaya/&lt;/a&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6139224883558873756?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6139224883558873756/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6139224883558873756&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6139224883558873756'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6139224883558873756'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_5199.html' title='برقگرفتگي يك تكنسين شركت شبكه هاي محلي ارتباطات اينترنت، در پاتايا'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7032040909244842237</id><published>2010-10-25T07:10:00.001+03:30</published><updated>2010-10-25T07:10:57.593+03:30</updated><title type='text'>تغییر نگرش(دیدگاه)</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;ميگويند در كشور ژاپن مرد ميليونري زندگي ميكرد كه از درد چشم خواب بچشم نداشت و براي مداواي چشم دردش انواع قرصها و آمپولها را استفاده كرده اما نتيجه چنداني نگرفته بود. وي پس از مشاوره فراوان با پزشكان و متخصصان زياد درمان درد خود را مراجعه به يك راهب مقدس و شناخته شده مي بيند. وي به راهب مراجعه مي كند و راهب نيز پس از معاينه وي به او پيشنهاد می دهد كه مدتي به هيچ رنگي بجز رنگ آبی نگاه نكند.&lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;وي پس از بازگشت از نزد راهب به تمام مستخدمين خود دستور ميدهد با خريد بشكه هاي رنگ آبی تمام خانه را با آبی رنگ آميزي كنند . همينطور تمام اسباب و اثاثيه خانه را با همين رنگ عوض ميكند. پس از مدتي رنگ ماشين ، ست لباس اعضاي خانواده و مستخدمين و هر آنچه به چشم مي آيد را به رنگ آبی و تركيبات آن تغيير ميدهد و البته چشم دردش هم تسكين مي يابد. بعد از مدتي مرد ميليونر براي تشكر از راهب وي را به منزلش دعوت مي نمايد. راهب نيز كه با لباس نارنجي رنگ به منزل او وارد ميشود متوجه ميشود كه بايد لباسش را عوض كرده و خرقه اي به رنگ آبی به تن كند. او نيز چنين كرده و وقتي به محضر بيمارش ميرسد از او مي پرسد آيا چشم دردش تسكين يافته ؟ مرد ثروتمند نيز تشكر كرده و ميگويد :\" بله . اما اين گرانترين مداوايي بود كه تاكنون داشته .\" مرد راهب با تعجب به بيمارش ميگويد بالعكس اين ارزانترين نسخه اي بوده كه تاكنون تجويز كرده ام. براي مداواي چشم دردتان، تنها كافي بود عينكي با شيشه آبی خريداري كنيد و هيچ نيازي به اين همه مخارج نبود.براي رسیدن به اهدافت نميتواني تمام دنيا را تغيير دهي ، بلكه با تغيير دیدگاهت ميتواني دنيا را به كام خود درآوري. تغيير دنيا كار بسیار دشواری است اما تغيير نگرش ارزانترين و موثرترين روش مي باشد.&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7032040909244842237?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7032040909244842237/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7032040909244842237&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7032040909244842237'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7032040909244842237'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_25.html' title='تغییر نگرش(دیدگاه)'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2343640946808118719</id><published>2010-10-24T10:32:00.004+03:30</published><updated>2010-10-28T07:44:54.810+03:30</updated><title type='text'>Arc Fault Circuit Interrupter (AFCI) Protection</title><content type='html'>&lt;div dir="ltr" align="left"&gt;&lt;a href="http://enews.penton.com/enews/electricalzone/codewatch/2008_08_07_august_7_2008_codewatch/a080806/graphic"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 312px; CURSOR: hand; HEIGHT: 234px; TEXT-ALIGN: center" alt="" src="http://enews.penton.com/enews/electricalzone/codewatch/2008_08_07_august_7_2008_codewatch/a080806/graphic" border="0" /&gt;&lt;/a&gt;By Mike Holt&lt;br /&gt;Arc fault circuit interrupter protection requirements for 15A and 20A, 120V dwelling unit circuits were expanded again. Section 210.12(B) now reads as follows:&lt;br /&gt;"All 15A or 20A, 120V branch circuits that supply outlets in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar areas shall be protected by a listed AFCI device of the combination type."&lt;br /&gt;The 120V circuit limitation means AFCI protection isn't required for equipment rated 230V, such as baseboard heaters or room air conditioners. In addition, AFCI protection is not required in rooms or areas protected by GFCIs. Though not required by the Code, both AFCI and GFCI protection can be provided for the same branch circuits or receptacle outlets, as the different protection technologies are compatible.&lt;br /&gt;In addition, a new Fine Print Note clarified dwelling unit AFCI protection requirements of fire alarm circuits, and the rules on locating the AFCI device were rewritten to relax the restrictions.&lt;br /&gt;"FPN No. 3: See 760.41 and 760.121 for power-supply requirements for fire alarm systems."&lt;br /&gt;Smoke alarms connected to a 15A or 20A circuit must be AFCI-protected if the smoke alarm is located in the bedroom of a dwelling unit. The exemption from AFCI protection for the "fire alarm circuit" contained in 760.41 and 760.121 doesn't apply to the single and multiple station smoke alarm circuit typically installed in dwelling unit bedroom areas. This is because a smoke alarm circuit isn't a fire alarm circuit as defined in NFPA 72, National Fire Alarm Code. Unlike single and multiple station smoke alarms, fire alarm systems are managed by a fire alarm control panel.&lt;br /&gt;"Exception No. 1: The AFCI protection device can be located at the first outlet if the circuit conductors are installed in RMC, IMC, EMT or steel Type AC, and the AFCI device is contained in a metal outlet or junction box."&lt;br /&gt;Type MC cable without a bare aluminum grounding/bonding conductor does not fall within the scope of this exception because the armor cable is thinner than that of Type AC cable.&lt;br /&gt;"Exception No. 2: AFCI protection can be omitted for branch-circuit wiring to a fire alarm system in accordance with 760.41(B) and 760.121(B), if the circuit conductors are installed in RMC, IMC, EMT, or steel armored Type AC cable."&lt;br /&gt;This new Fine Print Note alerts Code users to the fact that AFCI protection is not required for the "fire alarm circuit," but caution must be exercised because 760.41 and 760.21 don't apply to the single and multiple station smoke alarm circuit typically installed in dwelling unit bedroom areas. This is because a smoke alarm circuit isn't a fire alarm circuit as defined by NFPA 72, National Fire Alarm Code. Unlike single and multiple station smoke alarms (smoke detectors), fire alarm systems are managed by a fire alarm control panel, which qualifies it as a fire alarm system. &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2343640946808118719?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2343640946808118719/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2343640946808118719&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2343640946808118719'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2343640946808118719'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/arc-fault-circuit-interrupter-afci_24.html' title='Arc Fault Circuit Interrupter (AFCI) Protection'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-1911827836152651085</id><published>2010-10-24T09:09:00.001+03:30</published><updated>2010-10-24T09:11:58.690+03:30</updated><title type='text'>همايش روز ملی کاهش اثرات بلايای طبيعی در برق آذربايجان</title><content type='html'>&lt;span style="font-size:130%;"&gt;همزمان با روز ملی کاهش اثرات بلايای طبيعی همايش کميته های ايمنی صنعت برق آذربايجان از سوی دبيرخانه کميته عالی ايمنی اين شرکت برگزار شد .&lt;/span&gt;&lt;br /&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 124px; CURSOR: hand; HEIGHT: 176px; TEXT-ALIGN: center" alt="" src="http://www.irarec.com/arec/pbp/news/emeni.jpg" border="0" /&gt;در اين همايش که مهندس ساعی مشاور استاندار و مدير کل ستاد بحران آذربايجان شرقی ، مهندس بهاری وند مدير عامل شرکت برق منطقه ای آذربايجان ، مديران عامل شرکت های صنعت برق در استان و اعضای کارگروهها و کميته های ايمنی صنعت برق استان حضور داشتند ، ابتدا مهندس جواد غلامی دبير کميته عالی ايمنی برق آذربايجان گزارشی از عملکرد شرکت در سيستم های مديريت ايمنی ، بهداشت شغلی و زيست محيطی در طی سال 88 و نيمه اول سال 89 را تشريح و برخی آمار و ارقام و حوادث و سير نزولی حوادث رخ داده طی 10 سال گذشته در صنعت برق آذربايجان را بيان داشت .وی همچنين اهداف کلان ، برنامه ها ، ميزان پيشرفت و تحقق برنامه ها در سيستم های ISO 14001 OHSAS 18001 , را به سمع حاضرين رساند .&lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;مهندس غلامی همچنين سياستهای صرفه جويي برق آذربايجان در مصرف منابع ، عملکرد شرکت در رابطه با پايش وضعيت جسمانی کارکنان و نيز برخی الزامات قانونی ، دستورالعملها ، مميزی و روشهای اجرايي انجام يافته در موضوع ايمنی ، بهداشت شغلی و زيست محيطی را نيز تشريح نمود .در ادامه جلسه مهندس ساعی مدير کل ستاد بحران استان آذربايجان شرقی ضمن گراميداشت هفته کاهش اثرات بلايای طبيعی ، گزارشی از فعاليت ها و اهداف اين ستاد در مديريت بحران استان را تشريح کرد .مشاور استاندار آذربايجانشرقی همچنين با اشاره به اينکه ستاد بحران استان از سال 83 همواره به عنوان استان برتر در برگزاری مانور زلزله معرفی شده است ، از کارگروه تخصصی تامين برق ، به عنوان يکی از کارگروه های فعال در بين 18 کارگروه تخصصی استان نام برد و ضمن تشکر از اهتمام جدی مجموعه مديران و متخصصان صنعت برق آذربايجان در موضوع « امداد و نجات و ايمنی » اظهار داشت که اخيرا" از سوی استاندار آذربايجانشرقی لوح تقديری نيز به مهندس بهاری وند مدير عامل برق آذربايجان در اين خصوص اعطاء گرديد .در ادامه مهندس همای راد معاون سازمان کار و امور اجتماعی استان در خصوص اهميت ايمن سازی محيط کار به ايراد سخنرانی پرداخت . همچنين مهندس اصولی تبريزی مدير عامل شرکت توزيع نيروی برق آذربايجانشرقی نيزگزارشی از عملکرد شرکت متبوع خود بخصوص در بخش توزيع برق در شهرها و روستاهای استان را ارائه نمود . در پايان اين مراسم مهندس بهاری وند مدير عامل شرکت برق منطقه ای آذربايجان طی سخنانی ضمن گراميداشت هفته کاهش اثرات بلايای طبيعی ، موضوع ايمنی و کاهش حوادث و اثرات بلايای طبيعی را موضوعی مهم و جهانی قلمداد کرد .وی ضمن تشکر از فعاليت تک تک کميته ها و کارگروههای ايمنی صنعت برق آذربايجان ، برلزوم افزايش سطح آگاهی پرسنل و مشترکين در بحث حوادث برق ، آموزش و تسری فرهنگ پيشگيری و مقابله با حوادث به بخشهای مختلف جامعه را امری ضروری قلمداد کرد .در پايان اين همايش از سوی مهندس بهاری وند و ساير مسئولين حاضر در همايش لوح های تقديری به مسئولين و اعضای کميته های نمونه ايمنی صنعت برق آذربايجان اعطاء گرديد و از تلاشهای اين عزيزان قدردانی شد .&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-1911827836152651085?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/1911827836152651085/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=1911827836152651085&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1911827836152651085'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/1911827836152651085'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_24.html' title='همايش روز ملی کاهش اثرات بلايای طبيعی در برق آذربايجان'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7431296817995534755</id><published>2010-10-19T11:54:00.005+03:30</published><updated>2010-11-10T18:53:56.479+03:30</updated><title type='text'>میلاد امام رضا (ع)</title><content type='html'>&lt;a href="http://lh6.ggpht.com/_OLhCddAhR2s/SA2GzhaagcI/AAAAAAAAARc/KUmrzR4ms2E/s512/DSC00710.JPG"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 351px; CURSOR: hand; HEIGHT: 231px; TEXT-ALIGN: center" alt="" src="http://lh6.ggpht.com/_OLhCddAhR2s/SA2GzhaagcI/AAAAAAAAARc/KUmrzR4ms2E/s512/DSC00710.JPG" border="0" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;در روز پنج‌شنبه سال 148 ه. امام رضا (ع) در مدينه طيبه به دنيا آمد. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;در روایت ولادت آن حضرت 11 ذي‌الحجه و 11 ربيع الاول نيز ذكر شده است. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;پدر آن حضرت موسي بن جعفر (ع) و مادرشان ام‌البنين نجمه (ع) است. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;نام مباركشان علي است، و كنيه آن حضرت ابوالحسن است، و كنيه خاصشان ابوعلي است. القاب حضرت سراج‌الله، نورالهدي، قره عين المومنين، مكيده الملحدين، كفو الملك، كافي الخلق، رب‌السرير، فاضل، صابر، وفي، صديق و رضي است. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;هنگامي كه آن حضرت به دنيا آمد پدرشان حضرت موسي بن جعفر (ع) دستور دادند فرزندشان را بياورند. آن حضرت را در پارچه سفيدي پيچيده و به خدمت پدر بردند. آن حضرت در گوش راست حضرت رضا (ع) اذان و در گوش چپ آن حضرت اقامه فرمود و آب فرات به كام مبارك آن حضرت ريخت و سپس او را به مادر مكرمه‌اش نجمه (ع) برگردانيدند.&lt;/span&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;ولادت با سعادت هشتمین اختر تابناک امامت و ولایت حضرت رضا(ع) را به تمام شیعیان جهان, خصوصا همکاران عزیزم, تبریک عرض می نمايم.&lt;/span&gt;&lt;/strong&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7431296817995534755?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7431296817995534755/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7431296817995534755&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7431296817995534755'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7431296817995534755'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_19.html' title='میلاد امام رضا (ع)'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://lh6.ggpht.com/_OLhCddAhR2s/SA2GzhaagcI/AAAAAAAAARc/KUmrzR4ms2E/s72-c/DSC00710.JPG' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8079855775704447309</id><published>2010-10-17T10:27:00.001+03:30</published><updated>2010-10-17T10:31:54.248+03:30</updated><title type='text'>Common Dangers Residential Electricians Encounter</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;p dir="ltr" align="left"&gt;Everyone knows that electricians run the a risk of being shocked. Many professional electricians get shocked but rarely does this kill them. Your reaction can be more dangerous than the shock itself. Receiving a shock at the top of an extension ladder might only numb your finger but if you overreact you could fall off the ladder and break your leg.&lt;br /&gt;An electrical shock occures when any part of your body touches 2 things;&lt;br /&gt;1) Something electrically hot. The copper in a hot wire, the metal bus bar in a panel, the metal part of your screw driver as it touches a hot screw on a circuit breaker.&lt;br /&gt;2) Something grounded. This can be the metal frame of an electrical panel, a steel post, wet concrete or something metal that is connected to the earth or grounded including a neutral which is also referred to as a "grounded conductor".&lt;br /&gt;The electricity passes in your body where you are touching the hot and out your body where you are touching the ground or something connected to the ground like a metal pipe or a metal column. If you touch the end of a wire with a hot, neutral and ground, you will feel the pain as electricity passes in and out your fingertip from the black wire to the ground wire or the grounded white neutral wire. The better the insulation the more safe you will become. Dry hands provide more insulation then wet hands. Rubber soled shoes provide more insulation than bare feet. Standing on dry wood while working on a hot panel is safer than standing on wet concrete.&lt;br /&gt;You can touch something electrically hot like a 20 amp metal wire conductor and not get shocked but only if you don't touch anything grounded. (the ground, water on the ground or any electrically conductive thing that is connected to the ground.)&lt;br /&gt;The higher the voltage the more dangerous. Getting shocked with standard residential voltages of 120 or 240 volts will hurt and can kill but it is not as dangerous as the higher commercial and utility voltages.&lt;br /&gt;In addition to being shocked, there are other dangers.You might also;&lt;br /&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;&lt;strong&gt;Cut&lt;/strong&gt;&lt;/span&gt; your finger with a knife while trying to strip off insulation.&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;Drill&lt;/span&gt;&lt;/strong&gt; into your hand or get your long hair ripped off by a spinning drill bit.&lt;br /&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;&lt;strong&gt;Fall&lt;/strong&gt;&lt;/span&gt; off a ladder or fall in a hole in the floor.&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;Step&lt;/span&gt;&lt;/strong&gt; through the ceiling sheet rock.&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;Slip&lt;/span&gt;&lt;/strong&gt; and fall on a plank being used as a ramp where stairs are not yet built.&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;Smash&lt;/span&gt;&lt;/strong&gt; your finger with your hammer while stapling a wire.&lt;br /&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;&lt;strong&gt;Stab&lt;/strong&gt;&lt;/span&gt; yourself on a nail sticking down thru the roof or wall.&lt;br /&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;&lt;strong&gt;Take a hit&lt;/strong&gt;&lt;/span&gt; from a falling object.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;Throw sparks&lt;/span&gt;&lt;/strong&gt; and destroy a hand tool when you cut a hot 14/2 with ground wire cable.&lt;br /&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;&lt;strong&gt;Twist&lt;/strong&gt;&lt;/span&gt; your arm or get knocked in the head by a powerful spinning drill handle. &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8079855775704447309?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8079855775704447309/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8079855775704447309&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8079855775704447309'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8079855775704447309'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/common-dangers-residential-electricians.html' title='Common Dangers Residential Electricians Encounter'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-3468520133741788753</id><published>2010-10-17T10:26:00.004+03:30</published><updated>2010-10-24T10:37:12.953+03:30</updated><title type='text'>لينك برخي از سازمان هاي بين المللي ايمني برق</title><content type='html'>&lt;div dir="ltr"&gt;&lt;/div&gt;&lt;div dir="ltr" align="left"&gt;&lt;a name="links"&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;&lt;strong&gt;&lt;span style="color:#ffff00;"&gt;Professional Organizational Links&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;&lt;div dir="ltr" align="left"&gt;&lt;a href="http://www.ansi.org/"&gt;&lt;span style="font-size:130%;"&gt;ANSI&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (American National Standards Institute)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.asse.org/"&gt;&lt;span style="font-size:130%;"&gt;ASSE&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (American Society of Safety Engineers)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.astm.org/"&gt;&lt;span style="font-size:130%;"&gt;ASTM&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (American Society for Testing and Materials)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.bcsp.com/"&gt;&lt;span style="font-size:130%;"&gt;BCSP&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (Board of Certified Safety Professionals)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.ieee.org/"&gt;&lt;span style="font-size:130%;"&gt;IEEE&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (Institute of Electrical and Electronics Engineers)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.nafe.org/"&gt;&lt;span style="font-size:130%;"&gt;NAFE&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (National Academy of Forensic Engineers)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.nfpa.org/"&gt;&lt;span style="font-size:130%;"&gt;NFPA&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (National Fire Protection Association)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.nsc.org/"&gt;&lt;span style="font-size:130%;"&gt;NSC&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (National Safety Council)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.nspe.org/"&gt;&lt;span style="font-size:130%;"&gt;NSPE&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (National Society of Professional Engineers)&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.osha.gov/"&gt;&lt;span style="font-size:130%;"&gt;OSHA&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt; (Occupational Safety&lt;/span&gt; and Health Administration) &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-3468520133741788753?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/3468520133741788753/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=3468520133741788753&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3468520133741788753'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/3468520133741788753'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_8830.html' title='لينك برخي از سازمان هاي بين المللي ايمني برق'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-6612064843017309498</id><published>2010-10-17T09:51:00.000+03:30</published><updated>2010-10-17T09:54:55.445+03:30</updated><title type='text'>Electrical Safety After a Disaster</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;/div&gt;&lt;p dir="ltr" align="left"&gt;Serious injury can result for anyone dealing with the aftermath of a major storm, tornado, or other disaster, so it's wise to be overly cautious.&lt;br /&gt;&lt;strong&gt;Tips&lt;/strong&gt;&lt;br /&gt;-Beware of outdoor hazards. Watch out for loose or dangling power lines, and report them immediately to proper authorities. It is not unusual in a disaster such as this for more people to be killed by carelessness in the aftermath than were killed by the event itself.&lt;br /&gt;-Be sure all electric and gas services are turned off before entering buildings for the first time.&lt;br /&gt;-Disconnect main switch and all circuits.&lt;br /&gt;-Remove covers from all outlets and fuses or multibreaker boxes and flush with clean water. Let dry and spray with contact cleaner/lubricant.&lt;br /&gt;-Watch for electrical shorts or live wires. Don't turn on any lights or appliances until an electrician has checked the system for short circuits.&lt;br /&gt;-Electric motors in appliances that have been flooded should be thoroughly cleaned and reconditioned before they are put back into service. &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-6612064843017309498?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/6612064843017309498/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=6612064843017309498&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6612064843017309498'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/6612064843017309498'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/electrical-safety-after-disaster.html' title='Electrical Safety After a Disaster'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-8374418731878196811</id><published>2010-10-17T09:13:00.000+03:30</published><updated>2010-10-17T09:15:23.307+03:30</updated><title type='text'>به منظور فرهنگ سازي وارتقاءسطح ايمني در بين كاركنان ، دوازدهمين همايش ايمني برق برگزار شد</title><content type='html'>&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;دوازدهمين همايش ايمني به منظور فرهنگ سازي وارتقاءسطح ايمني در بين كاركنان با حضور مدير عامل ،معاونين ، مديران وجمعي از اساتيد دانشگاه وجمع كثيري از كاركنان صنعت برق باختر  برگزار شد.به گزارش پایگاه خبری وزارت نیرو؛" آرش كردي "مدير عامل برق باختر ضمن تأكيد بر اهميت ايمني و لزوم رعايت آن به ويژه در صنعت برق گفت :  حدود 10درصد از تأسيسات و تجهيزات توليد ، انتقال وتوزيع انرژي الكتريكي كشور در شركت برق منطقه اي باختر در سطح سه استان مركزي ، همدان و لرستان مديريت مي شود .&lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;وي افزود : به منظور ارتقاء سطح ايمني در شركت برق منطقه اي باختر بر نامه هاي استراتژيك وبلند مدت راهبردي وعملياتي تدوين گرديده و پيوسته مورد كنترل وپايش قرار مي گيرند. کردی تصریح کرد :امروزه 4 راهكار در راستاي ارتقاءايمني مطرح است که از آن جمله می توان به برقراري سيستم كنترل اتوماتيك وموقعيت ياب حمل ونقل جاده اي، برقراري سيستم پاداش جهت كاركنان كه ايمني را رعايت می کنند، برقراري سيستم آموزش ايمني براي كاركنان و فرهنگ سازي در سازمان مبني بر ايمني قبل از انجام كار اشاره کرد. &lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;در اين همايش دكتر كاشانيان عضو هيأت علمي ومدرس دانشگاه امام حسين مطالبي در زمينه شناخت جايگاه ايمني در اركان سيستم حمل ونقل ارائه کرد.&lt;/span&gt;&lt;/div&gt;&lt;div dir="rtl" align="right"&gt;&lt;span style="font-size:130%;"&gt;همچنین در اين همايش موضوعاتي در خصوص،عوامل موثر در مديريت، حفاظت وايمني در حمل ونقل جاده اي ، سيستم ترمز ضد قفل ABS نيز توسط ديگر اساتيد دانشگاه و اساتيد سازمان آموزشي فني وحرفه اي استان مركزي مطرح شد.&lt;/span&gt; &lt;/div&gt;&lt;div dir="rtl" align="right"&gt;منبع : سايت خبري وزارت نيرو&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-8374418731878196811?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/8374418731878196811/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=8374418731878196811&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8374418731878196811'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/8374418731878196811'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_17.html' title='به منظور فرهنگ سازي وارتقاءسطح ايمني در بين كاركنان ، دوازدهمين همايش ايمني برق برگزار شد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-522409212440515755</id><published>2010-10-16T13:06:00.001+03:30</published><updated>2010-10-16T13:08:00.461+03:30</updated><title type='text'>شرايط محيطي و عامل انساني دو عامل ايجاد حوادث در محيط كار هستند</title><content type='html'>&lt;a href="http://www.irimlsa.ir/FixInfo/bazresikar/pages/esabati-semnan.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 250px; CURSOR: hand; HEIGHT: 221px; TEXT-ALIGN: center" alt="" src="http://www.irimlsa.ir/FixInfo/bazresikar/pages/esabati-semnan.jpg" border="0" /&gt;&lt;/a&gt;سمنان - مدير كل بازرسي كار وزارت كار و امور اجتماعي گفت: دلايل به وجود آمدن حوادث در محيط هاي كاري شرايط محيطي و عامل انساني است.&lt;br /&gt;'محمد اصابتي' روز پنجشنبه در همايش ايمني در كارگاههاي ساختماني سمنان با بيان اينكه طبق آمار ارائه شده توسط سازمان بين المللي كار عامل انساني و عوامل فني باعث حوادث در محيط هاي كاري را موجب مي شود افزود: عامل انساني 85 درصد از حوادث را ايجاد مي كند. وي با اشاره به روند صنعتي شدن و استفاده بيشتر از ماشين آلات در احداث ساختمانها حوادث نيز افزايش يافته است گفت: آگاهسازي نيروي كار از خطرات و قانونمند كردن استفاده از ابزار از عواملي هستند كه در كاهش ميزان حوادث تاثير گذارند. اصابتي افزود: فراهم كردن ابزار كار و ايمني، آموزش استفاده از ابزار و وسايل و نظارت از وظايف كارفرما است كه در نبود آموزش و نظارت حساسيت بيشتري ديده مي شود. وي اظهار داشت: طبق آمارها بيشترين فراواني حوادث براي نيروي كار 20 تا 29 سال اتفاق مي افتد. مدير كل بازرسي كار وزارت كار و امور اجتماعي گفت: توجه به ايمني و سلامت نيروي كار در حقيقت ارج نهادن به مقام انسانيت افراد است كه در دين مبين اسلام هم به آن توجه بسياري شده است. در اين همايش كه مهندسان و اعضاي سازمان نظام مهندسي ساختمان سمنان حضور داشتند كارگاه آموزشي كار در ارتفاع برگزار شد.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-522409212440515755?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/522409212440515755/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=522409212440515755&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/522409212440515755'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/522409212440515755'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_16.html' title='شرايط محيطي و عامل انساني دو عامل ايجاد حوادث در محيط كار هستند'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-2710390777321542864</id><published>2010-10-11T11:35:00.001+03:30</published><updated>2010-10-11T11:37:40.631+03:30</updated><title type='text'>اصلاحیه قانون کار برگشت خورد/ احتمال ارسال مستقیم لایحه به مجلس</title><content type='html'>&lt;span style="font-size:130%;"&gt;معاون وزیر کار از برگشت خوردن لایحه اصلاحیه قانون کار از دولت به وزارت کار برای بررسی دوباره و اعمال تغییرات جدید خبر داد و گفت: احتمال ارسال مستقیم این لایحه به مجلس توسط وزیر کار وجود دارد.&lt;br /&gt;حمید حاجی عبدالوهاب در گفتگو با مهر درباره آخرین اقدامات انجام شده در وزارت کار و امور اجتماعی برای اصلاح قانون کار و برنامه هایی که این وزارتخانه برای به روزرسانی برخی مواد قانون کار دارد، گفت: قبلا یک پیش نویسی توسط وزارت کار تهیه شده بود که بعدا در قالب لایحه در کمیسیونهای دولت بررسی شد.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;دلیل تعویق اصلاح قانون کار&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;معاون توسعه اشتغال و کارآفرینی وزارت کار با بیان دلیل تاخیر و وقفه در نهایی شدن اصلاحات قانون کار، اظهار داشت: وقتی دولت عوض می شود؛ معمولا لوایحی که در دستور بررسی است را دوباره به وزیر جدید ارجاع می دهند که اگر وی موافق باشد کار بررسی ادامه پیدا می کند و اگر نباشد اصلاحاتی صورت می پذیرد و کار مسیر خود را طی خواهد کرد.&lt;br /&gt;حاجی عبدالوهاب با تاکید بر اینکه وقفه ایجاد شده در بررسی اصلاحات قانون کار مربوط به جابه جایی دولتهای نهم و دهم بوده است، تصریح کرد: هم اکنون نیز تقریبا کار تدوین پیش نویس اصلاحیه قانون کار در وزارت کار در مراحل نهایی بوده و ویرایش جدیدی بر روی موارد مطرح شده در حال شکل گیری است.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;تدوین لایحه با ویرایش جدید&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;وی در پاسخ به این سئوال که رویکرد کلی اصلاحات چگونه است؟ گفت: نگاه کلی این است که قانون کار را در جهت بهبود فضای کسب و کار تغییر دهیم و اصلاح کنیم که هم منافع کارگر، کارفرما و دولت به صورت توامان با یکدیگر دیده و تامین شود.&lt;br /&gt;این مقام مسئول در وزارت کار افزود: لذا نگاه صنفی به آن نشده است که بگوییم تا حالا مجموعه قوانین به نفع کارگر بوده است و حالا برویم به سمت کارفرمایان، چون اصلا اینگونه نیست.&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#33ff33;"&gt;حذف نگاه صنفی از اصلاحیه قانون کار&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;به گفته عبدالوهاب، ایجاد سرمایه گذاری، پایداری آن، آسان شدن سرمایه گذاری، کاهش هزینه های سرمایه گذاری، کاهش قیمت تمام شده کالاها و خدمات از موضوعاتی است که سعی شده در اصلاح قانون کار مورد توجه واقع شود.&lt;br /&gt;معاون وزیر کار و امور اجتماعی با تاکید بر اینکه اصلاحات مطرح شده برای قانون کار، مشارکت شرکای اجتماعی را نیز به همراه داشته است، گفت: البته آنها اظهار نظرهایی را از قبل مطرح و به جمع بندی رسیده بودند که به نوعی در پیش نویس اصلاح قانون کار لحاظ شد.وی تصریح کرد: در هر حال پیش نویس هنوز بسته نشده است و اگر آنها (کارگران و کارفرمایان) پیشنهاداتی را داشته باشند مورد توجه قرار می گیرد.&lt;br /&gt;حاجی عبدالوهاب خاطر نشان کرد: در دوره جدید فعالیت وزارت کار پیش نویس جدیدی با رویکرد و نگاه جدید تهیه شد که بعد از تکمیل به دولت خواهد رفت و به محض آماده شدن نیز به صورت یک لایحه تحویل مجلس می شود.&lt;br /&gt;معاون وزیر کار تاکید کرد: البته شاید ارسال پیش نویس اصلاح قانون کار خیلی نیاز به مصوبه دوباره دولت نداشته باشد و با تفویض یک اختیار ویژه، لایحه به مجلس برود ولی فعلا چون پیش نویس از سوی دولت به وزارت کار ارجاع شده است، نحوه ارسال دوباره آن مشخص نیست.وی افزود: اگر جمع بندی پیش نویس اصلاح قانون کار به اتمام برسد ممکن است بتوان از اختیار قانون اساسی برای کمیسیون اجتماعی دولت و یا خود شخص وزیر استفاده کرد و لایحه را مستقیما برای تسریع در کار بررسی به مجلس فرستاد. &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-2710390777321542864?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/2710390777321542864/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=2710390777321542864&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2710390777321542864'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/2710390777321542864'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_11.html' title='اصلاحیه قانون کار برگشت خورد/ احتمال ارسال مستقیم لایحه به مجلس'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7499792773600170432</id><published>2010-10-06T15:36:00.003+03:30</published><updated>2010-10-17T09:58:20.570+03:30</updated><title type='text'>Basic safety from unsafe electricity</title><content type='html'>&lt;div dir="ltr" align="left"&gt;The maintenance of just about any building or home's electrical system is important. Mishaps, injuries and also death are causes which could be linked to incidents and unmaintained electrical system. Always bear in mind that electricity may wipe out virtually any living being immediately dependant upon the current that's flowing or consists. To stay away from and steer clear of such incidents, a professional need to often check the building's electricity cable wires or system.&lt;br /&gt;Wrong installation of wirings and electric cables are the widespread reasons behind electrocution as well as other incidents which are connected to electricity. The proper tools and gadgets should usually be applied when within the area of construction. One should never be too reckless and work as if they comprehend it all about electricity as a basic or freak accident may very easily take their own lives. Utilizing the proper tools whenever modifying or correcting many wiring is also the very best prevention for making errors in a construction site. An instrument that isn't suit for a certain difficulty can not and can never repair the issue.&lt;br /&gt;Basic safety from electricity is extremely vital to almost any developed buildings, from the beginning of the construction to the installing of cable wires for electricity flow. Working with a expert check the installation plans of electrical system will probably be really useful for the construction workers and even for the future renters of the building. The specialist that may perform the assessment of electrical wires and electricity flow to building must be also conscious of the risk that may possibly occur within the construction sites and should put on a suit which will avoid him from getting electrocuted.&lt;br /&gt;Even if obtaining the electrical systems checked out regularly, renters of the building or employees and staffs which are doing work within the mentioned structure must often keep to the directions and manuals which might be presented to them by the building's technical workers. Tenants along with other people which are occupying the building should always be conscious of wires which have been loosened inadvertently or deliberately. The individuals within the building should usually assume whenever they observe a cut cable or wire that it really has electricity flowing through it and should not touch. A phone connection which will be linked to directly to the maintenance personnel must be also quickly accessible should any one of this particular problem happen.&lt;br /&gt;Seminars as well as other safe practices programs must often be held each year or as frequent as possible concerning the electricity risks and electrical mishaps that might take place within the building. Protection need to constantly come first before everything else.&lt;br /&gt;The design of the building along with other suggestions coming from authorities that specializes in electricity circuits and electrical systems need to usually be considered. Planning ahead is far better and making basic safety plans about security ought to always be the first to be talked about.&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7499792773600170432?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7499792773600170432/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7499792773600170432&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7499792773600170432'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7499792773600170432'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/basic-safety-from-unsafe-electricity.html' title='Basic safety from unsafe electricity'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7917147834127886269</id><published>2010-10-06T15:30:00.003+03:30</published><updated>2010-10-06T15:37:17.604+03:30</updated><title type='text'>برق، جان یک کارگر را گرفت</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/parameters/ohsms.meedc/modules/admin_news/store_folder/construction-site-accident.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 180px; CURSOR: hand; HEIGHT: 180px; TEXT-ALIGN: center" alt="" src="http://ohsms.meedc.ir/parameters/ohsms.meedc/modules/admin_news/store_folder/construction-site-accident.jpg" border="0" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;به گزارش خبرنگار پايگاه خبري 125، با تماس شهروندان با سامانه 125 ستاد فرماندهي آتش‌نشاني تهران بي‌درنگ آتش‌نشانان ايستگاه 81 آتش‌نشاني را در ساعت 16:47 دقيقه روز گذشته به محل حادثه در محله نعمت آباد خيابان نور روانه كرد.&lt;br /&gt;رضا صامت رييس ايستگاه 81 آتش‌نشاني كه در محل حادثه حضور داشت گفت: آتش‌نشانان بلافاصله شخصي كه در طبقه دوم يك ساختمان نيمه كاره مشغول كار بود و ميلگرد آهني داخل دستش با شبكه برق فشار قوي برخورد كرده بود را به محل امن انتقال دادند و با تشخيص اورژانس حاضر در محل اين كارگر جوان براثر برق گرفتگي فوت شده بود.&lt;br /&gt;منبع : سايت آتش نشاني شهرداري تهران&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7917147834127886269?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7917147834127886269/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7917147834127886269&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7917147834127886269'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7917147834127886269'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post_06.html' title='برق، جان یک کارگر را گرفت'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-5426751540222490286</id><published>2010-10-06T08:02:00.001+03:30</published><updated>2010-10-06T08:04:48.602+03:30</updated><title type='text'>Electric shock from welding</title><content type='html'>&lt;div dir="ltr" align="left"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 275px; CURSOR: hand; HEIGHT: 160px; TEXT-ALIGN: center" alt="" src="http://www.msha.gov/accident_prevention/tips/images/shock1.gif" border="0" /&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;Electric shock from welding can kill!! Any electric welder, AC or DC, has the power to cause electrocution if the electrode touches your bare skin while you are grounded.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;Two recent accidents have occurred when employees were using an electric arc welder. They received electrical shocks resulting in one fatality and a near-fatality.&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;color:#33ff33;"&gt;To avoid electric shocks and possible electrocution, personnel should take the following precautions:&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;Wear dry, insulated gloves in good condition and protective clothing. (Change as necessary to keep dry)&lt;br /&gt;Insulate yourself from the workpiece and ground by wearing rubber soled shoes or stand on a dry insulated mat. Do not touch the ground with any other part of your body.&lt;br /&gt;Use fully insulated electrode holders.&lt;br /&gt;Do not use worn, damaged, undersized or poorly spliced cables.&lt;br /&gt;Do not wrap cables carrying current around your body.&lt;br /&gt;Do not touch an energized electrode with bare hands.&lt;br /&gt;Turn off all equipment when not in use.&lt;br /&gt;Use only well maintained equipment. Repair or replace damaged parts before further use.&lt;br /&gt;Wet working conditions should be avoided. Even a person's perspiration can lower the body's resistance to electrical shock.&lt;br /&gt;The avoidance of electrical shock is largely within the control of the welder. Therefore, it is especially important that the welder be thoroughly trained on safe welding procedures. Safe procedures must be observed at all times when working with equipment having voltages necessary for arc welding. These voltages can be dangerous to life. Even mild shocks can cause involuntary muscular contractions. &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-5426751540222490286?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/5426751540222490286/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=5426751540222490286&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5426751540222490286'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/5426751540222490286'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/electric-shock-from-welding.html' title='Electric shock from welding'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-8116238656716228153.post-7888254167181980806</id><published>2010-10-02T09:12:00.003+03:30</published><updated>2010-10-02T11:36:27.694+03:30</updated><title type='text'>راه اندازي سايت ايمني و بهداشت شركت توزيع نيروي برق شهرستان مشهد</title><content type='html'>&lt;a href="http://ohsms.meedc.ir/upload/editor/2/Image/pooster%20imeny2.jpg"&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 213px; CURSOR: hand; HEIGHT: 246px; TEXT-ALIGN: center" alt="" src="http://ohsms.meedc.ir/upload/editor/2/Image/pooster%20imeny2.jpg" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;به منظور اطلاع رساني و آگاه سازي مردم ، مشتركين و كليه ذي نفعان ، شركت توزيع نيروي برق شهرستان مشهد، اقدام به راه اندازي سايت ويژه ايمني و بهداشت شغلي نموده كه تمام فعاليت ها و همچنين توصيه هاي لازم، مرتبط در خصوص آداب كار با تجهيزات الكتريكي و كار در جوار شبكه ها و تأسيسات برق در آن ثبت گرديده است.&lt;br /&gt;جا دارد در اينجا از معاونت محترم برنامه ريزي و مهندسي و دفتر محترم برنامه ريزي و بودجه آن شركت كه در راه اندازي اين سايت نقش بسزايي داشتند تشكر و قدرداني نمايم.&lt;br /&gt;آدرس اين سايت به شرح ذيل است :&lt;br /&gt;&lt;a href="http://ohsms.meedc.ir/"&gt;&lt;span style="font-size:130%;"&gt;&lt;strong&gt;http://ohsms.meedc.ir&lt;/strong&gt;&lt;/span&gt;&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/8116238656716228153-7888254167181980806?l=electric-safety.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://electric-safety.blogspot.com/feeds/7888254167181980806/comments/default' title='نظرات پيام'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=8116238656716228153&amp;postID=7888254167181980806&amp;isPopup=true' title='0 نظر'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7888254167181980806'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/8116238656716228153/posts/default/7888254167181980806'/><link rel='alternate' type='text/html' href='http://electric-safety.blogspot.com/2010/10/blog-post.html' title='راه اندازي سايت ايمني و بهداشت شركت توزيع نيروي برق شهرستان مشهد'/><author><name>رضا نيك پيام</name><uri>http://www.blogger.com/profile/08260135195306922340</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='25' height='32' src='http://4.bp.blogspot.com/_o6rpep5dvIA/TQq_HMF_geI/AAAAAAAAFDY/QmI2oNzGcSg/S220/imagesCAWIH38O.jpg'/></author><thr:total>0</thr:total></entry></feed>
